INSTRUCTION MANUALVIBRASWITCH MODEL Euro
... The Vibraswitch, Model EURO 366, is designed to protect rotating, reciprocating, or similar equipment against serious damage from malfunctions that can be detected as an increase in vibration. A reset and holding coil is provided, in the DC/AC voltage as specified so that accidental shutdowns on sta ...
... The Vibraswitch, Model EURO 366, is designed to protect rotating, reciprocating, or similar equipment against serious damage from malfunctions that can be detected as an increase in vibration. A reset and holding coil is provided, in the DC/AC voltage as specified so that accidental shutdowns on sta ...
evaluation of simple fault location on a mv feeder with dg
... US, IS: Feeder voltage and current measured in the substation during fault. UDG, IDG: Voltage and in-feed current in DG-node during fault. Index 0: Identifies pre-fault quantities, e.g. US,0 means pre-fault substation voltage. Each line section is 5 km. dE: distance from the substation to the feeder ...
... US, IS: Feeder voltage and current measured in the substation during fault. UDG, IDG: Voltage and in-feed current in DG-node during fault. Index 0: Identifies pre-fault quantities, e.g. US,0 means pre-fault substation voltage. Each line section is 5 km. dE: distance from the substation to the feeder ...
Handbook For Gel-VRLA-Batteries Part 2
... • A temperature related adjustment of the charge voltage within the operating temperature of 15° C to 35° C is not necessary. If the operating temperature is permanently outside this range, the charge voltage has to be adjusted as shown in figures 3, 4 and 5. Gel-solar batteries: See also chapter 6. ...
... • A temperature related adjustment of the charge voltage within the operating temperature of 15° C to 35° C is not necessary. If the operating temperature is permanently outside this range, the charge voltage has to be adjusted as shown in figures 3, 4 and 5. Gel-solar batteries: See also chapter 6. ...
HC900 Process Controller Modules Specifications
... status LED when module diagnostics exist. A userselectable failsafe value is supported on a per channel basis. A warning signal is provided for thermocouple inputs to indicate maintenance is needed prior to a sensor failure. A sensor failure signal is also provided. ...
... status LED when module diagnostics exist. A userselectable failsafe value is supported on a per channel basis. A warning signal is provided for thermocouple inputs to indicate maintenance is needed prior to a sensor failure. A sensor failure signal is also provided. ...
branch equations
... instructions for each branch and node, or in the case of a load flow calculation, for each bus and transmission line. An input program is available for this purpose. If the connection diagram is large, calculation results may be hard or impossible to read on the graphical output after the necessary ...
... instructions for each branch and node, or in the case of a load flow calculation, for each bus and transmission line. An input program is available for this purpose. If the connection diagram is large, calculation results may be hard or impossible to read on the graphical output after the necessary ...
Safety_Requirements
... formulate a set of design outputs for a given product. • Design Inputs must include customer (user) level requirements as well as product level and flow down to block level requirements • Design Outputs • All drawings, documents, procedures, instructions and other information necessary to describe t ...
... formulate a set of design outputs for a given product. • Design Inputs must include customer (user) level requirements as well as product level and flow down to block level requirements • Design Outputs • All drawings, documents, procedures, instructions and other information necessary to describe t ...
MAX9025–MAX9028 UCSP, 1.8V, Nanopower, Beyond-the-Rails Comparators With/Without Reference General Description
... current. These features make the MAX9025–MAX9028 family of comparators ideal for all 2-cell batterymonitoring/management applications. The unique design of the output stage limits supplycurrent surges while switching, virtually eliminating the supply glitches typical of many other comparators. This ...
... current. These features make the MAX9025–MAX9028 family of comparators ideal for all 2-cell batterymonitoring/management applications. The unique design of the output stage limits supplycurrent surges while switching, virtually eliminating the supply glitches typical of many other comparators. This ...
DeSantis_LBNL - CLASSE Wiki
... • Shorter modules, if power figures allow, are beneficial, yet more expensive. • The effects of modules in different locations on the ring need to be investigated, as well as ...
