Liebert Distribution Monitoring (LDM)
... Power Supply Assembly (with EMI Filter) The power supply assembly is 120-240VAC (range +6, -13%) 50/60 Hz input, 24VDC output to provide logic level power for the BCB. ...
... Power Supply Assembly (with EMI Filter) The power supply assembly is 120-240VAC (range +6, -13%) 50/60 Hz input, 24VDC output to provide logic level power for the BCB. ...
S230-30-4
... structures (Figure 6) or directly to the foundation. The stacking of the fuseless capacitor blocks may require base and/or stacking insulators. Base insulators isolate the blocks from the platform, elevating structure or foundation. Stacking insulators are used to provide electrical insulation betwe ...
... structures (Figure 6) or directly to the foundation. The stacking of the fuseless capacitor blocks may require base and/or stacking insulators. Base insulators isolate the blocks from the platform, elevating structure or foundation. Stacking insulators are used to provide electrical insulation betwe ...
ZXTP2012Z Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
ADM698 数据手册DataSheet 下载
... typ). RESET remains low for a minimum of 140 ms after VCC returns to 5 V. RESET also goes low for a minimum of 140 ms if the watchdog timer is enabled but not serviced within its timeout period. Watchdog Input. WDI is a three level input. If WDI remains either high or low for longer than the watchdo ...
... typ). RESET remains low for a minimum of 140 ms after VCC returns to 5 V. RESET also goes low for a minimum of 140 ms if the watchdog timer is enabled but not serviced within its timeout period. Watchdog Input. WDI is a three level input. If WDI remains either high or low for longer than the watchdo ...
S225-10-4C
... switch can be used in each phase to perform the bypassing and disconnecting operations in sequence. Each of these switches replaces one bypass and two disconnect switches shown in the diagrams. Mounting A regulator can be mounted on a pole, crossarm plafform, or elevating structure (optional). Regul ...
... switch can be used in each phase to perform the bypassing and disconnecting operations in sequence. Each of these switches replaces one bypass and two disconnect switches shown in the diagrams. Mounting A regulator can be mounted on a pole, crossarm plafform, or elevating structure (optional). Regul ...
WP132001EN/ Old W240-11018
... package. Protection methods exist for both overhead and pad-mounted transformers, in both 1-phase and 3-phase applications. There are many variables that need to be considered to properly define a fusing package. The fusing must withstand steady-state and overload currents, normal inrush currents, a ...
... package. Protection methods exist for both overhead and pad-mounted transformers, in both 1-phase and 3-phase applications. There are many variables that need to be considered to properly define a fusing package. The fusing must withstand steady-state and overload currents, normal inrush currents, a ...
power cApAciTors
... and can be used under the most rugged conditions. Vishay ESTA power capacitors address a wide range of energygeneration applications. Their “green” applications include energy generation in on- and off-shore wind turbines and solar power plants. Vishay ESTA power capacitors are used in energy transm ...
... and can be used under the most rugged conditions. Vishay ESTA power capacitors address a wide range of energygeneration applications. Their “green” applications include energy generation in on- and off-shore wind turbines and solar power plants. Vishay ESTA power capacitors are used in energy transm ...
Conext Core XC Series Grid Tie Photovoltaic Inverter: Operation
... Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to i ...
... Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to i ...
ups glups - Powerstar Inc
... button. If voltage is at fringes of transfer spectrum (i.e., for domestic UPSes, the defaults are at approximately 90V or 132V) the UPS is in its hysteresis band and is waiting for the input voltage to move away from these transfer points before coming back on-line. If the power quality is poor due ...
... button. If voltage is at fringes of transfer spectrum (i.e., for domestic UPSes, the defaults are at approximately 90V or 132V) the UPS is in its hysteresis band and is waiting for the input voltage to move away from these transfer points before coming back on-line. If the power quality is poor due ...
Aalborg Universitet Deng, Fujin
... Wind power is growing rapidly around the world, and the offshore wind farm is currently seen as a promising solution to satisfy the growing demand for renewable energy source. Along with the increase in the capacity of offshore wind farms and the distance between offshore wind farms and land, the hi ...
... Wind power is growing rapidly around the world, and the offshore wind farm is currently seen as a promising solution to satisfy the growing demand for renewable energy source. Along with the increase in the capacity of offshore wind farms and the distance between offshore wind farms and land, the hi ...
TEC-05X Manual - NPI Electronic
... Disconnect mains power-plug when replacing the fuse or changing line voltage. Replace fuse only by appropriate specified type. STATIC ELECTRICITY: Electronic equipment is sensitive to static discharges. Some input devices such as headstages are equipped with very sensitive FET amplifiers, which can ...
... Disconnect mains power-plug when replacing the fuse or changing line voltage. Replace fuse only by appropriate specified type. STATIC ELECTRICITY: Electronic equipment is sensitive to static discharges. Some input devices such as headstages are equipped with very sensitive FET amplifiers, which can ...
MAX4855 0.75 Integrated Comparators , Dual SPDT Audio Switch with
... low on-resistance (0.75Ω) with a +3V supply making it ideal for audio switching applications in portable devices. The device also integrates two internal comparators that can be used for headphone detection or mute/send key functions. The MAX4855 is available in the space-saving (3mm x 3mm), 16-pin ...
... low on-resistance (0.75Ω) with a +3V supply making it ideal for audio switching applications in portable devices. The device also integrates two internal comparators that can be used for headphone detection or mute/send key functions. The MAX4855 is available in the space-saving (3mm x 3mm), 16-pin ...
AN-6047 FIN324C Reset and Standby Summary www.fairchildsemi.com
... deserializer have the reset pin. When reset is in LOW state, the device is in a power-down mode. The power-down mode consumes less than 10µA of power. When reset is asserted HIGH, all registers and outputs are reset to initial states. The reset is designed with an input filter, which delays the inte ...
... deserializer have the reset pin. When reset is in LOW state, the device is in a power-down mode. The power-down mode consumes less than 10µA of power. When reset is asserted HIGH, all registers and outputs are reset to initial states. The reset is designed with an input filter, which delays the inte ...
(Selective).
... • Definition of Emergency System per NEC 700.1: Emergency Systems are those systems legally required and classed as emergency by municipal, state, federal, or other codes, or by ...
... • Definition of Emergency System per NEC 700.1: Emergency Systems are those systems legally required and classed as emergency by municipal, state, federal, or other codes, or by ...
Definition and Classification of Power System Stability IEEE/CIGRE
... Power systems are subjected to a wide range of disturbances, small and large. Small disturbances in the form of load changes occur continually; the system must be able to adjust to the changing conditions and operate satisfactorily. It must also be able to survive numerous disturbances of a severe n ...
... Power systems are subjected to a wide range of disturbances, small and large. Small disturbances in the form of load changes occur continually; the system must be able to adjust to the changing conditions and operate satisfactorily. It must also be able to survive numerous disturbances of a severe n ...
a 3 in Chip Scale Package ADG758/ADG759
... device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Only one absolute maximum rating may be applied at any one time. ...
... device at these or any other conditions above those listed in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Only one absolute maximum rating may be applied at any one time. ...
ZXLD1366 Description Pin Assignments
... The ZXLD1366 is a continuous mode inductive step-down converter, designed for driving single or multiple series connected LEDs efficiently from a voltage source higher than the LED voltage. The device operates from an input supply between 6V and 60V and provides an externally adjustable output curre ...
... The ZXLD1366 is a continuous mode inductive step-down converter, designed for driving single or multiple series connected LEDs efficiently from a voltage source higher than the LED voltage. The device operates from an input supply between 6V and 60V and provides an externally adjustable output curre ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.