• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Converting Biomechanical Energy into Electricity
Converting Biomechanical Energy into Electricity

... was dramatically decreased, as shown in Figure 3d. Some large signals were also observed in Figure 3d, which might be due to the nonperiodic body movement of the hamster and the nonperfect synchronization of the two SWGs. However, the apparent enhancement with in-phase connection and decrease with o ...
TPS2375-77 - Texas Instruments
TPS2375-77 - Texas Instruments

... from ILIM to VSS, in ohms. The practical limits on R(ILIM) are 62.5 kΩ to 500 kΩ. A value of 178 kΩ is recommended for compatibility with legacy PSEs. Inrush current limiting prevents current drawn by the bulk capacitor from causing the line voltage to sag below the lower UVLO threshold. Adjustable ...
MAX6775–MAX6781 Low-Power, 1%-Accurate Battery Monitors in µDFN and SC70 Packages General Description
MAX6775–MAX6781 Low-Power, 1%-Accurate Battery Monitors in µDFN and SC70 Packages General Description

... The MAX6775–MAX6781 low-power, 1%-accurate battery monitors are available in the ultra-small µDFN package (1.0mm x 1.5mm) and SC70 packages. These low-power devices are ideal for monitoring single lithium-ion (Li+) cells, or multicell alkaline/NiCd/NiMH power sources. These devices offer single (MAX ...
Microgrid Stability Controller Based on Adaptive Robust Total
Microgrid Stability Controller Based on Adaptive Robust Total

... This paper proposes a “microgrid stability controller” (MSC) based on energy storage equipment, which provides for islanding operation functionality to conventional DG systems without changing their gridconnected control strategies. In addition, in grid-connected mode, the MSC can smooth the exchang ...
a Low Noise, Precision Instrumentation Amplifier AMP01*
a Low Noise, Precision Instrumentation Amplifier AMP01*

... voltage swing is guaranteed with three load resistances; 50 Ω, 500 Ω, and 2 kΩ. Loaded with 500 Ω, the output delivers ± 13.0 V minimum. A thermal shutdown circuit prevents destruction of the output transistors during overload conditions. The AMP01 can also be configured as a high performance operat ...
A balancing and monitoring system for battery cell stacks in
A balancing and monitoring system for battery cell stacks in

... Electrical vehicles and hybrid electrical vehicles, HEV, have begun to take a large space in the automotive type of business. Electrical motors are far more energy efficient than conventional combustion engines running on petrol or diesel. The high price on oil as well as the awareness of environmen ...
ZXBM5210 Description Pin Assignments
ZXBM5210 Description Pin Assignments

... motor mechanical and coil design parameters and not limited by the output capability of the device. If voltage at VDD is lower than the nominal motor voltage, both start-up PWM duty and minimum running PWM duty required will be higher. ...
Rockwell Automation Allen-Bradley Specification SMC
Rockwell Automation Allen-Bradley Specification SMC

... 1. Soft stop a.) The soft stop option shall provide a voltage ramp-down for an extended motor stopping time. b.) Soft stop shall be initiated by a dedicated Soft Stop input. A coast-to-rest stop shall still be possible with a separate stop input. c.) Programmable voltage ramp down time from 100 to 3 ...
Cisco IE 3000 65 W DC-Input Power Supply Installation Note
Cisco IE 3000 65 W DC-Input Power Supply Installation Note

... The DC-input power supply can support up to a maximum of four PoE ports or two PoE+ ports. If you intend to operate all four PoE ports on the expansion module in PoE+ mode, you can not use the power supply; you must use site source DC power. ...
RSU002P03
RSU002P03

... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
17 - Northern Highlands
17 - Northern Highlands

... Coiling wires When a wire is made into a coil, the total magnetic field is the sum of the ...
ASCO Model 510 Guide Specifications (word version)
ASCO Model 510 Guide Specifications (word version)

