• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Final Presentation
Final Presentation

746KB - Yaskawa
746KB - Yaskawa

Understanding The Functions Of Filter Capacitor In
Understanding The Functions Of Filter Capacitor In

... be removed. The AC has been converted into a smooth DC. If the filter capacitors fail either increase in ESR reading or lose some of its capacitance, the AC signal will be allowed to remain with the DC, creating a signal which is noisier than it should it. This unwanted noise signal can cause proble ...
Minimizing the SET-related effects on the output of a voltage linear
Minimizing the SET-related effects on the output of a voltage linear

Lab 8 - facstaff.bucknell.edu
Lab 8 - facstaff.bucknell.edu

... the two ends of a given winding. A transformer with a center tap (half-way between the two ends) on one winding is depicted in Figure 3b. Note that in a 1:1 transformer the voltage between one end of a winding and a center tap is half that applied to the other winding. This is because the number of ...
PDF
PDF

PDF
PDF

... +24VDC ...
D44H11
D44H11

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits
Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits

... The charger for a cell phone contains a transformer that reduces 120-V ac to 5.0-V ac to charge the 3.7-V battery. (It also contains diodes to change the 5.0-V ac to 5.0-V dc.) Suppose the secondary coil contains 30 turns and the charger supplies 700 mA. Calculate (a) the number of turns in the prim ...
20KW - JC Moss Electric
20KW - JC Moss Electric

... •Programmable seven day exerciser ...
Noise Interference
Noise Interference

... G Cameron Telecom NZ Ltd ...
485 Picoammeter
485 Picoammeter

... The output voltage of the op amp is precisely related to the input current. Since input voltage is output voltage divided by op amp gain (typically 100,000), the voltage burden is only microvolts. The maximum specified voltage burden of the 485 is only 0.2mV. An example of the problems caused by hig ...
DN137 - New Comparators Feature Micropower Operation Under All Conditions
DN137 - New Comparators Feature Micropower Operation Under All Conditions

... Under All Conditions – Design Note 137 Jim Williams Some micropower comparators have operating modes that allow excessive current drain. In particular, poorly designed devices can conduct large transient currents during switching. Such behavior causes dramatically increased power drain with rising f ...
Bip Transistor 25V 700mA VCE(sat);25mV(max.) NPN Single PCP
Bip Transistor 25V 700mA VCE(sat);25mV(max.) NPN Single PCP

... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
BU941ZP
BU941ZP

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
Performance Evaluation of Fuzzy
Performance Evaluation of Fuzzy

... controllers' schemes are validated under this condition in order to show their capability in keeping the STATCOM stable for a power system. The digital simulation for the study system shown in Fig. 6 is carried out again under the same load excursions but using the Fuzzy logic controller. This new c ...
docx - Energy Rating
docx - Energy Rating

... type and dry-type distribution transformers, both single and three phase:  with power ratings between 10 and 2500 KVA;  with a system highest voltage of 24 kV; and  that are designed for 11 or 22kV networks. This covers transformers installed both in public and privately owned electrical distribu ...
Improved Interline Unified Power-Quality Conditioner with
Improved Interline Unified Power-Quality Conditioner with

... Thus we take the problems in the distribution system and reduce the effect and causing good power quality in the system with our Interline Unified Power Quality Conditioner as to make our distribution system provides the good quality of power to our consumers and to get the system to the stability. ...
I 2
I 2

... •Can easily get the effective resistance from •To make sure power is given to each device, they are all placed in parallel Fuse A ...
How adjustable speed drives affect power distribution
How adjustable speed drives affect power distribution

CHARGE800V Operating Instructions
CHARGE800V Operating Instructions

... dividing by 1 million. If over 50 JOULES use extreme caution as improper contact can electrocute or cause serious burns ...
Harmonic Design - GE Industrial Solutions
Harmonic Design - GE Industrial Solutions

... If the soft start/motor load is large and the motor will be started often with a long ramp time, then harmonic mitigation equipment should be considered. But if the opposite is the case, and the facility’s remaining equipment is robust, then the design engineer may choose not to specify that harmoni ...
3.0A, 150kHz, Step-Down Switching Regulator LM2596
3.0A, 150kHz, Step-Down Switching Regulator LM2596

PWM Control IC with Power-Saving Function for Light
PWM Control IC with Power-Saving Function for Light

... To verify the improvement in efficiency during light load operation, this efficiency is compared to the efficiency of a conventional type IC operating in the same evaluation circuit. The conventional type IC used for the comparison is FA5311BP, and its functions are nearly equal to those of the new ...
Electrical Force - University High School
Electrical Force - University High School

... Voltages add when cells are connected ...
< 1 ... 893 894 895 896 897 898 899 900 901 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report