• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NX Series Analog Output Units Datasheet
NX Series Analog Output Units Datasheet

... Free-run refreshing or synchronous I/O refreshing can be selected using the NX-series EtherCAT Coupler. Output update cycles of 10 μs per channel, and resolution of 1/30000, ideal for high-speed, high-precision control. The screwless terminal block is detachable for easy commissioning and maintenanc ...
ISK 110 VESA
ISK 110 VESA

... motherboard manual for specific mounting instructions and troubleshooting. Before proceeding, check the manual for your CPU cooler to find out if there are steps you must take before installing the motherboard. While installing hardware, keep your case on a flat, stable surface. ...
ZXT2MA Features and Benefits Mechanical Data
ZXT2MA Features and Benefits Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Galvanic and electrolytic corrosion
Galvanic and electrolytic corrosion

... faults, such as lack of anodes or faulty wiring, become yours. Your anodes could end up protecting your neighbour’s huge cathodic bronze fittings, or even the marina’s steel pilings which you may now be connected to. If the boats both have metal hulls, these too can function as a giant anode and cat ...
The Spider robot controllers were designed for robots requiring a
The Spider robot controllers were designed for robots requiring a

AN 574: Printed Circuit Board (PCB) Power Delivery Network
AN 574: Printed Circuit Board (PCB) Power Delivery Network

... Figure 7 shows the schematic and equivalent representation of spreading and ball grid array (BGA) via inductance. In addition to mounting inductance associated with placing a capacitor on the PCB, the effectiveness of a decoupling capacitor also depends on the spreading inductance that the capacitor ...
AN139 - Power Supply Layout and EMI
AN139 - Power Supply Layout and EMI

... of his AM band in a car radio receiver. No additional metal shielding was required for the power supply unit (PSU); it was only an issue of placement and layout. In order to get there, we need to go through some physics. With nonisolated topologies, one of the most basic topologies is the buck regul ...
Reference Design # 0618 IRAC1166-100W
Reference Design # 0618 IRAC1166-100W

Noise - ISY@LiU
Noise - ISY@LiU

... saturation region is approximated by a current source tied between the source and drain terminals, or can be modeled by a voltage source in series with gate. ...
BSX - Thermon
BSX - Thermon

... Form TEP0067U-0113 • © Thermon Manufacturing Co. • Printed in U.S.A. • Information subject to change. ...
S280-70-8
S280-70-8

... block TB8. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calculations. Data sampling occurs at a rate of 64 times per cycle. The CPU contains a data acquisition section that uses the acquired samples to compute th ...
ADP-40 Analog Door Phone P/N 1200761L1
ADP-40 Analog Door Phone P/N 1200761L1

... electrical box must be mounted flush and must not extend beyond the front surface of the siding. Make sure the mounting location is free of wall studs, wires, etc. Place the electrical box level against the siding. Trace the outline of the box on the siding. Cut a hole through the siding and wall sh ...
Electronically Scanned Composite Right/Left Handed Microstrip
Electronically Scanned Composite Right/Left Handed Microstrip

... and is the period of the structure. Equation (1) shows that the radiation angle is determined by the guided wavelength or by the period . Horn et al. [8] electronically changed by modulating p–i–n diodes in a dielectric waveguide antenna, but the resulting antenna allows only two discrete radiation ...
M48T35AV
M48T35AV

... clock control circuit which updates the clock bytes with current information once per second. The information can be accessed by the user in the same manner as any other location in the static memory array. The M48T35AV also has its own Power-fail Detect circuit. The control circuitry constantly mon ...
GE WTG Modeling-v4 2..
GE WTG Modeling-v4 2..

... equipped with a solid-state voltage-source converter AC excitation system. The AC excitation is supplied through an ac-dc-ac converter. For the GE 3.6 MW machine the converter will be connected as shown or to a third winding on the main unit step-up transformer. For the GE 1.5 MW machine it is conne ...
μ  PD166020T1F Data Sheet
μ PD166020T1F Data Sheet

... connected to GND via an external resister. Next, the voltage at the source of SW1 (= gate of output MOS) falls below the GND voltage. SW1 is turned on, and the clamp diode is connected to the gate of the output MOS, activating the dynamic clamp circuit. When the over-voltage is applied to VCC, the g ...
DATA SHEET Tytan II D0-25-1/S
DATA SHEET Tytan II D0-25-1/S

... Fuse switch-disconnectors combine fuse protection of system parts with switching capability under load as well as when in overload. Tytan II series devices are main fuse switch-disconnectors for D01 and D02 fuses. Simultaneous isolation of all phases is ensured by the screwcap-less plug-in technolog ...
AC Induction Motor Stator Resistance Estimation Algorithm
AC Induction Motor Stator Resistance Estimation Algorithm

... magnet which was connected to Statron electronic load with adjustable current. The voltage and current waves were saved in files using FreeMaster software in real time and than they were treated in the environment of Matlab. The RMS values were computed and the active power as well. These values wer ...
ELECTROTECHNOLOGY N3
ELECTROTECHNOLOGY N3

... The operation of direct current motors and generators is not only the same in principle, but the practical design does not differ much either. A direct current motor can be used as a generator and vice versa. However, if we consider the purpose of each machine and where it is used, there are a few d ...
investigation of electron and hole tunneling through thin silicon
investigation of electron and hole tunneling through thin silicon

Technical Information Temperature Switch Thermophant T TTR31
Technical Information Temperature Switch Thermophant T TTR31

... – one PNP switch output – two PNP switch outputs – 2 x PNP switch outputs or one PNP switch output and 4 to 20 mA output (active) Benefits at a glance This compact temperature switch impresses with the latest in technology being used: • Integrated switching electronics for decentral and economic pro ...
Topic 4: Digital Circuits
Topic 4: Digital Circuits

Analysis of energy-saving structures of electric machines for
Analysis of energy-saving structures of electric machines for

... the prototype alone was higher by about 25.3%. The stator stack of the prototype switched reluctance motor was 25% shorter than the stack of the commutator motor at the same outer diameter of the rotor. Nevertheless, a 20% increase in the output power was achieved at the same value of input power. I ...
Basic Precipitator Troubleshooting
Basic Precipitator Troubleshooting

... Basic Precipitator Troubleshooting Comparing like areas of the precipitator can reveal problems that are not obvious from a glance of the electrical readings ...
S280-70-15
S280-70-15

... • NOVA-TS: via a junction box and control cable • NOVA STS: via control cable This wiring also supplies Trip, Close, and Recloser status, and connects to the Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog input module. L ...
< 1 ... 267 268 269 270 271 272 273 274 275 ... 1974 >

Mains electricity



Mains electricity is the general-purpose alternating-current (AC) electric power supply. In the US, electric power is referred to by several names including household power, household electricity, house current, powerline, domestic power, wall power, line power, AC power, city power, street power, and grid power.The two principal properties of the electric power supply, voltage and frequency, differ between regions. A voltage of (nominally) 230 V and a frequency of 50 Hz is used in Europe, most of Asia, most of South America and Australia. In North America, the most common combination is 120 V and a frequency of 60 Hz. Other voltages exist, and some countries may have, for example, 230 V but 60 Hz. This is a concern to travelers, since portable appliances designed for one voltage and frequency combination may not operate or may be destroyed by another.The use of different plugs and sockets in different regions provides some protection from accidental use of appliances with incompatible voltage and frequency requirements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report