• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NTB75N03R, NTP75N03R Power MOSFET 75 Amps, 25 Volts N
NTB75N03R, NTP75N03R Power MOSFET 75 Amps, 25 Volts N

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
UNIT I _II
UNIT I _II

Slide 1
Slide 1

... When a TV panel goes beyond 32 inches, the CCFL (cold cathode fluorescent) backlighting is driven directly from the 400VDC. Another example of the demand for higher voltages and energy efficiency. The larger the panel the more voltage required and energy consumed!!! ...
Small Current Output Power Management Switch ICs
Small Current Output Power Management Switch ICs

... zCautions on use (1) Absolute Maximum Ratings An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down devices, thus making impossible to identify breaking mode such as a short circuit or an open circuit. If any special mode ...
ZIKA OWNER`S MANUAL  I-200c Premium/ I-250c
ZIKA OWNER`S MANUAL I-200c Premium/ I-250c

ARCCOM Installation and Operation Manual
ARCCOM Installation and Operation Manual

... The ARCCOM must use copper source circuit conductors only. For the PV output circuit feeders, either copper or aluminum conductors may be used, although due to terminal size restrictions, aluminum wiring may not be an option in all cases. As with any aluminum wiring, follow best industry practices t ...
Automatic Power Factor Correction by Continuous Monitoring
Automatic Power Factor Correction by Continuous Monitoring

... available in department. I would also like to thanks to my guide Mr. U.E Hiwase For his useful guidance and for helping me to carrying out my project successfully. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Aalborg Universitet after disconnection
Aalborg Universitet after disconnection

IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org

... conditions. All users, STUs and CTU shall provide systems to telemeter power system parameter such as flow, voltage and status of switches/transformer taps etc. in line with interface requirements and other guideline made available by RLDC. The associated communication system to facilitate data flow ...
EUP3510 Preliminary  Current Limited Load Switch
EUP3510 Preliminary Current Limited Load Switch

... The EUP3510 is a Current Limited P-channel MOSFET power switch designed for high-side load-switching applications. An integrated current-limiting circuit protects the input supply against large currents which may cause the supply to fall out of regulation. It can be used to control loads that requir ...
Process Variation Aware Synthesis of Application-Specific MPSoCs to Maximize Yield
Process Variation Aware Synthesis of Application-Specific MPSoCs to Maximize Yield

... the presence of voltage islands, efficient VI-aware voltageassignment, core-mapping and routing techniques need to be employed [7]-[9], where the number of VLCs (voltage level converters) and MCFIFO (multiple clock first in-first-out) queue based frequency level converters required for inter-VI comm ...
AMP215_Switchgear_final_130813 - International Atomic Energy
AMP215_Switchgear_final_130813 - International Atomic Energy

... for high resistance connections or abnormal heating pattern. In order to get useful results for the main circuits, connected objects have to be in operation. Airborne acoustic testing may be used in medium voltage switchgear to detect discharges. Scan all components using an airborne ultrasonic dete ...
AIremote Battery Monitor Users Guide
AIremote Battery Monitor Users Guide

... Also, note that healthy verses unhealthy batteries will also discharge differently, and that suggested estimated start times supplied above take both unhealthy and healthy batteries into consideration. ...
Z04706163168
Z04706163168

... with galvanic isolation permits one to achieve sinusoidal input-current wave shaping and output-voltage regulation simultaneously without adding any auxiliary transistors. Recently, this procedure, together with an appropriate control process, has been used to obtain low-cost high-efficiency single- ...
Frequency Foldback Current Mode PWM
Frequency Foldback Current Mode PWM

Three-Phase Brushless Motor Driver
Three-Phase Brushless Motor Driver

... Reducing the number of magnetic poles can be effective in dealing with problem. The IN1 Hall signal is used as the FG signal for speed control internally to the IC. Since noise can easily become a problem, a capacitor must be inserted across this input. However, since this could result in difference ...
Evaluates:  MAX5069A MAX5069A Evaluation Kit General Description Features
Evaluates: MAX5069A MAX5069A Evaluation Kit General Description Features

... (+VIN, -VIN). This capacitor should be rated for 100V and be able to carry approximately 2A of ripple current. Lower ripple-current-rated capacitors should be acceptable for short-term operation The push-pull converter achieves high efficiency by using two external n-channel MOSFETs on the primary s ...
applications of cathode ray tubes i
applications of cathode ray tubes i

... the time for the whole period, and then falls back to its initial value again. In the second case one of the two voltages is applied to each set of deflection plates. If for instance the two altemating voltages are sinusoidal with an integral ratio between their frequencies, so-called Lissaj ous fig ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... (CCM) or discontinuous conduction mode (DCM). The operation in CCM offers the advantage of requiring lower root mean- square (rms) currents through the power switches, which yields high efficiency. However, operation in CCM presents the disadvantage of having no relationship between the output power ...
RA03M8894M 数据资料DataSheet下载
RA03M8894M 数据资料DataSheet下载

pdfnew/aob2og01?
pdfnew/aob2og01?

... microphone on stage feeding a console input is an example of half of a four-wire circuit. It would not usually be called such, since it is not an intercom use, but it remains one-half of a communications path from the stage to the intended listeners. The reverse path, for example the console’s talk- ...
IPSERIES sm.qxd
IPSERIES sm.qxd

AD8018
AD8018

... packages. Low-distortion, rail-to-rail output voltage, and highcurrent drive in small packages make the AD8018 ideal for use in low-cost USB, PCMCIA, and PCI Customer Premise Equipment for ADSL, SDSL, VDSL, and proprietary xDSL systems. Both models will operate over the temperature range –40°C to +8 ...
Buck Converter: Negative Spike at Phase Node
Buck Converter: Negative Spike at Phase Node

... the maximum voltage across the MOSFET. This maximum voltage across the MOSFET will always be higher than Vin during the turn off event as long as a parasitic inductance L stray is present. Therefore, even in the most common case when the MOSFET is not reaching avalanche (as switching speed is slow a ...
< 1 ... 552 553 554 555 556 557 558 559 560 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report