• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Development Board EPC9006C - Rev. 3.0 Quick Start Guide
Development Board EPC9006C - Rev. 3.0 Quick Start Guide

Industrial Control Equipment – UL 508 - Industries
Industrial Control Equipment – UL 508 - Industries

SEP Energymeter - Mindsets Online
SEP Energymeter - Mindsets Online

... Different measurements can be made by pressing the function button to cycle through the following four settings: ...
EB25778783
EB25778783

PSpice - Time Domain Analysis
PSpice - Time Domain Analysis

... the capacitance and the initial voltage of the capacitor (the “Initial Condition”). For the inductor on the other hand, the part properties of interest are the inductance and the initial current of the inductor (the “Initial Condition”). In this lab we consider three examples. The first example illu ...
Power Sources On The Car ELECTRICAL
Power Sources On The Car ELECTRICAL

... "Electronic" devices and systems provide today's vehicles with added comfort, convenience, safety, and performance. These devices and systems, like their "electrical" counterparts, control electricity to do work. The current flows through a semiconductor - rather than through wires. The movement usu ...
Electricity03
Electricity03

stripfet iii and optimal choice of mosfets in high current vrms
stripfet iii and optimal choice of mosfets in high current vrms

The Transistor
The Transistor

... Building Fucnctions from Logic Gates Combinational Logic Circuit  output depends only on the current inputs  stateless Sequential Logic Circuit  output depends on the sequence of inputs (past and present)  stores information (state) from past inputs ...
Installation and Operation Instructions ATL
Installation and Operation Instructions ATL

report - Auburn Engineering
report - Auburn Engineering

Electronic Troubleshooting
Electronic Troubleshooting

... • Bridge suspected filtering Cap with a known good one of approximately the same rated value • If the ripple problems decrease – replace the capacitor ...
integration of multiple renewable energy sources for dc microgrid
integration of multiple renewable energy sources for dc microgrid

Stresa, Italy, 26-28 April 2006
Stresa, Italy, 26-28 April 2006

... devices. However, obtaining a high damping force can be difficult with piezoelectric devices operating at low frequency due to internal leakage, and to limitations on the practical geometry and dimensions, most such devices using bimorph cantilevers. Unlike the electromagnetic and electrostatic case ...
Emf and Internal Resistance
Emf and Internal Resistance

V. C. Summer Nuclear Station, Units 2 and 3 COL Application
V. C. Summer Nuclear Station, Units 2 and 3 COL Application

... centers. The VCSNS Units 2 and 3 switchyard is tied to the following 230 kV transmission systems: SCE&G, Santee Cooper, and Duke Energy. The interconnection of Units 2 and 3, the switchyard, and the 230kV transmission lines are shown on Figure 8.2-201. There are 12 overhead transmission lines connec ...
Homework #3 Solution
Homework #3 Solution

... =20log10|200/14m|=83dB ...
Year 9 Homework Task 7J-5 Electric Circuits 5
Year 9 Homework Task 7J-5 Electric Circuits 5

Step-Down Converter Operates from Single Li-Ion Cell
Step-Down Converter Operates from Single Li-Ion Cell

... The circuit of Figure 3 shows the LTC1626 being used for board-level conversion of 5V to 3.3V at up to 0.6A. Although a linear regulator could also perform this function, it would result in an additional 1W of power loss. The high efficiency of the LTC1626 (Figure 4) reduces this loss to only 230mW. ...
Electrical_Engineeri.. - Engineers Institute of India
Electrical_Engineeri.. - Engineers Institute of India

Multilayer Varistor General Information
Multilayer Varistor General Information

... It is an exponentially decaying positive voltage that occurs in the event of a battery disconnect while the alternator is still generating charging current, with other loads remaining on the alternator circuit at the time of battery disconnect. Maximum peak current that may be applied to the varisto ...
T3300 Voltage Relay
T3300 Voltage Relay

... pick-up level, and another LED indicates at over voltage pick-up level. Also two LEDs indicate when the respective output relays are operated on fault level. The green power LED indicates when the voltage relay is on power. The connection diagram shows the system de-energized. ...
CN0233: 16位工业、隔离电压电流输出的DAC,同时提供隔离的DC-DC电源 .
CN0233: 16位工业、隔离电压电流输出的DAC,同时提供隔离的DC-DC电源 .

... Solutions based on opto-isolators typically have reasonable output regulation but require additional external components, thereby increasing board area. Power modules are often bulky and may provide poor output regulation. The circuit in Figure 1 is based on the ADuM347x family of isolators (ADuM347 ...
White Paper # 207
White Paper # 207

... “noisy” electrical ground connection at any point between the appliance and the power source. At the main distribution panelboard, this isolated grounding conductor must attach to a point that is electrically the same as the building’s first neutral to ground bonding point. At the appliance or load ...
AND8019/D Offline Converter Provides 5.0 Volt, 1.0 Amp
AND8019/D Offline Converter Provides 5.0 Volt, 1.0 Amp

... ON Semiconductor’s NCP1000 series of offline converters offers a low cost, high efficiency power source for low power, electronic equipment. It serves the same function as small, line frequency transformers, but with the added benefits of line and load regulation, transient suppression, reduction in ...
< 1 ... 907 908 909 910 911 912 913 914 915 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report