• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
IOSR Journal of Electrical And Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical And Electronics Engineering (IOSRJEEE)

... roles in steady-state power distribution system operation. Utilizing an already installed D-STATCOM to achieve these additional control objectives can help system operators maximize overall system performances To verify its use, a 22-kV power distribution feeder with a three-phase rectifier load was ...
Electronic Troubleshooting
Electronic Troubleshooting

... • Bridge suspected filtering Cap with a known good one of approximately the same rated value • If the ripple problems decrease – replace the capacitor ...
Extend the reach of any I C-bus system NXP I
Extend the reach of any I C-bus system NXP I

... Driving low impedance buses with large capacitance (to at least 3000pF) or driving long cables. ...
Power and Temperature
Power and Temperature

... Leakage Temperature Feedback Loop • Needs several iterations to converge Dynamic + Short Circuit Power Total Power Leakage Power ...
simulation results - Indico - Variable Energy Cyclotron Centre
simulation results - Indico - Variable Energy Cyclotron Centre

... the PSM technique is also discussed in [1]. The advantages of PSM technique are modular structured (consists of a number of identical low voltage switching modules), solid state design using IGBTs, very low stored energy, low ripple voltage at output stage, very fast turn on and turn off capability, ...
electrical safety - MIT OpenCourseWare
electrical safety - MIT OpenCourseWare

... MIT OpenCourseWare (http://ocw.mit.edu/), Massachusetts Institute of Technology. Downloaded on [DD Month YYYY]. ...
Pat`s Lectures
Pat`s Lectures

idtqs3306a - Integrated Device Technology
idtqs3306a - Integrated Device Technology

... FEATURES: ...
File
File

TIS Trailing Edge Dimmer 6 Channels 10 Amps
TIS Trailing Edge Dimmer 6 Channels 10 Amps

Thevenin Theorem
Thevenin Theorem

QuintPower-TECHNOLEAD
QuintPower-TECHNOLEAD

KF3517721775
KF3517721775

generic high voltage power supply for electrical propulsion
generic high voltage power supply for electrical propulsion

... voltage transformer. After rectification and filtering on the secondary side the high voltage is available at the output. Furthermore, the bridge is controlled by phase shift modulation since conventional pulse width modulation resonant topologies, which cannot be controlled over a wide range of loa ...
Grounding Transformer
Grounding Transformer

... A Grounding Transformer is used to provide a physical neutral for a power transformer with a delta connected downside. The Grounding Transformers neutral point has low impedance and is suitable for different grounding systems such as solid earthing, NER earthing (resistor) and resonance earthing (Ar ...
Transformer Rectifier Sets for Electrostatic Precipitators
Transformer Rectifier Sets for Electrostatic Precipitators

protection
protection

... input line fuses, a compact input filter and a system of 9 bidirectional switches that are arranged in a matrix, to convert a three-phase AC input voltage directly into a three-phase AC ...
parallel circuit - Okemos Public Schools
parallel circuit - Okemos Public Schools

... Different from a series circuit, the parallel circuit is completed whether all, two, or only oneligth is lit. ...
Document
Document

BM220 Series Analogue Arc/Digital Insulation Continuity Testers
BM220 Series Analogue Arc/Digital Insulation Continuity Testers

... automatically discharged. The BM220 Series of Insulation and Continuity Testers are ideal for testing transformers, motors, generators, switchgear, domestic appliances, power tools etc., as well as fixed wiring systems. All instruments meet the requirements of most International Standards including ...
POTENTIOMETER INTERNAL EXTERNAL 10V
POTENTIOMETER INTERNAL EXTERNAL 10V

... The unit is designed to meet Normalised European Safety Standards Standards for installation in equipment conforming to EN61010 and hence installation of the power supply unit into the equipment should comply with the following requirements. a. A PROTECTIVE EARTH must be provided for safety in accor ...
Series Circuits
Series Circuits

Product Selection Guide OptiMOS and StrongIRFET Combined
Product Selection Guide OptiMOS and StrongIRFET Combined

... required. However, StrongIRFET™ is recommended for 20 V to 75 V applications when best-inclass performance is not essential and cost is a more significant consideration. For best-in-class performance at voltages from 80 V to 150 V, OptiMOS™ 5 is recommended. If best-in-class is not essential and pri ...
Xantrex Inverter Specifications
Xantrex Inverter Specifications

... An isolation transformer is required if local regulations require grounding of the PV system, or if the utility voltage is not 208 VAC. Due to the low level of harmonic distortion produced by the converter, a general purpose dry type transformer is suitable for this application. The transformer must ...
Bip Transistor 160V 700mA VCE(sat);500mV max. PNP Single PCP
Bip Transistor 160V 700mA VCE(sat);500mV max. PNP Single PCP

... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
< 1 ... 882 883 884 885 886 887 888 889 890 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report