LF412-N 数据资料 dataSheet 下载
... the full temperature range. If the amplifier is forced to drive heavier load currents, however, an increase in input offset voltage may occur on the negative voltage swing and finally reach an active current limit on both positive and negative swings. Precautions should be taken to ensure that the p ...
... the full temperature range. If the amplifier is forced to drive heavier load currents, however, an increase in input offset voltage may occur on the negative voltage swing and finally reach an active current limit on both positive and negative swings. Precautions should be taken to ensure that the p ...
AM512B - RLS encoders
... Pin 37 (Agndi) is an internally generated reference voltage. It is generated with a Vdd/Vss resistor divider. The resistors values are 20 kΩ and 30 kΩ. The reference voltage is 3 V typically (3/5 of power supply voltage). Agndi must be connected to an external 100 nF capacitor. The reference voltage ...
... Pin 37 (Agndi) is an internally generated reference voltage. It is generated with a Vdd/Vss resistor divider. The resistors values are 20 kΩ and 30 kΩ. The reference voltage is 3 V typically (3/5 of power supply voltage). Agndi must be connected to an external 100 nF capacitor. The reference voltage ...
Analog/digital conversions
... Logic inputs and outputs meet both MOS and TTL voltage level specifications Works with 2.5V (LM336) voltage reference ...
... Logic inputs and outputs meet both MOS and TTL voltage level specifications Works with 2.5V (LM336) voltage reference ...
Safe Simple Complete Solutions for Renewable Energy
... Inverters produce higher fault currents with greater potential for short circuits. Our high speed fuses protect sensitive power switching electronic components in the inverter. We offer the right body style to meet global needs, as well as lower watts loss, enabling these fuses to operate with the g ...
... Inverters produce higher fault currents with greater potential for short circuits. Our high speed fuses protect sensitive power switching electronic components in the inverter. We offer the right body style to meet global needs, as well as lower watts loss, enabling these fuses to operate with the g ...
voltage - Siemens
... 11. SPD shall be designed to withstand a maximum continuous operating voltage (MCOV) of not less than 115% of nominal RMS voltage. 12. SPD shall have a minimum EMI/RFI filtering of - 50dB at 100kHz. 13. SPD shall provide a minimum of visual and audible diagnostic monitoring for each phase of protect ...
... 11. SPD shall be designed to withstand a maximum continuous operating voltage (MCOV) of not less than 115% of nominal RMS voltage. 12. SPD shall have a minimum EMI/RFI filtering of - 50dB at 100kHz. 13. SPD shall provide a minimum of visual and audible diagnostic monitoring for each phase of protect ...
Chap3
... carrier-depletion region (shown in the figure below) because the two extremes create a potential difference to result. This is in the form of a barrier that holes and electrons must cross in order to create a current. Thus, it can be seen that the current ID depends on this barrier voltage (which is ...
... carrier-depletion region (shown in the figure below) because the two extremes create a potential difference to result. This is in the form of a barrier that holes and electrons must cross in order to create a current. Thus, it can be seen that the current ID depends on this barrier voltage (which is ...
AP2552-53(A) - Diodes Incorporated
... Thermal protection prevents the IC from damage when the die temperature exceeds safe margins. This mainly occurs when heavy-overload or short-circuit faults are present for extended periods of time. The AP2552/53 AND AP2552A/53A implements a thermal sensing to monitor the operating junction temperat ...
... Thermal protection prevents the IC from damage when the die temperature exceeds safe margins. This mainly occurs when heavy-overload or short-circuit faults are present for extended periods of time. The AP2552/53 AND AP2552A/53A implements a thermal sensing to monitor the operating junction temperat ...
MAX038 - ResearchGate
... When the MAX038’s frequency is controlled by a voltage source (VIN) in series with a fixed resistor (RIN), the output frequency is a direct function of VIN as shown in the above equations. Varying VIN modulates the oscillator frequency. For example, using a 10kΩ resistor for RIN and sweeping VIN fro ...
... When the MAX038’s frequency is controlled by a voltage source (VIN) in series with a fixed resistor (RIN), the output frequency is a direct function of VIN as shown in the above equations. Varying VIN modulates the oscillator frequency. For example, using a 10kΩ resistor for RIN and sweeping VIN fro ...
AM512B - angular magnetic encoder IC
... Pin 37 (Agndi) is an internally generated reference voltage. It is generated with a Vdd/Vss resistor divider. The resistors values are 20 kΩ and 30 kΩ. The reference voltage is 3 V typically (3/5 of power supply voltage). Agndi must be connected to an external 100 nF capacitor. The reference voltage ...