... exception statements to all provisions of this specification to allow consideration. Additionally, manufacturers shall submit test data verifying the following: life cycle testing, overcurrent protection, ANSI/UL 1449 Fourth Edition, noise attenuation and surge current capacity. Failure to do so wil ...
Guide to Commercial Installations Distribution Boards
Guide to Commercial Installations Distribution Boards

... to be selected to have a minimum fault current rating of 5kA, assuming that the line to neutral prospective fault current is equal to or higher than the prospective earth fault current. 434.5.1 states that the short circuit capacity of devices in the distribution board shall not be less than the pro ...
RBE-12/20-D48 Series
RBE-12/20-D48 Series

NA Y.3 Connections to mains
NA Y.3 Connections to mains

... A d.c. power distribution system (d.c. mains) is a power distribution system with or without batteries, external to the equipment, for supplying power to d.c. powered equipment. Note A d.c. power distribution system with storage batteries, often called a centralized d.c. power system, consists of op ...
AD8571,72,74 - Analog Devices
AD8571,72,74 - Analog Devices

AC Machines - UniMAP Portal
AC Machines - UniMAP Portal

... This equation shows the magnitude of the voltage induced in a given stator phase. ...
FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... requires approximately 400µs to achieve specified VOS accuracy, which includes one full auto-zero cycle of approximately 100µs and the start-up time for the bias circuitry. Prior to this time, the amplifier will function properly but with unspecified offset voltage. This design has virtually no alia ...
TG61B - CE Niehoff Co.
TG61B - CE Niehoff Co.

... load on accessory drive system. The soft start may take up to 10 seconds at full electrical load. ...
Characteristic Curves
Characteristic Curves

... Typical multiple-transistor packages. ...
Installation and Operation Guide PD4600 Series Converter
Installation and Operation Guide PD4600 Series Converter

... 7. Attach new adapter bracket to power center using (2) screws removed in step #6. 8. Remove new converter core assembly from provided enclosure, by removing (4) screws securing converter to enclosure and slide converter out. Discard the metal enclosure and screws as they are not used when replacing ...
Viesturs Bražis. Asynchronous electric drive with frontal part winding
Viesturs Bražis. Asynchronous electric drive with frontal part winding

... s= l. At stationary regime, when transformer does not realize the control, it has been described as choke with ignoring the transformer secondary circuit parameters. In the computations of induction motor with frontal part winding it is not useful to utilize the Г type substitution scheme, because t ...
Application Note: 1 LED Power Supplies Common LED Configurations
Application Note: 1 LED Power Supplies Common LED Configurations

... There are no current imbalance issues as all LEDs receive identical current. System efficiencies tend to be high as it is easier to optimize efficiency with high voltage and low current. No ballast resistors are required which tend to reduce efficiency. The most common LED failure mode has negligibl ...
LT Journal of Analog Innovation V26N2
LT Journal of Analog Innovation V26N2

... controller to drive LED loads at continuous currents exceeding 20A. The supply input for the LT3744 is designed to handle 3.3V to 36V. As a step-down converter, it regulates LED current from 0V up to the supply voltage. As an inverting buck-boost converter, the LT3744 can accurately regulate LED cur ...
G. Hassan, D.J. Perreault, and T.A. Keim, “Design of Dual-Output Alternators with Switched-Mode Rectification,” 2003 IEEE Power Electronics Specialists Conference , Acapulco, Mexico, June 2003, pp. 1992-2000.
G. Hassan, D.J. Perreault, and T.A. Keim, “Design of Dual-Output Alternators with Switched-Mode Rectification,” 2003 IEEE Power Electronics Specialists Conference , Acapulco, Mexico, June 2003, pp. 1992-2000.

... Here we describe the prototype system that was developed to validate the proposed approach. A. Experimental Alternator and Drive Stand The setup for the experiment is based on a standard Lundell automotive alternator (14 V, 65/130 A) that is driven by a computer controlled variable-speed drive (13.4 ...
< 1 ... 266 267 268 269 270 271 272 273 274 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report