• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Gate Tunable MoS -based Thermoelectric Devices Morteza Kayyalha and
Gate Tunable MoS -based Thermoelectric Devices Morteza Kayyalha and

Example #1: A 10 ampere current flows through a wire in 60
Example #1: A 10 ampere current flows through a wire in 60

... Example #15: An electric fan draws 2.0 A of current from a 120 V source. Determine the following: (a) the power rating of the fan. (b) its electrical resistance. (c) the cost of operation of the fan during the month of August, assuming it is run continuously and electric energy costs 10 cents per k ...
The high power version of the WS19
The high power version of the WS19

... battery connector, the Aerial Tuning Inductance No.1 and the aerial isolation capacitor. In practice the last two items are not essential. The tuning inductor, a roller-coaster type variable inductor designed to handle higher power levels than the variometer, is only needed for resonating short ante ...
5: Electric Current
5: Electric Current

Lecture 6 Slides - Digilent Learn site
Lecture 6 Slides - Digilent Learn site

... Practical application – temperature measurement • Design a temperature measurement system whose output voltage increases as temperature increases • In general, we will typically have other design objectives • For example, power and sensitivity requirements • We neglect these for now; lab 2 will pro ...
2N3904
2N3904

... 1. Life support devices or systems are devices or 2. A critical component is any component of a life systems which, (a) are intended for surgical implant into support device or system whose failure to perform can the body, or (b) support or sustain life, or (c) whose be reasonably expected to cause ...
SG-02-0062 A1 KCCA0039 Series Motor
SG-02-0062 A1 KCCA0039 Series Motor

... controller begins providing voltage to the motor at a minimum duty cycle of 7.0%. The duty cycle increases linearly with speed input voltage up to 3.86 volts at which point the duty cycle is 100%. If the controller measures 4.6 volts or more on the speed control input, or 5.6 volts or more on the sp ...
Major Megger Insulation Resistance Testers
Major Megger Insulation Resistance Testers

... measurement readout and an external guard terminal to eliminate surface leakage current from the measurement. Five models are available for general purpose testing which include a low-voltage model. All are portable, self-contained instruments designed to give rapid and accurate measurements. Four o ...
1.a) Discuss and draw in details each of the following: 1
1.a) Discuss and draw in details each of the following: 1

... Xp and Xs are the leakage reactances of the primary and secondary windings, and also for the resistances Rp and Rs. Rs and Xs are connected in series with the secondary. The load current causes a voltage drop across Rs and Xs. Similarly, Rp and Xp are connected in series with the primary windings, a ...
SPT601 - ssousa.com
SPT601 - ssousa.com

... SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from ...
Lecture 6 slides
Lecture 6 slides

... Practical application – temperature measurement • Design a temperature measurement system whose output voltage increases as temperature increases • In general, we will typically have other design objectives • For example, power and sensitivity requirements • We neglect these for now; lab 2 will pro ...
An introduction to AC/DC power supply as a simple system
An introduction to AC/DC power supply as a simple system

... power line. Alternately, the input may be 240 volt AC. The power supply converts the AC into DC and provides one or more DC output voltages. Some modern electronic circuits need two or more different voltages. Common voltages are 48, 24, 15, 12, 9, 5, 3.3, 2.5, 1.8, 1.5, 1.2 and 1 volts. A good exam ...
inverter - Gustav Klein
inverter - Gustav Klein

... our own printed-circuit design and our own software programming department, emphasise our continuously innovative activities. ...
Common Power Problems - A-TRAC
Common Power Problems - A-TRAC

... the ideal power protection with a wide range of voltages, frequencies, runtimes, power cords and receptacles. These units provide power protection with ferroresonant technology and are recommended for applications like midrange computers, internetworking equipment, PBX and communications systems and ...
UML1N
UML1N

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
Power Electronics
Power Electronics

... The effective value of output voltage (or fundamental output voltage) can be changed by changing Ud. ...
Parallel Circuits
Parallel Circuits

... •They have no effect on each other. ...
Transformer Basics
Transformer Basics

... taps. It also verifies taps are correctly brought out to the CT terminal blocks. ...
62-814.450 Electric and Magnetic Field Standards.
62-814.450 Electric and Magnetic Field Standards.

... evidence of biological effects and a potential for adverse health effects on the public, no conclusive evidence that there is any danger or hazard to public health at the levels of electric and magnetic fields permitted by the standards set forth in this chapter. (b) With respect to 60 hertz EMF, re ...
Document
Document

... Therefore, (vCa)peak ≈ 196+6.85=202.85 V. Because the system is balanced, the peak value should be the same for all phases. The required dc voltage should be Vdc ≥ 2(vCa ) peak = 405.7 V for the triangular-wave PWM or Vdc ≥ 3 (vCa ) peak = 351.35 V for the space vector PWM. 2. The instantaneous real ...
TeraOhm 5 kV - Emona Instruments
TeraOhm 5 kV - Emona Instruments

... – Pre-set DC test voltages 250 V ÷ 5000 V in steps of 50 V. Ω – Measuring range up to 5 TΩ – Timer mode from 1 s up to 30 min. – Capacitance measurement up to 50 µF. Powerful feature of Diagnostic tests: – Discharge Current, Voltage and Capacitance measured on the equipment under test. – Polarizatio ...
exploring circuits
exploring circuits

... this type of electrical circuit is that if there is a break in any part of it, then the entire circuit is opened and therefore will not allow an electrical current to flow. The second type of electrical circuit is a parallel circuit. In a parallel circuit the different electrical parts are located o ...
Series 1654 - Wilmore Electronics
Series 1654 - Wilmore Electronics

... The Model 1654 rack-mount inverter provides 1000 volt-amperes of 120-Vac, 60-Hz output power in only 3.5 inches of vertical rack space. Standard versions allow operation from 24-Vdc, 48-Vdc or 130-Vdc battery sources. The well-regulated, frequency-stable quasi-sinewave output is well-suited for powe ...
Bipolar Power Transistor 30V 1.5A PNP PCP
Bipolar Power Transistor 30V 1.5A PNP PCP

... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
BSPM2275TN(R) / BSPH2275TT(R)
BSPM2275TN(R) / BSPH2275TT(R)

... The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information th ...
< 1 ... 977 978 979 980 981 982 983 984 985 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report