• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN-1332 APPLICATION NOTE
AN-1332 APPLICATION NOTE

... Figure 1 shows how a direct, 3-phase energy meter is connected in a 3-phase, 4-wire system. The Phase A line connects to Terminal 1 and Terminal 3 of the meter, Phase B connects to Terminal 4 and Terminal 7, Phase C connects to Terminal 7 and Terminal 9, and the neutral line connects to Terminal 10 ...
Presentation: Error Control Coding
Presentation: Error Control Coding

... Energy dissipation over a period: ...
ELTC 101 - Muskegon Community College
ELTC 101 - Muskegon Community College

IMEC, Leuven, Belgium, K.U.Leuven, Leuven, Belgium
IMEC, Leuven, Belgium, K.U.Leuven, Leuven, Belgium

... Figure 6. Voltage generated as a function of displacement over a 1 MΩ load resistor. In this way the mass moves across multiple capacitances per cycle. The shape of the signal corresponds to the simulated and measured changes of capacitance versus displacement. During this test the polarisation volt ...
LED570-06
LED570-06

... During operation these LEDs do emit light, which could be hazardous to skin and eyes, and may cause cancer. Do avoid exposure to the emitted light. Protective glasses if needed. It is further advised to attach a warning label on products/systems. ...
dynamic model of pm synchronous motors
dynamic model of pm synchronous motors

... flux densities [8]. Since inductance is also subject to saturation, we need to measure inductances at various current level of interest. Furthermore, when motor windings are delta-connected or Y connected without neutral line for external access, one can only access line-to-line value. Even when pha ...
High Reliability
High Reliability

... are defined as single event upset (SEU), single event transient (SET) and single event functional interrupt (SEFI) errors. Destructive or “hard-error effects” interrupt device function and can permanently damage the device without prompt external mitigation. These types of errors are defined as sing ...
J31066073
J31066073

... power control over a wide range of power for different cooking purposes where a ZVS condition must be met to ensure high efficiency . By using the mentioned techniques in fixed frequency and the optimum duty cycle for ZVS operation, it is rather difficult to control the output power due to variation ...
Chapter 3
Chapter 3

... These devices are generally quite simple in operation. If current is supplied to a wire coiled about a bar of iron a magnetic field will be generated around this device. We made a crude electromagnet using a bolt and enamelled copper wire. This wire has a flexible coating of insulation around it and ...
DMMS 300+ - Electro Industries
DMMS 300+ - Electro Industries

PT-6008-GeneratorReactances-en
PT-6008-GeneratorReactances-en

... Design Engineer, Technical Project Leader and Project Manager. His current position is a Technical SpecialistElectrical in application engineering for Cummins ...
Power Factor
Power Factor

...  The average power in a circuit is called active power and the power that supplies stored energy to reactive elements is called reactive power.  P.F For Inductive load: Inductive loads cause the current to lag behind the voltage.The wave form of voltage and curret then are “out of phase” with eac ...
Aalborg Universitet and Harmonics in Microgrids
Aalborg Universitet and Harmonics in Microgrids

Advanced Dissectable and Configurable Electrical Machines AEL-EMT-KIT Technical Teaching Equipment
Advanced Dissectable and Configurable Electrical Machines AEL-EMT-KIT Technical Teaching Equipment

... As a motor: to work as a motor, the user can control field and excitation currents depending on the configuration (independent, series, shunt and compound). Thus, apart from assembling the machine, both the velocity and torque of the machine can be controlled. It includes: • Rotor. This element cons ...
Current Mirrors - Marshall Leach
Current Mirrors - Marshall Leach

... through r03 , causing the emitter voltage of Q3 and the base voltage of Q1 to increase. The increase in voltage at the emitter of Q3 causes its collector voltage to increase because Q3 is a common-base stage for an emitter input. Because Q1 is a common-emitter stage for a base input, the increase ...
More Circuit Components: Capacitors, Inductors, and Diodes
More Circuit Components: Capacitors, Inductors, and Diodes

... Transformer ...
SP232A
SP232A

SP232A Enhanced RS-232 Line Drivers/Receivers FEATURES
SP232A Enhanced RS-232 Line Drivers/Receivers FEATURES

... ceramic capacitors are ideal for use on charge pump. If polarized capacitors are used the positive and negative terminals should be connected as shown on the typical operating circuit. A diagram of the 4 individual phases is shown in Figure 1. ...
j500 j501 j502 j503 j504 j505 j506 j507 j508 j509 j510 j511 current
j500 j501 j502 j503 j504 j505 j506 j507 j508 j509 j510 j511 current

... Note: All MIN/TYP/MAX limits are absolute numbers. Negative signs indicate electrical polarity only. ...
APE8862 - Advanced Power Electronics Corp.
APE8862 - Advanced Power Electronics Corp.

136. multilevel inverters for high power applications with improved
136. multilevel inverters for high power applications with improved

... A simple 3-phase, 3-level cascaded inverter topology is discussed here. It consists of 36 switching devices and 9 dc sources. During switching of these switches there will be a high switching loss which may reduce the overall efficiency of the system as well as introduce harmonics into the supply sy ...
Programmable Single-/Dual-/Triple
Programmable Single-/Dual-/Triple

... generator produces the DAC reference current IL for all three tones. This requires connecting an external resistor to ground. The chip temperature is monitored by the junction control. At temperatures of more then approx. 170 ˚C the stop input will switch the output current II to zero. The output cu ...
redefined
redefined

... 1. Set the measuring dial of your meter to VDC. Choose a maximum measuring range of +20VDC or higher. 2. To measure the +12V1 output: Use a 4-pin Molex connector from the power supply and insert the positive pole (red) to the connector pin with the yellow wire. Insert the negative (black) to one of ...
Technique for Accurate Voltage Measurement of Energized Street
Technique for Accurate Voltage Measurement of Energized Street

... voltage because voltage from a phase conductor has a different waveform than neutral return. IEEE Standard 519 recommends no more than 5% voltage THD on a distribution line and no more than 3% of any individual harmonic e.g 3rd harmonic. Utilities are normally required to operate below the recommend ...
Parameters of OP-AMP
Parameters of OP-AMP

... Typical value for 741 IC is 2 mega ohm. ...
< 1 ... 652 653 654 655 656 657 658 659 660 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.