... Pin 37 (Agndi) is an internally generated reference voltage. It is generated with a Vdd/Vss resistor divider. The resistors values are 20 kΩ and 30 kΩ. The reference voltage is 3 V typically (3/5 of power supply voltage). Agndi must be connected to an external 100 nF capacitor. The reference voltage ...
FEATURES DESCRIPTION D
... to the positive rail, so that with even a small 33µF coupling capacitor, the output is well outside the saturation limits of the OPA360. Figure 7 shows the output swing of the OPA360, operated on 3.0V supplies, with a 22µF sag correction capacitor and a 33µF output coupling capacitor. The test signa ...
... to the positive rail, so that with even a small 33µF coupling capacitor, the output is well outside the saturation limits of the OPA360. Figure 7 shows the output swing of the OPA360, operated on 3.0V supplies, with a 22µF sag correction capacitor and a 33µF output coupling capacitor. The test signa ...
The Montana Consumer Guide to Grid-Interactive Solar Photovoltaic
... Each solar PV cell typically produces between one-two watts of power. Cells are connected together and form what is called a module or panel. Modules are then wired together to form the solar array. The PV cells within modules are covered with a protective coating for safety and durability purposes. ...
... Each solar PV cell typically produces between one-two watts of power. Cells are connected together and form what is called a module or panel. Modules are then wired together to form the solar array. The PV cells within modules are covered with a protective coating for safety and durability purposes. ...
IF 1442 Revision 4
... continued lighting performance. To clean, wipe the refractor with a clean, damp cloth. If this is not sufficient, use a mild soap or a liquid cleaner such as Collinite NCF or Duco #7. Do not use an abrasive, strong alkaline, or acid cleaner. ...
... continued lighting performance. To clean, wipe the refractor with a clean, damp cloth. If this is not sufficient, use a mild soap or a liquid cleaner such as Collinite NCF or Duco #7. Do not use an abrasive, strong alkaline, or acid cleaner. ...
MAX4644 High-Speed, Low-Voltage, 4 SPDT CMOS Analog Switch ,
... Applications Information The MAX4644 operates from a single supply ranging from +1.8V to +5.5V. The device is guaranteed to be functional over that supply range, but TTL/CMOS compatibility is only valid for operation using a +5V supply. All voltage levels are referenced to GND. Positive and negative ...
... Applications Information The MAX4644 operates from a single supply ranging from +1.8V to +5.5V. The device is guaranteed to be functional over that supply range, but TTL/CMOS compatibility is only valid for operation using a +5V supply. All voltage levels are referenced to GND. Positive and negative ...
TM-35XJC, TM-35XJF, TM-35XKC & TM-35XKF Panel Temperature Meters 3 1/2 Digit 0.48” LCD
... The differential input feature of the TM-35X facilitates temperature measurement using grounded thermocouples. In this configuration, an indirect ground return path is still required to prevent the common mode range of the inputs from being exceeded, but the circuit differs from the single-ended con ...
... The differential input feature of the TM-35X facilitates temperature measurement using grounded thermocouples. In this configuration, an indirect ground return path is still required to prevent the common mode range of the inputs from being exceeded, but the circuit differs from the single-ended con ...
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
... which the exemptions apply. If only some of the exemptions are listed, market participants will not be able to rely on this subsection to determine applicability and may not refer back to this subsection when reviewing the specific requirements. Therefore, the individual subsections from which some ...
... which the exemptions apply. If only some of the exemptions are listed, market participants will not be able to rely on this subsection to determine applicability and may not refer back to this subsection when reviewing the specific requirements. Therefore, the individual subsections from which some ...
MAX4561/MAX4568/MAX4569 ±15kV ESD-Protected, Low-Voltage, SPDT/SPST, CMOS Analog Switches General Description
... because unless the supplies are very carefully decoupled through low-ESR capacitors, the ESD current through the diode clamp could cause a significant spike in the supplies. This may damage or compromise the reliability of any other chip powered by those same supplies. There are diodes from NC/NO to ...
... because unless the supplies are very carefully decoupled through low-ESR capacitors, the ESD current through the diode clamp could cause a significant spike in the supplies. This may damage or compromise the reliability of any other chip powered by those same supplies. There are diodes from NC/NO to ...
Electrical
... • Damaged tools overheating • Lack of overcurrent protection • Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall ...
... • Damaged tools overheating • Lack of overcurrent protection • Wire insulation melting, which may cause arcing and a fire in the area where the overload exists, even inside a wall ...
XQ5200 Solar Taurus 60, T7300S
... Anti-condensation space heaters 300% short circuit capability for 10 seconds Overload capacity per NEMA: 150% rated current for 1 minute 110% for 2 hours ...
... Anti-condensation space heaters 300% short circuit capability for 10 seconds Overload capacity per NEMA: 150% rated current for 1 minute 110% for 2 hours ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.