Self-test GFCI with wire leads spec sheet
... Manually depress TEST button to trip device. Amber light should come ON • If Amber light does not come ON, check if there is power to the branch • If Amber light does come ON, manually depress the RESET button to restore power to the device • If GFCI does not reset, replace GFCI • If GFCI does r ...
... Manually depress TEST button to trip device. Amber light should come ON • If Amber light does not come ON, check if there is power to the branch • If Amber light does come ON, manually depress the RESET button to restore power to the device • If GFCI does not reset, replace GFCI • If GFCI does r ...
INDIANA UNIVERSITY - PURDUE UNIVERSITY FORT WAYNE DEPARTMENT OF ENGINEERING
... Wayne Combustion Systems (WCS) builds burners for oven and furnace applications that require a control circuit to regulate the combustion fan and gas valve of the burner to maintain a desired temperature. The current control board is built and owned by another company, which increases the cost of th ...
... Wayne Combustion Systems (WCS) builds burners for oven and furnace applications that require a control circuit to regulate the combustion fan and gas valve of the burner to maintain a desired temperature. The current control board is built and owned by another company, which increases the cost of th ...
2005 Code Changes
... placed in the test cell. This was a 480 volt, three phase system with an available three phase shortcircuit current of 22,600 symmetrical rms amperes. A non current-limiting overcurrent protective device was the nearest upstream protective device. An arcing fault was initiated in a combination motor ...
... placed in the test cell. This was a 480 volt, three phase system with an available three phase shortcircuit current of 22,600 symmetrical rms amperes. A non current-limiting overcurrent protective device was the nearest upstream protective device. An arcing fault was initiated in a combination motor ...
TPS62420-Q1 数据资料 dataSheet 下载
... The TPS62420 device is a synchronous dual step-down dc-dc converter optimized for battery-powered portable applications. It provides two independent output voltage rails powered by 1-cell Li-Ion or 3-cell NiMH/NiCD batteries. The device is also suitable to operate from a standard 3.3-V or 5-V voltag ...
... The TPS62420 device is a synchronous dual step-down dc-dc converter optimized for battery-powered portable applications. It provides two independent output voltage rails powered by 1-cell Li-Ion or 3-cell NiMH/NiCD batteries. The device is also suitable to operate from a standard 3.3-V or 5-V voltag ...
PDF
... The dielectric coolant shall be listed less-flammable fluid meeting the requirements of National Electrical Code Section 450-23 and the requirements of the National Electrical Safety Code (IEEE Std C2™-2002 standard), Section 15. The dielectric coolant shall be non-toxic*, non-bioaccumulating and be ...
... The dielectric coolant shall be listed less-flammable fluid meeting the requirements of National Electrical Code Section 450-23 and the requirements of the National Electrical Safety Code (IEEE Std C2™-2002 standard), Section 15. The dielectric coolant shall be non-toxic*, non-bioaccumulating and be ...
Word
... The dielectric coolant shall be listed less-flammable fluid meeting the requirements of National Electrical Code Section 450-23 and the requirements of the National Electrical Safety Code (IEEE Std C2™-2002 standard), Section 15. The dielectric coolant shall be non-toxic*, non-bioaccumulating and be ...
... The dielectric coolant shall be listed less-flammable fluid meeting the requirements of National Electrical Code Section 450-23 and the requirements of the National Electrical Safety Code (IEEE Std C2™-2002 standard), Section 15. The dielectric coolant shall be non-toxic*, non-bioaccumulating and be ...
Nine Series Effects (AD-9P, VOP-9, OSD-9, OOD-9)
... ●Vintage Overdrive Pro VOP9 adds natural and warm nuance to your guitar sound like that of a good vintage amp. Specially designed circuit reacts precisely to every fingering or picking nuance with minimal compression. ●VOP9 combines functions of clean booster and overdrive. With Drive Control level ...
... ●Vintage Overdrive Pro VOP9 adds natural and warm nuance to your guitar sound like that of a good vintage amp. Specially designed circuit reacts precisely to every fingering or picking nuance with minimal compression. ●VOP9 combines functions of clean booster and overdrive. With Drive Control level ...
