Evaluates: MAX8808X/MAX8808Y/MAX8808Z MAX8808 Evaluation Kit General Description Features
... fast-charge current. Once the cell voltage has passed 2.5V, the charger soft-starts as it enters the fast-charge stage. The MAX8808Y and MAX8808Z do not have the prequalification stage, and therefore, soft-start to the fast-charge level immediately when enabled. The fastcharge current level is progr ...
... fast-charge current. Once the cell voltage has passed 2.5V, the charger soft-starts as it enters the fast-charge stage. The MAX8808Y and MAX8808Z do not have the prequalification stage, and therefore, soft-start to the fast-charge level immediately when enabled. The fastcharge current level is progr ...
A Direct Voltage Unbalance Compensation Strategy for
... wind turbines, photovoltaic systems and micro-turbines, have gain a great increasing interest since they are economic and environment friendly. In general, power electronic converters are used as interfaces between DERs and the grid [1], such that electrical power with good quality and high reliabil ...
... wind turbines, photovoltaic systems and micro-turbines, have gain a great increasing interest since they are economic and environment friendly. In general, power electronic converters are used as interfaces between DERs and the grid [1], such that electrical power with good quality and high reliabil ...
MAAVSS0007 Voltage Variable Absorptive Attenuator 40 dB, 0.5 - 3.0 GHz
... Single Positive Voltage Control: 0 to +5 Volts 40 dB Attenuation Range at 900 MHz ± 2 dB Linearity from BSL Low DC Power Consumption Tape and Reel Packaging Available Lead-Free SOIC-8 Package 100% Matte Tin Plating over Copper Halogen-Free “Green” Mold Compound 260°C Reflow Compatible RoHS* Complian ...
... Single Positive Voltage Control: 0 to +5 Volts 40 dB Attenuation Range at 900 MHz ± 2 dB Linearity from BSL Low DC Power Consumption Tape and Reel Packaging Available Lead-Free SOIC-8 Package 100% Matte Tin Plating over Copper Halogen-Free “Green” Mold Compound 260°C Reflow Compatible RoHS* Complian ...
intelligent - SOSManuals
... same type and rating. CAUTION: If the reverse battery protection fuses are blown during installation, check to see that the battery has been connected properly before replacing the fuses. Replace the fuses only with the same type and rating as the original fuses. Using other fuses could result in th ...
... same type and rating. CAUTION: If the reverse battery protection fuses are blown during installation, check to see that the battery has been connected properly before replacing the fuses. Replace the fuses only with the same type and rating as the original fuses. Using other fuses could result in th ...
V-Guard | Buying Guide for Voltage Stabilizers
... appliances like television, refrigerator, air conditioner etc. and affect your valuable equipment critically, even leaving them in to a permanently damaged condition. A carefully selected, right kind of stabilizer can get you out of this problem. It prevents undesirable voltage fluctuations to enter ...
... appliances like television, refrigerator, air conditioner etc. and affect your valuable equipment critically, even leaving them in to a permanently damaged condition. A carefully selected, right kind of stabilizer can get you out of this problem. It prevents undesirable voltage fluctuations to enter ...
2SC3838K
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
... Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no respo ...
LNK362-364 rev_E.indd
... 4. For designs where PO > 2.5 W Clampless designs are not practical and an external RCD or Zener clamp should be used. 5. Ensure that worst-case high line, peak drain voltage is below the BVDSS specification of the internal MOSFET and ideally ≤ 650 V to allow margin for design variation. †For 110 VA ...
... 4. For designs where PO > 2.5 W Clampless designs are not practical and an external RCD or Zener clamp should be used. 5. Ensure that worst-case high line, peak drain voltage is below the BVDSS specification of the internal MOSFET and ideally ≤ 650 V to allow margin for design variation. †For 110 VA ...
MAX798 High-Accuracy Step-Down Controller with Synchronous Rectifier for CPU Power _______________General Description
... The MAX798 is designed to deliver a more accurate output voltage than the MAX797. A major source of the MAX797’s output error is the decrease in output voltage with increasing load. This error is greatly reduced in the MAX798 by increasing the gain of the voltage-sense signal relative to the current ...
