ASIC 2001: FORMATTING AND SUBMITTING YOUR PAPER
... integrate analog circuits with high-end specifications due to process variations, these analog circuits are usually made as separate components such as ceramic filters. In contrast, with the proposed method, it is possible to integrate these analog circuits on a single LSI, resulting in cost reducti ...
... integrate analog circuits with high-end specifications due to process variations, these analog circuits are usually made as separate components such as ceramic filters. In contrast, with the proposed method, it is possible to integrate these analog circuits on a single LSI, resulting in cost reducti ...
mirror inflector
... mirror inflector located at the centre of the cyclotron and comes out horizontally in the median plane of the cyclotron for further acceleration by dee voltage. We choose non-scaling mode of operation as dee voltage is kept near its maximum and the beam orbits trajectory do not have a constant patte ...
... mirror inflector located at the centre of the cyclotron and comes out horizontally in the median plane of the cyclotron for further acceleration by dee voltage. We choose non-scaling mode of operation as dee voltage is kept near its maximum and the beam orbits trajectory do not have a constant patte ...
Relaying Short Lines - GE Grid Solutions Online Store
... fault resistance that can be very large depending on the components involved in the fault. For example, a tree fault, or a fault to ground through a fire can have a very large resistive component relative to the arc resistance. The effect of infeed on this component is to magnify the resistance as w ...
... fault resistance that can be very large depending on the components involved in the fault. For example, a tree fault, or a fault to ground through a fire can have a very large resistive component relative to the arc resistance. The effect of infeed on this component is to magnify the resistance as w ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
... communications between all three (3) terminals is required. (2) Notwithstanding subsections 6(c) and 24(1), if a protection study is undertaken identifying the level of mis-coordination and associated risks, the ISO may choose to grant an exemption in the functional ...
... communications between all three (3) terminals is required. (2) Notwithstanding subsections 6(c) and 24(1), if a protection study is undertaken identifying the level of mis-coordination and associated risks, the ISO may choose to grant an exemption in the functional ...
Design overhead distribution systems
... possibly reinforced with steel strands. Copper was sometimes used for overhead transmission but aluminium is lower in weight for equivalent performance, and much lower in cost. Overhead conductors are a commodity supplied by several companies worldwide. Improved conductor material and shapes are reg ...
... possibly reinforced with steel strands. Copper was sometimes used for overhead transmission but aluminium is lower in weight for equivalent performance, and much lower in cost. Overhead conductors are a commodity supplied by several companies worldwide. Improved conductor material and shapes are reg ...
The Common Source JFET Amplifier - IDC
... Note that this equation only determines the ratio of the resistors R1 and R2, but in order to take advantage of the very high input impedance of the JFET as well as reducing the power dissipation within the circuit, we need to make these resistor values as high as possible, with values in the order ...
... Note that this equation only determines the ratio of the resistors R1 and R2, but in order to take advantage of the very high input impedance of the JFET as well as reducing the power dissipation within the circuit, we need to make these resistor values as high as possible, with values in the order ...
SEL-734 Data Sheet
... adds to meter accuracy when the meter location and billing points differ. ACSELERATOR QuickSet Software provides a simple test mode interface to easily verify meter accuracy. Communications and I/O Select from seven communications ports and eight communications protocols, including 10/100BASE-T or 1 ...
... adds to meter accuracy when the meter location and billing points differ. ACSELERATOR QuickSet Software provides a simple test mode interface to easily verify meter accuracy. Communications and I/O Select from seven communications ports and eight communications protocols, including 10/100BASE-T or 1 ...
... to the impact on sensitive industrial loads and costs led by the damages and maintenance costs, voltage sags have focused the attention of power quality studies leaded by the utilities. Unfortunately, those disturbances propagate through the power system affecting loads connected in whole network. H ...
A. Eddy current losses - Electrical and Computer Engineering
... ERRORESONANCE is a nonlinear phenomenon occurring in electrical circuits involving at least one or several saturable reactors, capacitances and a power supply. Often, the saturable reactors are inductive potential transformers. This phenomenon is characterized by the possible existence of several st ...
... ERRORESONANCE is a nonlinear phenomenon occurring in electrical circuits involving at least one or several saturable reactors, capacitances and a power supply. Often, the saturable reactors are inductive potential transformers. This phenomenon is characterized by the possible existence of several st ...