ADP1870 英文数据手册DataSheet 下载
... The ADP1870/ADP1871 are versatile current-mode, synchronous step-down controllers that provide superior transient response, optimal stability, and current-limit protection by using a constant on-time, pseudo-fixed frequency with a programmable currentlimit, current-control scheme. In addition, these ...
... The ADP1870/ADP1871 are versatile current-mode, synchronous step-down controllers that provide superior transient response, optimal stability, and current-limit protection by using a constant on-time, pseudo-fixed frequency with a programmable currentlimit, current-control scheme. In addition, these ...
22B-QS001G-EN-P PowerFlex 40 Adjustable Frequency AC Drive
... intended for qualified drive service personnel only. For detailed PowerFlex 40 information including EMC instructions, application considerations and related precautions, refer to the PowerFlex 40 User Manual, Publication 22B-UM001… at www.rockwellautomation.com/literature. ...
... intended for qualified drive service personnel only. For detailed PowerFlex 40 information including EMC instructions, application considerations and related precautions, refer to the PowerFlex 40 User Manual, Publication 22B-UM001… at www.rockwellautomation.com/literature. ...
16230 Emergency Generator
... Specification. Insulation shall meet NEMA standards for Class F, in addition to the quality assurance requirements indicated above.. Maximum temperature rise shall not exceed 130 degrees C. Generator design shall prevent potentially damaging shaft currents. ...
... Specification. Insulation shall meet NEMA standards for Class F, in addition to the quality assurance requirements indicated above.. Maximum temperature rise shall not exceed 130 degrees C. Generator design shall prevent potentially damaging shaft currents. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... high conduction loss and switching loss. In fact,Q1 andQ2 can be controlled independently. As seen in Fig. 1, by neglecting the ripple of the inductor current iLf , the average inductor current ILf equals to Io /(1−d2 ), where Io is the output current, and d2 is duty cycle of Q2 . Therefore, reducin ...
... high conduction loss and switching loss. In fact,Q1 andQ2 can be controlled independently. As seen in Fig. 1, by neglecting the ripple of the inductor current iLf , the average inductor current ILf equals to Io /(1−d2 ), where Io is the output current, and d2 is duty cycle of Q2 . Therefore, reducin ...
MAX5974E Evaluation Kit Evaluates: MAX5974E General Description Features
... MagJackM. The EV kit features a 1 x 1Gb RJ45 MagJack and two full-bridge diodes for separating the DC power provided by an endspan or midspan Ethernet system. The EV kit circuit can also be powered by a +39V to +57V wall-adapter power source applied at the WAD_IN and WAD_GND PCB pads. When a wall-ad ...
... MagJackM. The EV kit features a 1 x 1Gb RJ45 MagJack and two full-bridge diodes for separating the DC power provided by an endspan or midspan Ethernet system. The EV kit circuit can also be powered by a +39V to +57V wall-adapter power source applied at the WAD_IN and WAD_GND PCB pads. When a wall-ad ...
SLO-SYN_SS2000MD4M
... 4.5.5 Potentiometers On board potentiometers are provided for setting the following motion parameters: Accel, Decel, Low Speed, and Run Speed. Run Speed can also be set via: a) external potentiometer, see Section 4.5.3. b) external voltage input 0-5V or 0-10V, see Section 4.5.4. This product is imp ...
... 4.5.5 Potentiometers On board potentiometers are provided for setting the following motion parameters: Accel, Decel, Low Speed, and Run Speed. Run Speed can also be set via: a) external potentiometer, see Section 4.5.3. b) external voltage input 0-5V or 0-10V, see Section 4.5.4. This product is imp ...
Communication Tests and Measurements
... dc and low-frequency ac applications. In RF applications, voltage measurements may be important under some conditions, but power measurements are far more common at higher frequencies, particularly microwave. In testing and troubleshooting communication equipment, you will still use a dc voltmeter t ...
... dc and low-frequency ac applications. In RF applications, voltage measurements may be important under some conditions, but power measurements are far more common at higher frequencies, particularly microwave. In testing and troubleshooting communication equipment, you will still use a dc voltmeter t ...
