• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2 A max constant current LED driver
2 A max constant current LED driver

1 - gcisd
1 - gcisd

Temperature measurements with resistance thermometer General
Temperature measurements with resistance thermometer General

... to the tube axis or in pipe bends. In this case, the thermometer group is always installed against the flow direction. The table provides information on the installation length in a pipe of a given diameter. 1/3 DIN B (AA) = ± 0,10% at 0°C = 1/3 von Class B During the actual measurement process, it ...
FM50 - uri=media.digikey
FM50 - uri=media.digikey

... driving a P-channel load. Available current is typically 50μA to ground. Series resistance is typically 7kΩ, charging and 2kΩ, discharging through a capacitor connected from VOUT to ground. ...
BAW56 Small Signal Diode
BAW56 Small Signal Diode

... 2. A critical component is any component of a life systems which, (a) are intended for surgical implant into support device or system whose failure to perform can the body, or (b) support or sustain life, or (c) whose be reasonably expected to cause the failure of the life failure to perform when pr ...
Voltage - LCNeuro
Voltage - LCNeuro

... ● Current is the flow of electrons. It is the speed of the electrons. ● Current is measured in Amperes (Amps, A). ● 1 Ampere = 6.24 quintillion electrons travelling through a single point per second. ...
Chemistry 1: Second Semester Practice Exam Read each question
Chemistry 1: Second Semester Practice Exam Read each question

BAS21 General Purpose High Voltage Diode
BAS21 General Purpose High Voltage Diode

Sample ELEC 311 Final Questions
Sample ELEC 311 Final Questions

Worcester Polytechnic Institute
Worcester Polytechnic Institute

Technical Article Technical Article
Technical Article Technical Article

$doc.title

... Thermal Clad. Using a board material such as Thermal Clad, an aluminum core board, the power dissipation can be doubled using the same footprint. ...
EGH 681: Room transducer, relative humidity and temperature
EGH 681: Room transducer, relative humidity and temperature

Lecture 8 - UConn Physics
Lecture 8 - UConn Physics

... • Two cylindrical resistors, R1 and R2, are made of identical material. R2 has twice the length of R1 but half the radius of R1. – These resistors are then connected to a battery V as shown: I1 ...
Lecture 8 - UConn Physics
Lecture 8 - UConn Physics

Technical specifications and dimensions Moon by City Design is a
Technical specifications and dimensions Moon by City Design is a

TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS

... Thermal Testing Setup Delta’s filter modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mount ...
Slide 1
Slide 1

... This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their courses and assessing student learning. Dissemination or sale of any part of this work (including on the World Wide Web) will destroy the integrity of the work and is not permit ...
Electric circuits - World of Teaching
Electric circuits - World of Teaching

... one continuous ‘loop’ The current is the same anywhere in the circuit An ammeter can be placed anywhere in the circuit If we get one gap in the circuit the current stops flowing ...
Electronics and Noise
Electronics and Noise

Lab-12 Stephan-Boltzmann Law
Lab-12 Stephan-Boltzmann Law

Theory
Theory

How to Make Linear Mode Work
How to Make Linear Mode Work

LED570-06
LED570-06

Lecture4_oim - Nuclear Physics Group
Lecture4_oim - Nuclear Physics Group

... the Greek letter tau τ known as the time constant. τis the amount of time it takes for the temperature difference to decrease by a factor of e = 2.7183 ...
< 1 ... 286 287 288 289 290 291 292 293 294 ... 327 >

Thermal runaway



Thermal runaway refers to a situation where an increase in temperature changes the conditions in a way that causes a further increase in temperature, often leading to a destructive result. It is a kind of uncontrolled positive feedback.In other words, ""thermal runaway"" describes a process which is accelerated by increased temperature, in turn releasing energy that further increases temperature. In chemistry (and chemical engineering), this risk is associated with strongly exothermic reactions that are accelerated by temperature rise. In electrical engineering, thermal runaway is typically associated with increased current flow and power dissipation, although exothermic chemical reactions can be of concern here too. Thermal runaway can occur in civil engineering, notably when the heat released by large amounts of curing concrete is not controlled. In astrophysics, runaway nuclear fusion reactions in stars can lead to nova and several types of supernova explosions, and also occur as a less dramatic event in the normal evolution of solar mass stars, the ""helium flash"".There are also concerns regarding global warming that a global average increase of 3-4 degrees Celsius above the preindustrial baseline could lead to a further unchecked increase in surface temperatures. For example, releases of methane, a greenhouse gas more potent than CO2, from wetlands, melting permafrost and continental margin seabed clathrate deposits could be subject to positive feedback.
  • studyres.com © 2025