• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SB-200 Restoration and ModificationsWA3DSP
SB-200 Restoration and ModificationsWA3DSP

... The Heath SB-200 was introduced in 1964 and sold in that year for $200. It was last produced in 1978 when the SB-201 was introduced without 10 meter capability due to the FCC laws governing the manufacture of linear amplifiers for that frequency range. The SB-201 was manufactured until 1983. The SB- ...
Data Bulletin Shedding Non-Priority Loads with
Data Bulletin Shedding Non-Priority Loads with

... The detection of a threshold triggers load shedding of the load connected to the threshold. Shedding the load connected to threshold prevents the circuit breaker from tripping and therefore improves availability. The reflex load-shedding order is sent to the load-shedding contactor through the SDx m ...
pedal power - Voodoo Lab
pedal power - Voodoo Lab

... available for guitar effects. It’s eight 9V outputs will power any type of battery operated effect. Each output is completely isolated, short-circuit protected, highly filtered and regulated. This insures reliable operation, free of hum and noise. Pedal Power 2 Plus includes two high current outputs ...
Wide Bandwidth 4X1 Video Multiplexer
Wide Bandwidth 4X1 Video Multiplexer

... The MPC100 operates from ±5V power supplies (±6V maximum). Do not attempt to operate with larger power supply voltages or permanent damage may occur. The buffer outputs are not current-limited or protected. If the output is shorted to ground, currents up to 18mA could flow. Momentary shorts to groun ...
Jeopardy
Jeopardy

Inductance - MrsCDsAPPhysics
Inductance - MrsCDsAPPhysics

... The inductance of the inductor results ina back emf, an inductor in a circuit opposes changes in the current through that circuit. If the battery voltage in the circuit increased so that the current rises, the inductor opposes this change, and the rise is not instantaneous. If the battery voltage is ...
Preventing Excess Power Consumption on
Preventing Excess Power Consumption on

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
MAX17019 Evaluation Kit Evaluates: General Description Features
MAX17019 Evaluation Kit Evaluates: General Description Features

... The MAX17019 evaluation kit (EV kit) presents the MAX17019 high input-voltage quad-output controller in a typical application setup. The EV kit operates from a 5.5V to 38V input range. The high input voltage of 38V makes this device ideal for automotive applications. High-voltage controller A is use ...
300V PT IGBT Technology
300V PT IGBT Technology

... resistance similar to MOSFETs. The relationship at any given voltage and current is simply Ohm’s law: on-state voltage equals current times on resistance. IGBT on resistance is it on-state voltage (VCE(on)) divided by collector current IC, just like MOSFET RDS(on) is drainsource on-state voltage div ...
High Accuracy Ultralow I , 300 mA, anyCAP Low Dropout Regulator
High Accuracy Ultralow I , 300 mA, anyCAP Low Dropout Regulator

... with the MAX8860, the ADP3333 operates with a wider input voltage range of 2.6 V to 12 V and delivers a load current up to 300 mA. ADP3333 stands out from other conventional LDOs with a novel architecture and an enhanced process that enables it to offer performance advantages over its competition. I ...
Document
Document

... Utility companies prefer high power factor loads. • These loads consume the least amount of capacity for the amount of billable power (active power). • Lower power factors are penalized. Charge extra for low power factor. Usually 0.85 or less. Power factor of Industrial Plants • Most industrial plan ...
MAX1920/MAX1921 Low-Voltage, 400mA Step-Down DC-DC Converters in SOT23 General Description
MAX1920/MAX1921 Low-Voltage, 400mA Step-Down DC-DC Converters in SOT23 General Description

... Figures 1 and 2 are the application circuits that utilize small ceramic output capacitors. For stability, the circuit obtains feedback from the LX node through R1, while load transients are fed-forward through CFF. Because there is no D.C. feedback from the output, the output voltage exhibits load r ...
4.0 operation - Always On UPS Systems
4.0 operation - Always On UPS Systems

... The “SHP” is designed as a TVSS (Transient Voltage Surge Suppressor) for low voltage distribution equipment of 240V or less, and is configured to connect directly to the main service entrance panel or downstream subpanels as a primary or secondary form of protection, as used in one or two stage syst ...
HP Integrity rx3600 server
HP Integrity rx3600 server

... The process of adding moisture to the air within a critical space. ...
Reference Materials - Jefferson Electric
Reference Materials - Jefferson Electric

... The transformer should be connected only as described on the nameplate or the wiring diagram inside the wiring compartment cover, or as otherwise specifically authorized. Transformers without terminal boards, usually the smaller size transformers, provide leads for connections. IMPORTANT: Any unused ...
PSU_Part1_EfficiencyPowerFactor - Renesas e
PSU_Part1_EfficiencyPowerFactor - Renesas e

... help you educate customers about Renesas products. Included in this is product information on Renesas ICs and discrete devices for power supply ...
Toronto Hydro - Electric System
Toronto Hydro - Electric System

... engineer from the commissioning tests. The design engineer retains the option of participating in the commissioning of the system. The requirements below are primarily from Appendix F.2 of the Distribution System Code‟s (“DSC”), Institute of Electrical and Electronics Engineers (“IEEE”) Standard 154 ...
LM12CL 80W Operational Amplifier 80W Operational
LM12CL 80W Operational Amplifier 80W Operational

... output terminal with short leads. Single-point grounding to avoid dc and ac ground loops is advised. The impedance, Z1, is the wire connecting the op amp output to the load capacitor. About 3-inches of number-18 wire (70 nH) gives good stability and 18-inches (400 nH) begins to degrade load-transien ...
Practical Methods for Verifying Removal of Trojan Stable Operating
Practical Methods for Verifying Removal of Trojan Stable Operating

... for even simple circuits is tedious and computation time is prohibitive if the circuit is very large. Homotopy methods are widely used to trace DC solutions though these methods do not guarantee all operating points will be identified and computation time can be large as well. Some papers also discu ...
DCX100NS  General Descriptions 100mA DUAL PRE-BIASED TRANSISTORS
DCX100NS General Descriptions 100mA DUAL PRE-BIASED TRANSISTORS

... DCX100NS is best suited for applications where the load needs to be turned on and off using control circuits like micro-controllers, comparators etc. particularly at a point of load. It features a discrete PNP pass transistor which can support continuous maximum current up to 100 mA. It also contain ...
W‑ST Wall‑mount Multi‑candela Strobes
W‑ST Wall‑mount Multi‑candela Strobes

HP 4145B Semiconductor Parameter Analyzer
HP 4145B Semiconductor Parameter Analyzer

Unit 9 PowerPoint Slides
Unit 9 PowerPoint Slides

... don’t use the voltages and currents on input or output pins.) A lower-power device wastes less energy, generates less heat, and costs less to run than a higher-power device. ...
TL081 OpAmp - U.C.C. Physics Department
TL081 OpAmp - U.C.C. Physics Department

85-W 48-V Input Dual-Complimentary Output DC/DC Converter for
85-W 48-V Input Dual-Complimentary Output DC/DC Converter for

< 1 ... 487 488 489 490 491 492 493 494 495 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report