Alberta Reliability Standard Cyber Security – BES Cyber System Categorization CIP-002-AB-5.1
... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate highest rated net maximum authorized real power capabilityrating of each of the preceding 12 monthsgenerating units minus the station service load equal to or ...
... commissioned generation, by each group of generating units or aggregated generating facilities at a single plant location, with an aggregate highest rated net maximum authorized real power capabilityrating of each of the preceding 12 monthsgenerating units minus the station service load equal to or ...
SP3220E 数据资料DataSheet下载
... Voltage potential across any of the capacitors will never exceed 2 x VCC. Therefore capacitors with working voltages as low as 6.3V rating may be used with a 3.0V VCC supply. The reference terminal of the V+ capacitor may be connected either to VCC or ground, but if connected to ground a minimum 10V ...
... Voltage potential across any of the capacitors will never exceed 2 x VCC. Therefore capacitors with working voltages as low as 6.3V rating may be used with a 3.0V VCC supply. The reference terminal of the V+ capacitor may be connected either to VCC or ground, but if connected to ground a minimum 10V ...
Alberta Reliability Standard – BES Cyber System Categorization Cyber Security CIP-002-AB-5.1
... substation, where the station or substation is connected at 200 kV or higher voltages to three or more other transmission stations or substations and has an "aggregate weighted value" exceeding 3000 according to the table below. The "aggregate weighted value" for a single station or substation is de ...
... substation, where the station or substation is connected at 200 kV or higher voltages to three or more other transmission stations or substations and has an "aggregate weighted value" exceeding 3000 according to the table below. The "aggregate weighted value" for a single station or substation is de ...
PAM2301 Description Pin Assignments
... In continuous mode, the source current of the top MOSFET is a square wave of duty cycle VOUT/VIN. To prevent large voltage transients, a low ESR input capacitor sized for the maximum RMS current must be used. The maximum RMS capacitor current is given by: ...
... In continuous mode, the source current of the top MOSFET is a square wave of duty cycle VOUT/VIN. To prevent large voltage transients, a low ESR input capacitor sized for the maximum RMS current must be used. The maximum RMS capacitor current is given by: ...
Inductors - Oregon State University
... and represent an increasing opposition to AC currents of increasing frequency (called reactance), they make excellent frequency filters. For example in a sub-woofer speaker system, the deep base speaker must only see the lowest frequencies. A filter, a cross-over network using inductors is typically ...
... and represent an increasing opposition to AC currents of increasing frequency (called reactance), they make excellent frequency filters. For example in a sub-woofer speaker system, the deep base speaker must only see the lowest frequencies. A filter, a cross-over network using inductors is typically ...
AP2331 0.2A SINGLE CHANNEL CURRENT-LIMITED LOAD SWITCH Description
... internal power switch is initially off during start-up. The UVLO functions only when the power supply has reached at least 2.5V (TYP). Whenever the input voltage falls below approximately 2.5V, the power switch is turned off. This facilitates the design of hot-insertion systems where it is not possi ...
... internal power switch is initially off during start-up. The UVLO functions only when the power supply has reached at least 2.5V (TYP). Whenever the input voltage falls below approximately 2.5V, the power switch is turned off. This facilitates the design of hot-insertion systems where it is not possi ...
Leroy Somer – LSA 47.2 VS2
... Check that: - The residual circuit-breaker conforms to legislation on protection of personnel, in force in the country of use, and has been correctly installed on the alternator power output as close as possible to the alternator. (In this case, disconnect the wire of the interference suppression mo ...
... Check that: - The residual circuit-breaker conforms to legislation on protection of personnel, in force in the country of use, and has been correctly installed on the alternator power output as close as possible to the alternator. (In this case, disconnect the wire of the interference suppression mo ...
BU4S01G2
... Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect ...
... Input pins of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect ...
HB1 and VB1 Generator Circuit-Breaker Switchgear
... are subject to conditions quite different from those of normal distribution circuit-breakers used in industrial, commercial and utility systems. ...
... are subject to conditions quite different from those of normal distribution circuit-breakers used in industrial, commercial and utility systems. ...
133-08AY08(circ1)
... axes. With the switch open (e.g. no current flow), click the "Zero" icon near the top of the screen, and follow the on-screen directions to "zero" or "reset" the current probes. Now, click the green "Collect" button near the top of the screen. Data should start appearing toward the right. While taki ...
... axes. With the switch open (e.g. no current flow), click the "Zero" icon near the top of the screen, and follow the on-screen directions to "zero" or "reset" the current probes. Now, click the green "Collect" button near the top of the screen. Data should start appearing toward the right. While taki ...
Datasheet - Texas Instruments
... This pin configures the output startup mode. If the SEQ pin is connected to BP, then when Output 2 is enabled, Output 1 is allowed to start after Output 2 has reached regulation; that is, sequential startup where Output 1 is slave to Output 2. If EN2 is allowed to go high after the outputs have been ...
... This pin configures the output startup mode. If the SEQ pin is connected to BP, then when Output 2 is enabled, Output 1 is allowed to start after Output 2 has reached regulation; that is, sequential startup where Output 1 is slave to Output 2. If EN2 is allowed to go high after the outputs have been ...
FEATURES DESCRIPTION D
... voltage-feedback amplifier with a very low input noise voltage and high output current using a low 5.7mA/ch supply current. At unity-gain, the OPA4820 gives > 600MHz bandwidth with < 1 dB peaking. The OPA4820 complements this high-speed operation with excellent DC precision in a low-power device. A ...
