NDM2Z-12V
... Soft-stop Delay and Ramp Times After CTRL is de-asserted the NDM2Z-12 module utilizes a pre-ramp delay time before the output starts the rampdown process. After the delay period has expired, the output will begin to ramp towards ground according to the pre-configured soft-stop ramp time that has bee ...
... Soft-stop Delay and Ramp Times After CTRL is de-asserted the NDM2Z-12 module utilizes a pre-ramp delay time before the output starts the rampdown process. After the delay period has expired, the output will begin to ramp towards ground according to the pre-configured soft-stop ramp time that has bee ...
Morphology and electro-optic properties of polymer
... was modulated at 100 kHz by a photoelastic modulator between crossed polarizers, then made circularly polarized by a quarter-wave plate. The collection half-angle for the transmitted light was set to 1° by an iris. The forward-transmitted light was then focused by a lens onto a photodetector. The ph ...
... was modulated at 100 kHz by a photoelastic modulator between crossed polarizers, then made circularly polarized by a quarter-wave plate. The collection half-angle for the transmitted light was set to 1° by an iris. The forward-transmitted light was then focused by a lens onto a photodetector. The ph ...
Evaluation Board User Guide UG-310
... A standard oscilloscope probe has a long wire ground clip. For high frequency measurements, this ground clip picks up high frequency noise and injects it into the measured output ripple. Figure 2 shows an easy way to measure the output ripple properly. It requires removing the oscilloscope probe she ...
... A standard oscilloscope probe has a long wire ground clip. For high frequency measurements, this ground clip picks up high frequency noise and injects it into the measured output ripple. Figure 2 shows an easy way to measure the output ripple properly. It requires removing the oscilloscope probe she ...
Lexium™ 32i Integrated drives Motion control
... The modular product range: Lexium™ 32i integrated drives, features two communication interfaces for controlling Lexium BMI servo motors. These servo motors help to integrate the power stage that provides a direct power supply from either a single-phase or three-phase AC supply. This allows Lexium 32 ...
... The modular product range: Lexium™ 32i integrated drives, features two communication interfaces for controlling Lexium BMI servo motors. These servo motors help to integrate the power stage that provides a direct power supply from either a single-phase or three-phase AC supply. This allows Lexium 32 ...
microTimer User`s Manual
... connecting these leads together, with a stronger piece of wire looped around the breakwire and fixed to the ground. When the rocket leaves the pad, tension from the heavier wire snaps the breakwire, causing an open circuit condition. ...
... connecting these leads together, with a stronger piece of wire looped around the breakwire and fixed to the ground. When the rocket leaves the pad, tension from the heavier wire snaps the breakwire, causing an open circuit condition. ...
BD433/435/437 NPN Epitaxial Silicon Transistor BD433/435/437 — NPN Epit Features
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
LP3918 Battery Charge Management and
... interface. During power up LDO1 and LDO2 must reach their regulation voltage detection point for the device to power up and remain powered. LDO4, LDO5 and LDO6 have external enable pins and may power up following LDO2 as determined by their respective enable. Under voltage lockout oversees device st ...
... interface. During power up LDO1 and LDO2 must reach their regulation voltage detection point for the device to power up and remain powered. LDO4, LDO5 and LDO6 have external enable pins and may power up following LDO2 as determined by their respective enable. Under voltage lockout oversees device st ...
Handbook on Electricity Meters
... Phase angle - in degrees lead or lag Active power - in Watts (W) Reactive power - in Reactive Volt-Amperes (VARs) Apparent power - in Volt-Amperes (VA) Power factor - as a ratio or percent ...
... Phase angle - in degrees lead or lag Active power - in Watts (W) Reactive power - in Reactive Volt-Amperes (VARs) Apparent power - in Volt-Amperes (VA) Power factor - as a ratio or percent ...
MAX8830 LED Light Management IC in 2.5mm x 2.5mm UCSP General Description
... flash current and flash timer-duration settings, and individual current sink settings. Figure 1 shows the block diagram and typical application circuit. ...
... flash current and flash timer-duration settings, and individual current sink settings. Figure 1 shows the block diagram and typical application circuit. ...
A-2 CPO Preinstall
... Power Supply ........................................................................................................................................ 7 Customer Responsibility ......................................................................................................................... 7 ...
... Power Supply ........................................................................................................................................ 7 Customer Responsibility ......................................................................................................................... 7 ...
Proper Coil Drive is Critical to Good Relay and
... and release timing than in DC relays and often in increased contact or armature bounce or chatter. All this is dependent upon exactly where in the sine-wave the coil power is connected or removed and can even cause excessive contact bounce or chatter when initially operated. • As a result, AC relays ...
... and release timing than in DC relays and often in increased contact or armature bounce or chatter. All this is dependent upon exactly where in the sine-wave the coil power is connected or removed and can even cause excessive contact bounce or chatter when initially operated. • As a result, AC relays ...
Requirements concerning ELECTRICAL AND ELECTRONIC
... These test requirements are harmonised with IEC 60092-504 “Electrical Installations in Ships - Part 504: Special features - Control and Instrumentation” and IEC 60533 “Electrical and electronic installations in ships – electromagnetic compatibility”. Electrical and electronic equipment on board ship ...
... These test requirements are harmonised with IEC 60092-504 “Electrical Installations in Ships - Part 504: Special features - Control and Instrumentation” and IEC 60533 “Electrical and electronic installations in ships – electromagnetic compatibility”. Electrical and electronic equipment on board ship ...
