• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Switches - WordPress.com
Switches - WordPress.com

... The selector switch shown above switches a common contact lever to one of five different positions, to contact wires numbered 1 through 5. The most common configuration of a multi-position switch like this is one where the contact with one position is broken before the contact with the next positio ...
3-Phase AC Induction Vector Control Drive with Single Shunt
3-Phase AC Induction Vector Control Drive with Single Shunt

... construction is extremely optimized, since they have been produced for years. They are very simple and manufacturing costs are favorable. They have no brushes and require minimum maintenance. The robustness of the motor is another strong advantage. We would find induction motors mostly in applicatio ...
S260-60-3
S260-60-3

... operating this switch, carefully read and understand the contents of this manual. Refer to Service Information S165-275-1 Use and Operations Manual for the iDC Sectionalizer/Switch Control for additional information regarding the iDC switch control. ...
SUGGESTED SPECIFICATION for ASCO 7000 Series Soft Load
SUGGESTED SPECIFICATION for ASCO 7000 Series Soft Load

... Power Transfer Switch A. The power transfer switch shall be electrically operated and mechanically held. The electrical operator shall be a momentarily energized, solenoid mechanism. Main operators that include over-current disconnect devices; linear motors or gears shall not be acceptable. B. All t ...
TM 11–6625–2781–14–6
TM 11–6625–2781–14–6

... 1-16. Adjustment or repair of the opened instrument with the ac power connected should be avoided as much as possible and, when inevitable, should be performed only by a skilled person who knows the hazard involved. 1-17. Make sure only fuses of the required current rating and type (normal blow, tim ...
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module
Liebert Series 610 UPS Installation Manual - 1000kVA, 60Hz, Three Phase Single-Module

... Under typical operation and with all UPS doors closed, only normal safety precautions are necessary. The area around the UPS system should be kept free of puddles of water, excess moisture and debris. Special safety precautions are required for procedures involving handling, installation and mainten ...
Pdf - Text of NPTEL IIT Video Lectures
Pdf - Text of NPTEL IIT Video Lectures

... resistors are used. One is where the value is to be changed during for example, the operation. General example is the volume control in the case of an ordinary radio receiver. The volume control is basically a variable resistor and when you move it or turn it around you would find the volume will in ...
MSc DC/DC Converter Product Overview
MSc DC/DC Converter Product Overview

... Enough free space shall be left around the MSc DC/DC Converter to ensure sufficient air circulation, cooling as well as maintenance. You will find the required dimensions for free space in the picture and table below. If an MSc DC/DC Converter system consists of more than one MSc DC/DC Converter uni ...
18-Pulse, Air-Cooled - Rockwell Automation
18-Pulse, Air-Cooled - Rockwell Automation

PowerFlex 7000 Medium Voltage AC Drive, 18-Pulse Air
PowerFlex 7000 Medium Voltage AC Drive, 18-Pulse Air

... C. The VFD shall have a power rating that matches the driven load as shown on the electrical drawings. The VFD supplier shall coordinate with the motor manufacturer and the manufacturer of the driven equipment to ensure the VFD is sized to run at the full load rating of the equipment without overloa ...
BR34E02FVT-3
BR34E02FVT-3

... and acknowledge is always required after each byte. I C BUS data communication with several devices is possible by connecting with 2 communication lines: serial data (SDA) and serial clock (SCL). Among the devices, there should be a “master” that generates clock and control communication start and e ...
Kollmorgen S400 Servo Drive Manual
Kollmorgen S400 Servo Drive Manual

... About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Notes for the printed edition (paper version) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Hints for the online ...
Requirements for Complex Revenue Metering
Requirements for Complex Revenue Metering

... The Customer/Power Generator, its employees or agents must recognize that they are, at all times, solely responsible for the plant design, construction and operation. Neither BC Hydro nor any of their employees or agents shall be nor become the agents of the Customer/Power Generator in any manner ho ...
MAX13050/MAX13052/ MAX13053/MAX13054 Industry-Standard High-Speed CAN Transceivers with ±80V Fault Protection
MAX13050/MAX13052/ MAX13053/MAX13054 Industry-Standard High-Speed CAN Transceivers with ±80V Fault Protection

... The MAX13050/MAX13052/MAX13053/MAX13054 are pinfor-pin compatible, industry-standard, high-speed, control area network (CAN) transceivers with extended ±80V fault protection. These products are ideal industrial network applications where overvoltage protection is required. These CAN transceivers pro ...
DRT Series
DRT Series

... The environment-resistive terminals are rated IP67, so they can be used in severe environments and subjected to direct oil and water spray without a protective enclosure. Because a enclosure is not needed space is saved and installation and wiring time is reduced. ...
FTS-300 - BiddleMegger.com
FTS-300 - BiddleMegger.com

... and black terminals. Three voltages (48, 125, and 250 V) are available, depending on the input voltage required by the relay under test. The ON/RESET Indicator is an orange LED which illuminates whenever voltage is present at the D.C. outputs. The supply is overload and short-circuit protected by an ...
RevG_158_Attach
RevG_158_Attach

ZXT2MA Features and Benefits Mechanical Data
ZXT2MA Features and Benefits Mechanical Data

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
AUTOMOTIVE ELECTRICAL CIRCUITS AND WIRING
AUTOMOTIVE ELECTRICAL CIRCUITS AND WIRING

... COLD-CRANKING RATING.- The cold-cranking rating determines how much current in amperes the battery can deliver for thirty seconds at 0° F while maintaining terminal voltage of 7.2 volts or 1.2 volts per cell. This rating indicates the ability of the battery to crank a specific engine (based on start ...
andhra pradesh
andhra pradesh

Circuit Design for Realization of a 16 bit 1MS/s Successive
Circuit Design for Realization of a 16 bit 1MS/s Successive

... and helped me realize that failure is indeed a learning process. I would also like to thank my friends and lab mates. Chris David, for helping with the digital aspect of this project, and for always being willing to help me work through problems I encountered in my own design. Hattie Spetla, for alw ...
- LJMU Research Online
- LJMU Research Online

... Obrad Dordevic is with School of Engineering, Liverpool John Moores ...
General Description Features
General Description Features

... The MAX8809A/MAX8810A synchronous, 2-/3-/4phase, step-down, current-mode controllers with integrated dual-phase MOSFET drivers provide flexible solutions that fully comply with Intel® VRD11/VRD10 and AMD K8 Rev F CPU core supplies. The flexible design supplies load currents up to 150A for low-voltag ...
Electrical Components
Electrical Components

Laser PCB Milling Machine - Department of Electrical Engineering
Laser PCB Milling Machine - Department of Electrical Engineering

... group are ARC members, and are tasked with keeping the machine repaired and running, we have found this to be an increasingly difficult task. In just the last year we have had to replace the lead screw, and are currently in the process of replacing the main spindle motor. These problems resulted fro ...
< 1 ... 57 58 59 60 61 62 63 64 65 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report