NG35 Datashhet
... The encoder (or optical line) must be connected with a shielded cable, to prevents electromagnetic interference . It's also recommended to have separated cable for each encoder and put far away the connection by interferences sources (inverters,high voltage cable, AC motors, etc.). NGIO is ready to ...
... The encoder (or optical line) must be connected with a shielded cable, to prevents electromagnetic interference . It's also recommended to have separated cable for each encoder and put far away the connection by interferences sources (inverters,high voltage cable, AC motors, etc.). NGIO is ready to ...
ServoOne Operation Manual Single-Axis System
... functional capability of the machine or plant concerned, and must be observed. The function of an emergency stop system does not necessarily cut the power supply to the drive. To protect against danger, it may be more beneficial to keep individual drives running or to initiate specific safety sequen ...
... functional capability of the machine or plant concerned, and must be observed. The function of an emergency stop system does not necessarily cut the power supply to the drive. To protect against danger, it may be more beneficial to keep individual drives running or to initiate specific safety sequen ...
12 02-13
... 1. Disconnect line heater 5 harness connector. Refer to Original Equipment Manufacturer (OEM) literature for schematic information. 2. Inspect the harness connector for signs of damaged, bent, spread, corroded or unseated (pushed out) pins and signs of moisture in the connector or wire damage near t ...
... 1. Disconnect line heater 5 harness connector. Refer to Original Equipment Manufacturer (OEM) literature for schematic information. 2. Inspect the harness connector for signs of damaged, bent, spread, corroded or unseated (pushed out) pins and signs of moisture in the connector or wire damage near t ...
Power Demand and Energy Usage of Container Crane
... To make a true comparison between AC and DC quay cranes, the electrical conditions have to be the same. It is assumed that the issue of poor power factor of DC drive quay crane has been solved (in the later section), comparison is now based on the peak kW demand rather than the peak kVA demand. As s ...
... To make a true comparison between AC and DC quay cranes, the electrical conditions have to be the same. It is assumed that the issue of poor power factor of DC drive quay crane has been solved (in the later section), comparison is now based on the peak kW demand rather than the peak kVA demand. As s ...
SubLVDS Camera Sensor Interface Reference Design (XAPP582)
... Figure 7: IBIS Simulation Model Using 50Ω VTT When probing using an IBIS model with Mentor Graphics, At DIE should be selected instead of At PIN. This gives a better simulation result. The differential output should be used to measure the eye opening. For this simulation, a differential probe was in ...
... Figure 7: IBIS Simulation Model Using 50Ω VTT When probing using an IBIS model with Mentor Graphics, At DIE should be selected instead of At PIN. This gives a better simulation result. The differential output should be used to measure the eye opening. For this simulation, a differential probe was in ...
Clamp-On AC Ammeter
... Hint: When you use the multimeter to probe for a voltage in a high-voltage circuit, we recommend you do not try to position both test leads at once. Instead, use an insulated alligator clip (not supplied) to clamp one test lead to the circuit's neutral or ground lead (usually a bare, green, or white ...
... Hint: When you use the multimeter to probe for a voltage in a high-voltage circuit, we recommend you do not try to position both test leads at once. Instead, use an insulated alligator clip (not supplied) to clamp one test lead to the circuit's neutral or ground lead (usually a bare, green, or white ...
A Study of Successive Approximation Registers and Implementation of an Ultra-
... When a digital code at the ADC output is not produced for the corresponding input voltage, there is a missing code. An example of missing code is illustrated in Figure 2.4. Whenever there is a missing code DNL is -1. ...
... When a digital code at the ADC output is not produced for the corresponding input voltage, there is a missing code. An example of missing code is illustrated in Figure 2.4. Whenever there is a missing code DNL is -1. ...
ADC14C105 14-Bit, 95/105 MSPS A/D Converter (Rev. C)
... Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is specified to be functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteri ...
... Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is specified to be functional, but do not ensure specific performance limits. For ensured specifications and test conditions, see the Electrical Characteri ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.