• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Simulating FPGA Power Integrity Using S-Parameter Models
Simulating FPGA Power Integrity Using S-Parameter Models

... spreading inductance associated with the package or PCB combines with the decap's intrinsic inductance to effectively model the loop inductance. This loop inductance plus the package inductance resonates with the die capacitance to form a parallel anti-resonant circuit with a unique impedance profil ...
AAT3603A 数据资料DataSheet下载
AAT3603A 数据资料DataSheet下载

... current, charge termination current, and recharge voltage are programmable with an external resistor and/or by a standard I2C interface. The step-down DC/DC converter is integrated with internal compensation and operates at a switching frequency of 1.5MHz, thus minimizing the size of external compon ...
High Frequency Modeling for Cable and Induction Motor Over
High Frequency Modeling for Cable and Induction Motor Over

... evaluate the overvoltage phenomenon accurately for different cable lengths and for different voltage pulse rise times. In the program, one chooses the number of lumped sections as well as the simulation time step. The whole system can be simulated in a two-axes ( – ) approach, which reduces the numb ...
Auto-Electric Basic Technology - Part 2
Auto-Electric Basic Technology - Part 2

... Between the terminal numbers “85” and “86” there is placed the electromagnet (winding & soft iron core). This part of the relay we may name as steering circuit. That means, if we connect one of these terminals to the ground and the other one to the positive a current flow through the winding and bui ...
Evaluates:  MAX1583 MAX1583 Evaluation Kit General Description Features
Evaluates: MAX1583 MAX1583 Evaluation Kit General Description Features

... EN1 and EN2 on the MAX1583 provide control for shutdown mode, movie mode, precharge mode, and strobe mode. Jumpers JU1 and JU2 connect EN2 and EN1 to either VIN or GND (see Table 1). An external signal can be used to drive EN1 or EN2 by removing the corresponding shunt completely from the jumper and ...
P84453
P84453

... If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer’s install ...
Reinaldo
Reinaldo

... solution once they are a matched solution for a specific operation point (wind speed and output power). The losses study also has demonstrated that the PMSG efficiency (η) remains practically constant and the system η is the lowest when the HTF are used. ...
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2196-2203
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2196-2203

... are considered from 20ms corresponding to source phase angle 0o to 40ms corresponding to source phase angle 360o in steps of 1.667ms or 30o. The obtained voltage waveforms at the receiving end for each step are shown in figures 5-7. Table 2 summarizes the peak values (+ve) and (-ve) for the three ph ...
Asian Power Electronics Journal
Asian Power Electronics Journal

... The principal function of the inverters is to generate an AC voltage from a DC source voltage. If the DC voltage sources connected in series, it becomes possible to generate an output voltage with several steps. Multilevel inverters include an arrangement of semiconductors and DC voltage sources req ...
RD-3x Dytronic Energy Reference Standard
RD-3x Dytronic Energy Reference Standard

... The RD-3x incorporates Radian’s patented Dytronic measurement technology consisting of a Radian designed Integrating Analog to Digital Signal Converter. Unlike off-the-shelf A/D converters used in similar instruments, Radian’s A/D Converter is specifically designed and optimized for power and energy ...
XAPP459 - Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins on Spartan-3 Families
XAPP459 - Eliminating I/O Coupling Effects when Interfacing Large-Swing Single-Ended Signals to User I/O Pins on Spartan-3 Families

... these families to handle many different single-ended signal standards. The standard singleended signaling voltage levels are 1.2V, 1.5V, 1.8V, 2.5V, and 3.3V. There are a number of applications for which it is desirable to receive signals with a greater voltage swing than User I/O pins ordinarily pe ...
Drive and Motor Basics - Allen
Drive and Motor Basics - Allen

... distributed around the stator periphery, Pull-up Torque is greatly reduced. Some motor design curves show no actual Pull-up Torque and follow the dashed line between points A and C. As acceleration continues, rotor frequency and inductive reactance decrease. The rotor flux moves more in phase with t ...
Zero Sequence Current Compensation for Distance
Zero Sequence Current Compensation for Distance

BD8967FVM
BD8967FVM

... 5. Consideration on Permissible Dissipation and Heat Generation Since this IC functions with high efficiency without significant heat generation in most applications, no special consideration is needed on permissible dissipation or heat generation. In case of extreme conditions, however, including l ...
High-Efficiency Ripple-Free Power Converter for Nuclear
High-Efficiency Ripple-Free Power Converter for Nuclear

TPS6513x Positive and Negative Output DC-DC
TPS6513x Positive and Negative Output DC-DC

... 7.1 Overview The TPS6513x operates with an input voltage range of 2.7 V to 5.5 V and can generate both a positive and negative output. Both converters work independently of each other. They only share a common clock and a common voltage reference. Both outputs are separately controlled by a fixed-fr ...
U100 Manual
U100 Manual

... .6'; Take care to ensure electromagnetic radiation from the inverter does not damage or effect the operation of nearby electrical equipment. .6'; Use an input line reactor when the power supply capacity is large. or where harmonics from the inverter will cause problems. .6'; Take countermeasures to ...
Leakage Current Modeling in PD SOI Circuits
Leakage Current Modeling in PD SOI Circuits

... Consider the inverter illustrated in Fig. 1, The floating body terminal of the nfet is capacitive coupled to its drain, source and gate terminals. Any variations in nfet source, drain and gate voltages also changes the body terminal voltage which in turn affects its device threshold voltage and the ...
Supply-Voltage Supervisor, TL7700 (Rev. G)
Supply-Voltage Supervisor, TL7700 (Rev. G)

... The TL7700 is a bipolar integrated circuit designed for use as a reset controller in microcomputer and microprocessor systems. The SENSE voltage can be set to any value greater than 0.5 V using two external resistors. The hysteresis value of the sense voltage also can be set by the same resistors. T ...
AAT3200 数据资料DataSheet下载
AAT3200 数据资料DataSheet下载

... For proper load voltage regulation and operational stability, a capacitor is required between pins VOUT and GND. The COUT capacitor connection to the LDO regulator ground pin should be made as direct as practically possible for maximum device performance. The AAT3200 has been specifically designed t ...
SLLIMM™ 2nd series small low-loss intelligent molded module
SLLIMM™ 2nd series small low-loss intelligent molded module

LTC3216 - 1A Low Noise High Current LED Charge Pump with
LTC3216 - 1A Low Noise High Current LED Charge Pump with

Lecture 9 – Low Power Design
Lecture 9 – Low Power Design

... • How many VDD? – Two is becoming common – Many chips already have two supplies (one for core and one for I/O) • When combining multiple supplies, level converters are required whenever a module at the lower supply drives a gate at the higher supply (step-up) – If a gate supplied with VDDL drives a ...
UEI25 Series - power, Murata
UEI25 Series - power, Murata

... Typical topology is shown. Murata Power Solutions recommends an external fuse. ...
AN4058, BLDC Motor Control with Hall Effect Sensors Using the
AN4058, BLDC Motor Control with Hall Effect Sensors Using the

... Figure 2. BLDC motor cross section ...
< 1 ... 194 195 196 197 198 199 200 201 202 ... 1089 >

Three-phase electric power



Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report