• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MODEL 257 3-Phase Monitor
MODEL 257 3-Phase Monitor

... correct, rotate the level adjustment counter-clockwise. If the contact still does not transfer, remove power and reverse two of the three phase wires at the socket (phase rotation is reversed). Re-apply power. The contact should transfer to provide a signal path between pins 1 and 8. NOTE: When inst ...
系统功能
系统功能

... B) Make sure the inverter’s AC voltage and frequency is the same with power grid voltage and frequency. C)Installation inverter in the low humidity and well-ventilated place to avoid the inverter damp and overheating, And clear the inflammable and explosive materials around. E)Recommended to use 4AW ...
Guide Specification for Ashley-Edison SES Single Phase AC
Guide Specification for Ashley-Edison SES Single Phase AC

... This specification covers the electrical aspects for a Rack Mountable AC Voltage Stabiliser / Converter that shall provide automatically stabilized and regulated power to sensitive electrical and electronic equipment. The Stabiliser should be based on the Servo Electronic design principle comprising ...
Lecture-9
Lecture-9

... The design is such that the air expands into the low pressure (atmospheric pressure zone).The air at high speed removes heat from the arc, thus arc is quenched. Diameter of arc is reduced. ...
Control Circuit Transients - GE Grid Solutions Online Store
Control Circuit Transients - GE Grid Solutions Online Store

... circuit. In this circuit the total self inductance of the loop in the vertical plane between the CT’s is represented by L1 and L2 in series, as shown. The bushing capacitances of the CT’s are CA and CE. The capacitance across the open circuit breaker (the built-in voltage equalizing capacitors) is C ...
Switchgear & Protection
Switchgear & Protection

... secondary voltage must be accurate representation of the primary voltage in both magnitude and phase. To meet this requirement, they are designed to operate at low flux densities so that Ie , ration and phase angle errors are small. This larger than that of power transformer, which increase the over ...
8.3 Electrical Current 2
8.3 Electrical Current 2

... • An electrical current is measured with a device called an ammeter. This device records the number of charges passing through it per second. Specifically, a current of 1 ampere (amp) is a flow past a point of 1 coulomb of charge per second (1 A = 1C/s). The ampere is named in honor of Andre-Marie A ...
6-VOLT XR Series - Chicago Code -Sealed Lead Calcium and Sealed Nickel Cadmium
6-VOLT XR Series - Chicago Code -Sealed Lead Calcium and Sealed Nickel Cadmium

... Sure-Lites sealed nickel cadmium batteries are maintenance free and utilize positive and negative sintered plate construction with polypropylene separators offering high discharge capability and stable performance over a wide range of temperatures. The specially designed resealable vent automaticall ...
FormatOfPapers
FormatOfPapers

... Mathematically, feedback linearization reduces the complexity of the corresponding analysis and design. However, even from mathematical standpoints, the simplification and "optimum" performance would be achieved in expense of large control efforts required because of linearizing feedback (25). This ...
Three Phase Three Level DC/DC Converter Using Active
Three Phase Three Level DC/DC Converter Using Active

... An active snubber, which consists of an active switch and a capacitor, has to switch at twice the switching frequency and at the full power of the main dc/dc converter. This Active Clamp Technology will reduce the duty cycle losses. It reduces the number of switches, the gate drivers, and PWM channe ...
Inside an AC LED Module How Acrich2 Modules Operate
Inside an AC LED Module How Acrich2 Modules Operate

... until the voltage reaches its peak. As the voltage decreases, the LEDs turn off in reverse order with the cycle repeating at twice the input voltage frequency. The proper matching of the LED array voltage to the input voltage for each voltage step produces excellent power factor, low total harmonic ...
6-pin dip zero-cross optoisolators triac driver output
6-pin dip zero-cross optoisolators triac driver output

Datasheet - DE-SWADJ
Datasheet - DE-SWADJ

... DE-SWADJ Adjustable Switching Voltage Regulator General Description The DE-SWADJ is designed to be the easiest possible way to utilize the benefits of switchmode power when you need an unusual or easily changed voltage. The DE-SWADJ family is pin-compatible with the common 78XX family of linear volt ...
ED EX 702QUES - St. Aloysius Institute of Technology, Jabalpur
ED EX 702QUES - St. Aloysius Institute of Technology, Jabalpur

... Answer:Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element. 16. whats the one main difference ...
Vintage Guitar Review - May 2015
Vintage Guitar Review - May 2015

... units, the XW-1 is refined and oh-so smart. Its talents include an active two-band EQ, biasing and Q control, true-bypass switching, and a self-lubricating pivot – all within a smaller footprint. That self-lubricating nylon bushing pivot is invaluable. Many a wah that goes south is opened up to reve ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... increased. In SPWM technique we follow the same procedure to make pulsating wave signal in which width of each pulse varied according to same fashion as follow by sine wave magnitude. In the most straightforward implementation, generation of the desired output voltage is achieved by comparing the de ...
DSL  Primary Switched Battery Charging and Power Supply Unit GL4024
DSL Primary Switched Battery Charging and Power Supply Unit GL4024

K046065864
K046065864

Diris A40
Diris A40

... V3, P, Q, S, PFL/C and F. Possible to use 4-20 mA in auxiliary supply 30 V DC for metering inputs. - Communication with JBUS/MODBUS protocol (up to 38400 bauds in RTU mode and via functions 3, 6, 8 and 16), and a three-wire (+, - and 0V) RS485 enabling remote viewing and configuration. - Communi ...
REL 512 CT Circuit Current Rating
REL 512 CT Circuit Current Rating

... If it is more convenient, modification can be done on-site in the field. The PC board will not be replaced. However, reconnection to the board is made to prevent the board traces from carrying the CT current. The relay front panel and top cover must be removed so that appropriate access to the inter ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

Isobar 8-Outlet Professional A/V Power Conditioning
Isobar 8-Outlet Professional A/V Power Conditioning

... Built-in splitter (1 jack in/2 jacks out) allows simultaneous connection of two devices sharing a single line Input Voltage LCD meter displays the in-coming utility power with dimmer control. Alerts user to input voltage levels ...
Demonstration of Using Flywheels and FACTS Control for Transient Stabilization and
Demonstration of Using Flywheels and FACTS Control for Transient Stabilization and

PSpice - Time Domain Analysis
PSpice - Time Domain Analysis

... the capacitance and the initial voltage of the capacitor (the “Initial Condition”). For the inductor on the other hand, the part properties of interest are the inductance and the initial current of the inductor (the “Initial Condition”). In this lab we consider three examples. The first example illu ...
Industrial Control Equipment – UL 508 - Industries
Industrial Control Equipment – UL 508 - Industries

< 1 ... 906 907 908 909 910 911 912 913 914 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report