... voltage-feedback amplifier with a very low input noise voltage and high output current using a low 5.7mA/ch supply current. At unity-gain, the OPA4820 gives > 600MHz bandwidth with < 1 dB peaking. The OPA4820 complements this high-speed operation with excellent DC precision in a low-power device. A ...
Agilent E3631A doc
... state of the disabled outputs is a condition of less than 0.6 volts of opposite polarity with no load and less than 60 mA of opposite direction with a short circuit. At *RST, the output state is off. OUTPut[:STATe]? ...
... state of the disabled outputs is a condition of less than 0.6 volts of opposite polarity with no load and less than 60 mA of opposite direction with a short circuit. At *RST, the output state is off. OUTPut[:STATe]? ...
Advances in Environmental Biology
... by them, which is called Micro-Grid (MG) and in MV level is called Grid Cell. Micro-grids are networks that are formed by coming together of LV network, loads, small production units, control networks, storage networks, and adapters, which provide a little load in their area; by connecting many smal ...
... by them, which is called Micro-Grid (MG) and in MV level is called Grid Cell. Micro-grids are networks that are formed by coming together of LV network, loads, small production units, control networks, storage networks, and adapters, which provide a little load in their area; by connecting many smal ...
AAT2606 数据资料DataSheet下载
... For proper load voltage regulation and operational stability, a capacitor is required between the VOUT and GND pins. The COUT capacitor connection to the LDO regulator ground pin should be made as direct as practically possible for maximum device performance. The AAT2606 LDO regulators have been spe ...
... For proper load voltage regulation and operational stability, a capacitor is required between the VOUT and GND pins. The COUT capacitor connection to the LDO regulator ground pin should be made as direct as practically possible for maximum device performance. The AAT2606 LDO regulators have been spe ...
optional
... This manual has been carefully checked. However, Axor does not assume liability for errors or inaccuracies. Print in Italy 02/2008 ...
... This manual has been carefully checked. However, Axor does not assume liability for errors or inaccuracies. Print in Italy 02/2008 ...
IEEE 802.3at PoE High-Power PD Interface with External Gate Driver
... to as type 2 devices. Standards change and should always be referenced when making design decisions. The IEEE 802.3at standard defines a method of safely powering a PD (powered device) over a cable by power sourcing equipment (PSE), and then removing power if a PD is disconnected. The process procee ...
... to as type 2 devices. Standards change and should always be referenced when making design decisions. The IEEE 802.3at standard defines a method of safely powering a PD (powered device) over a cable by power sourcing equipment (PSE), and then removing power if a PD is disconnected. The process procee ...
BD9535MUV
... ultra high transient response against load change. SLLM (Simple Light Load Mode) technology is also integrated to improve efficiency in light load mode, providing high efficiency over a wide load range. For the soft start/stop function, variable frequency function, short circuit protection function ...
... ultra high transient response against load change. SLLM (Simple Light Load Mode) technology is also integrated to improve efficiency in light load mode, providing high efficiency over a wide load range. For the soft start/stop function, variable frequency function, short circuit protection function ...
Lexium™ 32i Integrated drives Motion control
... The modular product range: Lexium™ 32i integrated drives, features two communication interfaces for controlling Lexium BMI servo motors. These servo motors help to integrate the power stage that provides a direct power supply from either a single-phase or three-phase AC supply. This allows Lexium 32 ...
... The modular product range: Lexium™ 32i integrated drives, features two communication interfaces for controlling Lexium BMI servo motors. These servo motors help to integrate the power stage that provides a direct power supply from either a single-phase or three-phase AC supply. This allows Lexium 32 ...
AN11119 Medium power small-signal MOSFETs in DC-to-DC conversion
... In modern electronic designs various supply voltages need to be generated. In most cases power supply provides one or a few different DC voltages. These voltages need to be converted to another voltage for several functional units in the application. Voltage conversion can work in both directions: i ...
... In modern electronic designs various supply voltages need to be generated. In most cases power supply provides one or a few different DC voltages. These voltages need to be converted to another voltage for several functional units in the application. Voltage conversion can work in both directions: i ...
Motor Mounted Components - Altra Literature Portal
... MA: locked rotor torque of the motor; ML: load torque; MBr: braking torque As can be seen, there is an additional load on the motor and brake in both cases. The effect of the response time increases with increasing brake size. Consequently, it is advisable to reduce the response time, especially wit ...
... MA: locked rotor torque of the motor; ML: load torque; MBr: braking torque As can be seen, there is an additional load on the motor and brake in both cases. The effect of the response time increases with increasing brake size. Consequently, it is advisable to reduce the response time, especially wit ...
microTimer User`s Manual
... connecting these leads together, with a stronger piece of wire looped around the breakwire and fixed to the ground. When the rocket leaves the pad, tension from the heavier wire snaps the breakwire, causing an open circuit condition. ...
... connecting these leads together, with a stronger piece of wire looped around the breakwire and fixed to the ground. When the rocket leaves the pad, tension from the heavier wire snaps the breakwire, causing an open circuit condition. ...
Three-phase electric power
Three-phase electric power is a common method of alternating-current electric power generation, transmission, and distribution. It is a type of polyphase system and is the most common method used by electrical grids worldwide to transfer power. It is also used to power large motors and other heavy loads. A three-phase system is usually more economical than an equivalent single-phase or two-phase system at the same line to ground voltage because it uses less conductor material to transmit electrical power.The three-phase system was independently invented by Galileo Ferraris, Mikhail Dolivo-Dobrovolsky, Jonas Wenström and Nikola Tesla in the late 1880s.