Model HPX-10 Series - Cumulus Soaring, Inc.
... Do not remove cover. There are no user serviceable parts inside. Refer service to qualified service personnel. C Connect the battery charger directly to a grounding receptacle. An adaptor should not be used with this unit. This unit is equipped with a power plug having an equipment grounding conduct ...
... Do not remove cover. There are no user serviceable parts inside. Refer service to qualified service personnel. C Connect the battery charger directly to a grounding receptacle. An adaptor should not be used with this unit. This unit is equipped with a power plug having an equipment grounding conduct ...
ppt_ch16
... maximum potential difference of dc voltage that can be applied without puncturing the dielectric. A voltage rating higher than the potential difference applied provides a safety factor for long life in service. The breakdown rating is lower for ac voltage because of the internal heat produced by ...
... maximum potential difference of dc voltage that can be applied without puncturing the dielectric. A voltage rating higher than the potential difference applied provides a safety factor for long life in service. The breakdown rating is lower for ac voltage because of the internal heat produced by ...
Hd1800
... PROTECT LED can come on under 3 different conditions (when this happens, both channels are muted and the speaker relays disconnect the speakers); 1) During power-up, the amplifier stays in a muted state for approx. 3 sec until it determines that everything is functioning normally (no output shorts o ...
... PROTECT LED can come on under 3 different conditions (when this happens, both channels are muted and the speaker relays disconnect the speakers); 1) During power-up, the amplifier stays in a muted state for approx. 3 sec until it determines that everything is functioning normally (no output shorts o ...
Data Sheet AFBR-709SMZ 10Gb Ethernet, 850 nm, 10GBASE-SR/SW, SFP+ Transceiver
... Due to its shielded design, the EMI immunity of the AFBR-709SMZ exceeds typical industry standards. ...
... Due to its shielded design, the EMI immunity of the AFBR-709SMZ exceeds typical industry standards. ...
TBU-KE Series
... voltage surges in DC biased equipment, as shown in the figure below. Diode D1 prevents reverse voltage surges from damaging the equipment, and the TBU® protector prevents any positive surges from causing damage. An overvoltage protection device, such as an MOV, may be used to provide additional over ...
... voltage surges in DC biased equipment, as shown in the figure below. Diode D1 prevents reverse voltage surges from damaging the equipment, and the TBU® protector prevents any positive surges from causing damage. An overvoltage protection device, such as an MOV, may be used to provide additional over ...
MAX-M8 - u-blox
... certified sites, and fully tested on a system level. Qualification tests are performed as stipulated in the ISO16750 standard: “Road vehicles – Environmental conditions and testing for electrical and electronic equipment”. MAX-M8 modules are available in three product variants: ...
... certified sites, and fully tested on a system level. Qualification tests are performed as stipulated in the ISO16750 standard: “Road vehicles – Environmental conditions and testing for electrical and electronic equipment”. MAX-M8 modules are available in three product variants: ...
CD4069, CD4069-SMD Inverter Circuits
... wide power supply operating range, low power consumption, high noise immunity, and symmetric controlled rise and fall times. ...
... wide power supply operating range, low power consumption, high noise immunity, and symmetric controlled rise and fall times. ...
MAX9218 27-Bit, 3MHz-to-35MHz DC-Balanced LVDS Deserializer General Description
... The MAX9218 DC-balanced deserializer operates at a parallel clock frequency of 3MHz to 35MHz, deserializing video data to the RGB_OUT[17:0] outputs when the data enable output DE_OUT is high, or control data to the CNTL_OUT[8:0] outputs when DE_OUT is low. The video phase words are decoded using 2 o ...
... The MAX9218 DC-balanced deserializer operates at a parallel clock frequency of 3MHz to 35MHz, deserializing video data to the RGB_OUT[17:0] outputs when the data enable output DE_OUT is high, or control data to the CNTL_OUT[8:0] outputs when DE_OUT is low. The video phase words are decoded using 2 o ...
Electron emission from lead–zirconate–titanate ceramics
... FIG. 4. Anode voltage ~top trace! and gap current ~bottom trace! for two delays ~upper: 165 ns, lower: 1.2 ms!. ...
... FIG. 4. Anode voltage ~top trace! and gap current ~bottom trace! for two delays ~upper: 165 ns, lower: 1.2 ms!. ...
Liebert APM UPS 15-45kVA and 15-90kVA Guide
... when overload capacity is exceeded. 2.2.2.3 Fault Clearing and Current Limit The inverter shall be capable of supplying an overload current of 150% of its full-load rating for one minute. For greater currents or longer time duration, the inverter shall have electronic current-limiting protection to ...