... • Shorter modules, if power figures allow, are beneficial, yet more expensive. • The effects of modules in different locations on the ring need to be investigated, as well as ...
EOLS-1503-C-D
... 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR a ...
... 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR a ...
Hazardous conditions may result of the charger is not installed or
... Connecting the batteries or other DC loads The output has a common Negative ( - ) terminal and 3 Positive terminals for connection of 3 banks of batteries. Each Positive connector has it’s own internal isolating diode which works as a battery isolator. If more than one bank of batteries is connected ...
... Connecting the batteries or other DC loads The output has a common Negative ( - ) terminal and 3 Positive terminals for connection of 3 banks of batteries. Each Positive connector has it’s own internal isolating diode which works as a battery isolator. If more than one bank of batteries is connected ...
Colossus Amplifiers
... The key to finding the problem in a misbehaving sound system is to isolate parts of that system in a logical fashion to track down the fault. Description of the Diagnostic system built into all HIFONICS amplifiers The diagnostic system will shut down the amplifier, until reset by turning the head un ...
... The key to finding the problem in a misbehaving sound system is to isolate parts of that system in a logical fashion to track down the fault. Description of the Diagnostic system built into all HIFONICS amplifiers The diagnostic system will shut down the amplifier, until reset by turning the head un ...
harmonic analysis model
... the ACRAWin32 data viewer, or commercially available spreadsheet software. Screen data from your OR100E/ OR300E recorder can be saved in bitmap (BMP) format as graphical objects. Saved bitmap files can be pasted into documents in Windows programs such as word processors to easily create reports. Mor ...
... the ACRAWin32 data viewer, or commercially available spreadsheet software. Screen data from your OR100E/ OR300E recorder can be saved in bitmap (BMP) format as graphical objects. Saved bitmap files can be pasted into documents in Windows programs such as word processors to easily create reports. Mor ...
04_DC AC Meter - UniMAP Portal
... attraction is very small for common voltages. It is so small that such meter movement designs are impractical for use in general test instruments. Typically, electrostatic meter movements are used for ...
... attraction is very small for common voltages. It is so small that such meter movement designs are impractical for use in general test instruments. Typically, electrostatic meter movements are used for ...
ZXTP4003G - Diodes Incorporated
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Shaft Generator Systems
... electronics. The losses of diodes are less than those of thyristor rectifiers which are used on similar systems. The rectifier is mounted on top of the shaft generator in space saving manner, thus providing a compact shaft generator panel. ...
... electronics. The losses of diodes are less than those of thyristor rectifiers which are used on similar systems. The rectifier is mounted on top of the shaft generator in space saving manner, thus providing a compact shaft generator panel. ...
REPL ACEMENT PROGAM
... controls. We can provide pricing information immediately and most controls are available from stock. Refer to the Quick Reference Guide to find a Beckwith Electric direct replacement control. The guide is organized into two sections: transformer controls and regulator controls. Controls are listed a ...
... controls. We can provide pricing information immediately and most controls are available from stock. Refer to the Quick Reference Guide to find a Beckwith Electric direct replacement control. The guide is organized into two sections: transformer controls and regulator controls. Controls are listed a ...
$doc.title
... The bandwidth of the IF amplifier is about 40MHz, with 44dB(v) of gain from a 50Ω source. The bandwidth of the limiter is about 28MHz with about 58dB(v) of gain from a 50Ω source. However, the gain/bandwidth distribution is optimized for 9.8MHz, 330Ω source applications. The overall system is well-s ...
... The bandwidth of the IF amplifier is about 40MHz, with 44dB(v) of gain from a 50Ω source. The bandwidth of the limiter is about 28MHz with about 58dB(v) of gain from a 50Ω source. However, the gain/bandwidth distribution is optimized for 9.8MHz, 330Ω source applications. The overall system is well-s ...
Industrial Product Catalog
... mechanical load using the built in advanced control algorithms and features of Elmo’s powerful perfectly tuned servo drives. ...
... mechanical load using the built in advanced control algorithms and features of Elmo’s powerful perfectly tuned servo drives. ...
Mains electricity
Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.