Mapping Document
... meeting all of the requirements of R7.1, R7.2, R7.3, and R7.4 recorded no further than two Substations away, then for each Substation having a total of seven or more transmission lines connected at 200 kV or above, the Transmission Owner shall record (or have a process in place to derive) the follow ...
... meeting all of the requirements of R7.1, R7.2, R7.3, and R7.4 recorded no further than two Substations away, then for each Substation having a total of seven or more transmission lines connected at 200 kV or above, the Transmission Owner shall record (or have a process in place to derive) the follow ...
THE CURRENT STATUS OF POWER SEMICONDUCTORS Jan
... SiC MOSFETs are typically available from breakdown voltage of 900 V. Their specific on-state resistance RON_SP is claimed to approach the theoretical value for the SiC 1-D unipolar device starting from the breakdown voltages of 3.3 kV [6]. For 900 V voltage class they outperform the best in class si ...
... SiC MOSFETs are typically available from breakdown voltage of 900 V. Their specific on-state resistance RON_SP is claimed to approach the theoretical value for the SiC 1-D unipolar device starting from the breakdown voltages of 3.3 kV [6]. For 900 V voltage class they outperform the best in class si ...
Basic Electronics to Test Fixtures
... If we take one winding of wire, and wind a second winding around it, the magnetic field produced by one winding will induce a voltage in the second winding. The voltage induced in the second winding will depend on the ratio of windings. If the first winding, we'll call it the primary, has the same n ...
... If we take one winding of wire, and wind a second winding around it, the magnetic field produced by one winding will induce a voltage in the second winding. The voltage induced in the second winding will depend on the ratio of windings. If the first winding, we'll call it the primary, has the same n ...
Switched-Mode Parallel-Circuit Class E Tuned Power Amplifiers
... The switched-mode Class E tuned power amplifiers with a shunt capacitance have found widespread application due to their design simplicity and high efficiency operation [1]. Such a circuit configuration consists of the shunt capacitance, series inductance, RF choke to provide the connection to the D ...
... The switched-mode Class E tuned power amplifiers with a shunt capacitance have found widespread application due to their design simplicity and high efficiency operation [1]. Such a circuit configuration consists of the shunt capacitance, series inductance, RF choke to provide the connection to the D ...
BDTIC www.BDTIC.com/infineon Phase Cut Dimmable Isolated Flyback Converter for LED Retrofit Bulb with
... shaped to be more or less sinusoidal and thus high power factor is achieved, with input current harmonics fulfilling the requirements of EN 61000-3-2 standard. ...
... shaped to be more or less sinusoidal and thus high power factor is achieved, with input current harmonics fulfilling the requirements of EN 61000-3-2 standard. ...
Vector Network Analyzer (VNA)
... An ideal antenna solution has an impedance of 50 ohm all the way from the transceiver to the antenna, to get the best possible impedance match between transceiver, transmission line and antenna. Since ideal conditions do not exist in reality, the impedance in the antenna interface often must be comp ...
... An ideal antenna solution has an impedance of 50 ohm all the way from the transceiver to the antenna, to get the best possible impedance match between transceiver, transmission line and antenna. Since ideal conditions do not exist in reality, the impedance in the antenna interface often must be comp ...
LVD-12-30 Low Voltage Disconnect
... Back-up batteries at communication sites may be damaged by over-discharge when AC power is lost for extended periods. Unless power is restored in a timely fashion, transceivers will continue to draw current from the batteries long after any usable voltage has been drained from them. In some cases, c ...
... Back-up batteries at communication sites may be damaged by over-discharge when AC power is lost for extended periods. Unless power is restored in a timely fashion, transceivers will continue to draw current from the batteries long after any usable voltage has been drained from them. In some cases, c ...
Load, Switch, and Commutation Considerations
... where toff is the turn-off period as shown in figure 6.4. The average power loss due to switching, which is required for the thermal design outlined in chapter 5, is obtained by multiplying energy loss W by the switching frequency fs. That is, the turn-on switching loss is given by Pon = I mVs t o ...
... where toff is the turn-off period as shown in figure 6.4. The average power loss due to switching, which is required for the thermal design outlined in chapter 5, is obtained by multiplying energy loss W by the switching frequency fs. That is, the turn-on switching loss is given by Pon = I mVs t o ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.