... when overload capacity is exceeded. 2.2.2.3 Fault Clearing and Current Limit The inverter shall be capable of supplying an overload current of 150% of its full-load rating for one minute. For greater currents or longer time duration, the inverter shall have electronic current-limiting protection to ...
NB3H83905CDGEVB Evaluation Board User's Manual •
... OUTPUT VOLTAGE LEVELS WILL BE OFFSET. With this split supply, the device outputs will be parallel terminated by the oscilloscope (or frequency counter) input module’s internal 50 Ohms to GND impedance. ...
... OUTPUT VOLTAGE LEVELS WILL BE OFFSET. With this split supply, the device outputs will be parallel terminated by the oscilloscope (or frequency counter) input module’s internal 50 Ohms to GND impedance. ...
16972 - Electrical Starting and Testing by Contractor`s Testing Agent
... Air Breakers: Prior to carrying out hipot test, ensure all surrounding primary connections to main equipment are properly grounded and isolated. ...
... Air Breakers: Prior to carrying out hipot test, ensure all surrounding primary connections to main equipment are properly grounded and isolated. ...
The GEOSAT Follow-on (GFO) Altimeter
... detector. The power detector provides a DC voltage proportional to the output power, which adjusts the ALC attenuator in the low-power amplifier. Commonly used methods, for pulsed operation of microwave GaAs FET devices, are gate switching and drain switching. Gate switching involves changing the ga ...
... detector. The power detector provides a DC voltage proportional to the output power, which adjusts the ALC attenuator in the low-power amplifier. Commonly used methods, for pulsed operation of microwave GaAs FET devices, are gate switching and drain switching. Gate switching involves changing the ga ...
Animation of Power Converters and Electrical Drives
... Teaching and understanding Power Electronics and Electrical Drives have been done with the use of books and the blackboard. Many of us will remember the times drawing the basic waveforms of converter operation on paper while keeping the state of the converter in mind. Simulation made a change here, ...
... Teaching and understanding Power Electronics and Electrical Drives have been done with the use of books and the blackboard. Many of us will remember the times drawing the basic waveforms of converter operation on paper while keeping the state of the converter in mind. Simulation made a change here, ...
Analogue Instruments - Crompton Instruments
... /4" spade terminals available for models E243 and E244 Up to 95% RH (non condensing) 3kV RMS for 1 minute 1.0/1.2/1.5/2.5/5/6 and decade multiples thereof x 1.2 continuous x 10 for 5 seconds x 1.2 continuous x 2 for 5 seconds 23°C. Calibration at other temperatures available on request -20°C to +60° ...
... /4" spade terminals available for models E243 and E244 Up to 95% RH (non condensing) 3kV RMS for 1 minute 1.0/1.2/1.5/2.5/5/6 and decade multiples thereof x 1.2 continuous x 10 for 5 seconds x 1.2 continuous x 2 for 5 seconds 23°C. Calibration at other temperatures available on request -20°C to +60° ...
B25668A6107A375 - uri=media.digikey
... certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of ou ...
... certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of ou ...
MAX4986 Evaluation Kit Evaluates: General Description Features
... The characterization circuit is provided as a separate test circuit for eye diagram evaluation of the MAX4986. The characterization circuit section allows for detailed frequency analysis of a single channel. All channels have similar performance by design. This circuit provides differential SMA inpu ...
... The characterization circuit is provided as a separate test circuit for eye diagram evaluation of the MAX4986. The characterization circuit section allows for detailed frequency analysis of a single channel. All channels have similar performance by design. This circuit provides differential SMA inpu ...
1771-2.13, Allen-Bradley Analog Input Module (12
... The incoming data in each channel word has the option of appearing at the processor in either BCD or binary format. If the BCD format is selected, the processor can directly manipulate this value in comparisons or arithmetic functions, but is limited to a resolution range of 000 to 999. The binary o ...
... The incoming data in each channel word has the option of appearing at the processor in either BCD or binary format. If the BCD format is selected, the processor can directly manipulate this value in comparisons or arithmetic functions, but is limited to a resolution range of 000 to 999. The binary o ...
Folha de dados do detector de duto para ar
... The optical smoke switches of the ventilation smoke switch systems LRS 01, LRS 02 and LRS 03 are RS-Bus-compatible and also compatible with the smoke switch status display RZA 142. The communication interface (smoke switch PIN 3) is used to transmit the «operation», «dirty», «fault» and «alarm» stat ...
... The optical smoke switches of the ventilation smoke switch systems LRS 01, LRS 02 and LRS 03 are RS-Bus-compatible and also compatible with the smoke switch status display RZA 142. The communication interface (smoke switch PIN 3) is used to transmit the «operation», «dirty», «fault» and «alarm» stat ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.