• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
5. Radial System Protection
5. Radial System Protection

Common-emitter circuit
Common-emitter circuit

... The flow/movement of electrons from negatively charged atoms to ...
TechTopics No. 55 Capacitor trip devices
TechTopics No. 55 Capacitor trip devices

Basic Electricity Homework
Basic Electricity Homework

... Essential Electricity Homework Exercise 6 1. A resistor has a voltage across it of 12 volts and a current through it of 2.5 amperes. Calculate the resistance of the resistor. 2. A voltage of 6 volts is across a resistor where the current is 0.5 amperes. What is the value of the resistor? 3. Calcula ...
The Vital Role of Utilities in Providing Transmission Grid Stability
The Vital Role of Utilities in Providing Transmission Grid Stability

... Grand Inga evacuation ...
XR250 351
XR250 351

... Continuous supervision with the circuit breaker in the open and closed positions and in compliance with the scheme requirements of BEBS S15 scheme H7. XR350 and XR351 relays also have a contact for pre-closing supervision, where a circuit breaker is prevented from being closed if trip relays have no ...
ABB string inverters - PRO-33.0-TL, 33 kW
ABB string inverters - PRO-33.0-TL, 33 kW

Model 348 Universal Voltage Regulator
Model 348 Universal Voltage Regulator

... The Model 348 Universal Regulator is a fully encapsulated and repairable module suitable for OEM applications as well as an economical replacement for many hard to get or obsolete regulators found on older generator sets. It is easy to install, does not require field flash* and works with all 240V s ...
Title: Design Considerations for High Step
Title: Design Considerations for High Step

The impedance transformation circle along a transmission line
The impedance transformation circle along a transmission line

3 PC power supplies - Mid-East Career and Technology Centers
3 PC power supplies - Mid-East Career and Technology Centers

... 1. The power supply converts the ______________ current line from your home to the _______________ current needed by the personal computer. ...
(EVs) on single-phase three-wire distribution feeders
(EVs) on single-phase three-wire distribution feeders

LCA717 - IXYS Power
LCA717 - IXYS Power

... • Surface Mount, Tape & Reel Version Available ...
Transmission lines
Transmission lines

... A two conductor wire system with the wires in close proximity, providing relative impedance, velocity and closed current return path to the source. Characteristic impedance is the ratio of the voltage and current waves at any one position on the transmission ...
Transmission lines
Transmission lines

Piezotron® Coupler
Piezotron® Coupler

... High-pass filtering, panel selectable Monitor the condition of the sensors and cables Exclusive "Rapid Zero" feature AC, DC or battery powered Conforming to ä ...
Chapter 1.5.2 - Digilent Learn site
Chapter 1.5.2 - Digilent Learn site

... The process of measuring a physical parameter will almost invariably change the parameter being measured. This effect is both undesirable and, in general, unavoidable. One goal of any measurement is to affect the parameter being measured as little as possible. The above statement is true of voltage ...
Withstand Voltage and Insulation Tester Model 8525
Withstand Voltage and Insulation Tester Model 8525

Total Harmonic Distortion and Effects in Electrical Power Systems
Total Harmonic Distortion and Effects in Electrical Power Systems

... operation.”1 This has been especially true after the second half of the 20th century when new types of electronic power sources caused distortion in waveforms of the power system. Power sources act as non-linear loads, drawing a distorted waveform that contains harmonics. These harmonics can cause p ...
PDF document
PDF document

... Although we used the word "switch," in fact transistors are used, which turn on and off in response to a control signal and supply the necessary current to the motor drive. With current passing through transistors, it is necessary to take transistor power loss into account. Bipolar transistors are u ...
PDF File
PDF File

... muscle forces. A good reference for numerous types of orofacial load transducers can be found in Furlan et al. (2012) and also in Furlan et al. (2010). In the same line of Kenedi et al. (2005) and Souza et al. (2004) that have proposed reconditioning of an existent testing machine and an especial el ...
3.4 Three-phase transformer (pole-mounted
3.4 Three-phase transformer (pole-mounted

...  If the LV conductors are energised from an interconnected transformer, conduct the phase-out test at the new transformer’s LV disconnector or fuse box.  If the LV conductors are not energised, proceed to item 5 (ENERGISATION OF THE NETWORK WITH LOAD) and conduct the phase-out test on normally ope ...
Electrical Insulation in Power Apparatus and Systems - Web
Electrical Insulation in Power Apparatus and Systems - Web

... and Systems - Web course COURSE OUTLINE Power transmission at high voltages has acquired considerable prominance in the recent times. To enhance the reliability of the power system network, it has become essential to design and develop a compact, cost effective and reliable insulation system. Differ ...
12v battery charger - Kaushik Science Projects
12v battery charger - Kaushik Science Projects

... used as C1.To monitor the charging status, Ampere meter is provided in the positive rail. LED act as the Charger on status. When the output is connected to the battery terminals, the meter shows a higher reading depending on the current flow into the battery. As the battery attains full charge, its ...
Electrical Check Machine (ECM) of the defrosting circuit
Electrical Check Machine (ECM) of the defrosting circuit

< 1 ... 879 880 881 882 883 884 885 886 887 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report