LT3092 – 200mA 2-Terminal Programmable Current Source
... networks. In addition, the current source’s value will differ between applications and its connection may be GND referenced, power supply referenced or floating in a signal line path. Linear Technology strongly recommends that stability be tested in situ for any LT3092 application. In LT3092 applicat ...
... networks. In addition, the current source’s value will differ between applications and its connection may be GND referenced, power supply referenced or floating in a signal line path. Linear Technology strongly recommends that stability be tested in situ for any LT3092 application. In LT3092 applicat ...
Pac Tel Cover
... DEFINITION - TELEPHONE POWER Telephone power is all equipment in a toll or exchange central office or PBX that converts commercial alternating power to direct current at any required voltage, or A. C. power at various frequencies for ringing or signalling. At some locations where commercial power is ...
... DEFINITION - TELEPHONE POWER Telephone power is all equipment in a toll or exchange central office or PBX that converts commercial alternating power to direct current at any required voltage, or A. C. power at various frequencies for ringing or signalling. At some locations where commercial power is ...
Aalborg Universitet Power Control Flexibilities for Grid-Connected Multi-Functional Photovoltaic Inverters
... However, a considerably expanding installation of PV systems into the grid also brings side-effects on the entire distributed network due to the intermittent nature of solar PV energy (e.g., solar irradiance variations and temperature fluctuations, and thus fluctuating PV power), which will as a con ...
... However, a considerably expanding installation of PV systems into the grid also brings side-effects on the entire distributed network due to the intermittent nature of solar PV energy (e.g., solar irradiance variations and temperature fluctuations, and thus fluctuating PV power), which will as a con ...
BDTIC www.BDTIC.com/infineon F3L030E07-F-W2_EVAL Evaluation Board for Easy2B 3-Level Modules in
... The F3L030E07-F-W2_EVAL has two DC/DC converters, which generate four secondary isolated unipolar supply voltage sources of +15 V for each IGBT driver as shown in Figure 4. The driver voltages are independently generated by using one unipolar input voltage of +15 V. Furthermore, the power supplies a ...
... The F3L030E07-F-W2_EVAL has two DC/DC converters, which generate four secondary isolated unipolar supply voltage sources of +15 V for each IGBT driver as shown in Figure 4. The driver voltages are independently generated by using one unipolar input voltage of +15 V. Furthermore, the power supplies a ...
Performance Analysis of Double Inverter Fed Wound Rotor Induction
... systems. The slip energy recovery drives (SERD) known as Scherbius system [4], is low cost, simple control circuitry and high efficiency even at a low-speed range. A SERD transfers power that is normally wasted in the rotor of an induction machine back to the ac mains supply to improve overall drive ...
... systems. The slip energy recovery drives (SERD) known as Scherbius system [4], is low cost, simple control circuitry and high efficiency even at a low-speed range. A SERD transfers power that is normally wasted in the rotor of an induction machine back to the ac mains supply to improve overall drive ...
MAX9674 Evaluation Kit Evaluates: General Description Features
... The MAX9674 EV kit demonstrates the MAX9674 reference voltage generator for gamma correction in TFTLCD panels, such as those found in high-resolution TVs and high-end monitors, or for general-purpose industrial reference voltage generation. The EV kit provides a total of 17 programmable 10-bit-resol ...
... The MAX9674 EV kit demonstrates the MAX9674 reference voltage generator for gamma correction in TFTLCD panels, such as those found in high-resolution TVs and high-end monitors, or for general-purpose industrial reference voltage generation. The EV kit provides a total of 17 programmable 10-bit-resol ...
580393681ADM3202_22_1385_c.pdf
... the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance ...
... the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance ...
File
... conduction. Turn-off must be achieved in the anode-to-cathode circuit. There are three ways in which turn-off, or commutation as it is commonly called, can be achieved by: (1) reversing the anode-to-cathode voltage; (2) reducing the anode current below the holding current level; (3) forcing current ...
... conduction. Turn-off must be achieved in the anode-to-cathode circuit. There are three ways in which turn-off, or commutation as it is commonly called, can be achieved by: (1) reversing the anode-to-cathode voltage; (2) reducing the anode current below the holding current level; (3) forcing current ...
MAX1807/MAX1808 Micropower Adjustable Overvoltage Protection Controllers General Description
... The MAX1808 has a TH input that turns off the P-channel switch if TH goes below 1V without affecting the fault latch. TH output is designed for low-battery detection. The comparator has 10% hysteresis, allowing the battery voltage to rise when the load is removed without reenabling the external P-ch ...
... The MAX1808 has a TH input that turns off the P-channel switch if TH goes below 1V without affecting the fault latch. TH output is designed for low-battery detection. The comparator has 10% hysteresis, allowing the battery voltage to rise when the load is removed without reenabling the external P-ch ...
HIS – Highly Integrated Switchgear up to 550 kV, 63 kA
... Stored-energy spring mechanism The stored-energy spring mechanism provides the force required to operate the circuit breaker. It has a compact, corrosion-free aluminum housing. Both the opening and the closing spring are visibly arranged within the drive unit. The complete drive unit is strictly sep ...
... Stored-energy spring mechanism The stored-energy spring mechanism provides the force required to operate the circuit breaker. It has a compact, corrosion-free aluminum housing. Both the opening and the closing spring are visibly arranged within the drive unit. The complete drive unit is strictly sep ...
File - Tek finland oy
... of a device of which it’s made, such as the series resistance, threshold voltage, capacitance, and other parameters. ...
... of a device of which it’s made, such as the series resistance, threshold voltage, capacitance, and other parameters. ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.