... The MAX798 is designed to deliver a more accurate output voltage than the MAX797. A major source of the MAX797’s output error is the decrease in output voltage with increasing load. This error is greatly reduced in the MAX798 by increasing the gain of the voltage-sense signal relative to the current ...
Dual Schottky Barrier Diode, 30 V, 3 A
... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
... rise to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redu ...
MAX1623 3A, Low-Voltage, Step-Down Regulator with Synchronous Rectification and Internal Switches General Description
... The MAX1623 switch-mode buck regulator with synchronous rectification provides local CPU and bus-termination power in notebook and desktop computers. An internal 55mΩ (typ), 3A PMOS power switch and 60mΩ (typ), 3A NMOS synchronous-rectifier switch deliver continuous load currents up to 3A from a 5V ...
... The MAX1623 switch-mode buck regulator with synchronous rectification provides local CPU and bus-termination power in notebook and desktop computers. An internal 55mΩ (typ), 3A PMOS power switch and 60mΩ (typ), 3A NMOS synchronous-rectifier switch deliver continuous load currents up to 3A from a 5V ...
Low drop fixed and adjustable positive voltage
... • Available in ± 2% (at 25 °C) and 4% in full temperature range • High supply voltage rejection: – 80 dB typ. (at 25 °C) • Temperature range: 0 °C to 125 °C ...
... • Available in ± 2% (at 25 °C) and 4% in full temperature range • High supply voltage rejection: – 80 dB typ. (at 25 °C) • Temperature range: 0 °C to 125 °C ...
2 DIODE CLIPPING and CLAMPING CIRCUITS
... voltage, technically called “threshold voltage” and can be changed to a desired value by inserting a D.C. voltage source. This is achieved in two different ways. In the first type, the voltage source of Em ( positive or negative) is connected through output terminals as in Fig. 2.4. Depending on the ...
... voltage, technically called “threshold voltage” and can be changed to a desired value by inserting a D.C. voltage source. This is achieved in two different ways. In the first type, the voltage source of Em ( positive or negative) is connected through output terminals as in Fig. 2.4. Depending on the ...
DRP024V060W1AZ Datasheet
... To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air te ...
... To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air te ...
Element 4: Electrical Hazards and Control
... sensation is felt by the person receiving the shock. • Between 2 and 10 mA current starts to flow through the body and stimulates muscles to contract. This can be felt, it causes muscles to tremble and it may hurt. But the person receiving the shock is able to control their muscles and can let go o ...
... sensation is felt by the person receiving the shock. • Between 2 and 10 mA current starts to flow through the body and stimulates muscles to contract. This can be felt, it causes muscles to tremble and it may hurt. But the person receiving the shock is able to control their muscles and can let go o ...
5.6 A 0.68nW/kHz Supply-Independent Relaxation Oscillator with
... highlighted by inset waveforms. The 0.9V curve crosses the BY3 trip point at the correct time but experiences a delayed trigger. Likewise, an early trigger at 1.5V results in shorter TP. To reduce this effect, X1 must be designed to have sufficient bandwidth at VDDmin which costs power [4]. However, ...
... highlighted by inset waveforms. The 0.9V curve crosses the BY3 trip point at the correct time but experiences a delayed trigger. Likewise, an early trigger at 1.5V results in shorter TP. To reduce this effect, X1 must be designed to have sufficient bandwidth at VDDmin which costs power [4]. However, ...
Partial-Resonant Buck–Boost and Flyback DC–DC Converters
... nonlinear and unbalanced loads, has aggravated the powerquality (PQ) problems in the power distribution net-work. They cause excessive neutral currents, overheating of electrical apparatus, poor power factor, voltage distortion, high levels of neutral-to-ground voltage, and interference with communi ...
... nonlinear and unbalanced loads, has aggravated the powerquality (PQ) problems in the power distribution net-work. They cause excessive neutral currents, overheating of electrical apparatus, poor power factor, voltage distortion, high levels of neutral-to-ground voltage, and interference with communi ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.