• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
String Combiners in SolarEdge Systems, North America
String Combiners in SolarEdge Systems, North America

... The intent is to provide overcurrent protection for circuits connected to more than one electrical source. All sources of current need to be considered: multiple series strings of PV modules connected in parallel to the inverter as well as the string inverter itself. SolarEdge inverters have been ve ...
ii In the recent days, the increased emphasis is being given on the
ii In the recent days, the increased emphasis is being given on the

Series - RAM Audio
Series - RAM Audio

... it compares the above mentioned parameters, then changes the input signal amplitude to fit the signal between the supply levels, thus avoiding clipping. This change is made on the basis of two time constants, attack and release, this permits no dynamics loss in the first cycles and avoids the "pumpi ...
File u208b | allcomponents.ru
File u208b | allcomponents.ru

... the pulse width can be evaluated by assuming 8 ms/nF). The current sensor on Pin 8 ensures that, for operation with inductive loads, no pulse will be generated in a new half cycle as long as the current from the previous half cycle is still flowing in the opposite direction to the supply voltage at ...
DSL  Primary Switched Battery Charging and Power Supply Unit GL4024
DSL Primary Switched Battery Charging and Power Supply Unit GL4024

... The GL4024 charging unit is set to a battery voltage of 26.6V in no-load operation before leaving the factory. The final charging voltage is adjusted in no-load operation using the adjuster on the bottom of the unit (it is best to do this before mounting and wiring to the top-hat rail). In mounting ...
Ground Power Supply The external AC ground supply receptacle is
Ground Power Supply The external AC ground supply receptacle is

Proposal to - Power Correction Systems Inc.
Proposal to - Power Correction Systems Inc.

... Harmonic currents have been present in the electricity supply system for many years. Initially the mercury arc rectifiers used to convert AC to DC for DC variable speed drives in industry produced them. More recently the range of types and number of units of equipment causing harmonics have risen sh ...
datasheet - PFIFFNER Instrument Transformers Ltd
datasheet - PFIFFNER Instrument Transformers Ltd

... The SF6 gas density is monitored by a temperature-compensated gas density monitor with alarm contacts. The special design means the function of the gas density monitor can be ...
EMS+Lecture+16
EMS+Lecture+16

... EO = Zn/60  The voltage drop across the armature resistance is always small compared to the supply voltage  Even as the load varies from no-load to fullload  EO is approximately equal to ES EO = Zn/60 n = 60EO /Z ≈ 60ES /Z ...
Muddiest Points Wk 1
Muddiest Points Wk 1

... They have only one ordinary node between them. (They share only one color, and it is on an ordinary node.) Current is equal in series elements. Voltage is generally NOT equal across series elements. (It is equal across two resistors only if the resistors are equal.) When tracing a path through one e ...
university of north carolina at charlotte
university of north carolina at charlotte

... Table 1. Summary of MOSFET Amplifier Characteristics Based upon the current technology in use, most MOSFET amplifiers are fabricated on integrated circuits. This fabrication process, with such small feature processing, makes it very difficult to create resistors on an integrated circuit. When fabric ...
Linear Systems replaces discontinued Intersil IT120
Linear Systems replaces discontinued Intersil IT120

FPGA Based Speed Control of Three
FPGA Based Speed Control of Three

... system is shown in Fig.3. This system uses three saw-tooth generators each of them is synchronized with one of the supply voltages. The synchronization is achieved by detecting the zero crossing point of phase a voltage (only negative to positive transitions are detected). Another module of this sys ...
September 2009 - 3mm × 3mm, 16-Bit ADC Brings Accurate, Precise High Side Current Sensing to Tight Spaces
September 2009 - 3mm × 3mm, 16-Bit ADC Brings Accurate, Precise High Side Current Sensing to Tight Spaces

... Power monitoring circuits are increasingly used throughout automotive, industrial, communications and computing applications as electronics designers strive to continually improve thermal performance, increase efficiency and generally make their products more “green.” The problem is that power monit ...
52911
52911

... (+48VDC) via front panel connections. This approach not only minimizes power ...
Secondary Wiring Methods
Secondary Wiring Methods

... 4) Conversion to Virtual Mid-Point Wiring from Mid Point Ground Wiring When retrofitting a sign that uses the mid-point ground wiring method, with a secondary ground fault protected transformer, follow the procedure depicted in the diagram to convert the wiring to virtual midpoint ground. The return ...
Power Factor Improvement Experiment # 4 Power Factor
Power Factor Improvement Experiment # 4 Power Factor

tayyab here
tayyab here

... which in turn causes losses in the transmission and distribution system. Due to increase in losses in distribution system, the line voltage at remote areas will decreases. Due to advancements in power electronic converters to maintain the load voltage as constant equipment like DVR, D-STATCOM are us ...
STK402-040
STK402-040

... semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety meas ...
VCC power off, brownout, and power on
VCC power off, brownout, and power on

... (see data sheet for specific timing) after the VCC voltage reaches the minimum operating VCC level. While the device is being powered-on, the internal Power-On Reset (POR) circuitry keeps the device in a reset mode until the supply voltage rises above the POR maximum threshold (VPOR MAX). During thi ...
Polyphase Systems
Polyphase Systems

... that in order to have a balanced load, the phase angle must also be the same for each impedance—a condition that was unnecessary in dc circuits when we considered balanced systems. In practice, if a factory, for example, had only balanced, three-phase loads, the absence of the neutral would have no ...
Industrial Power System Design in a Utility Environment
Industrial Power System Design in a Utility Environment

... base length between poles for a specific The load is geographically conconductor size. For utilities and coops, this is in the 90-m (295-ft) range for conductors 1/0 tained within multiple electric utility service areas. ACSR and smaller, and 76 m (250 ft) for 4/0 and 477 Pricing of electric service ...
PowerPoint 프레젠테이션
PowerPoint 프레젠테이션

... External AC/DC Adaptor ...
higher harmonics analize in led diode lamps used to illumination
higher harmonics analize in led diode lamps used to illumination

April 30, 2008
April 30, 2008

... check and adjust (an iterative process) all 12 cases. It takes about 1 week to fix the bus voltages to within 2.5 kV for one operational case for about 100 buses. If the same care was applied to the loss factor cases, the ISO would have to adjust about 600-700 buses for each of the 12 cases and we e ...
< 1 ... 883 884 885 886 887 888 889 890 891 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.