• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Automatic Transfer Switch Controller
Automatic Transfer Switch Controller

MAX17010 Internal-Switch Boost Regulator with Integrated High-Voltage Level Shifter and Op Amp
MAX17010 Internal-Switch Boost Regulator with Integrated High-Voltage Level Shifter and Op Amp

... High-Voltage Level Shifter and Op Amp The MAX17010 contains a high-performance step-up switching regulator, a high-speed operational amplifier (op amp), and a high-voltage level-shifting scan driver. The device is optimized for thin-film transistor (TFT) liquidcrystal display (LCD) applications. The ...
Evaluates: MAX20070 MAX20070 Evaluation Kit
Evaluates: MAX20070 MAX20070 Evaluation Kit

... The EV kit is fully assembled and tested. Follow the steps below to verify board operation. Caution: Do not turn on the power supply until all connections are completed. 1) Verify that a shunt is installed on jumpers JP2, JP3, and JP5. 2) Verify that jumpers JP1 and JP4 are open. 3) Connect the p ...
FI25986990
FI25986990

direct torque control of induction motors
direct torque control of induction motors

... Estimated d and q components of stator flux during the response to a torque command alternating between 50% and 200% of the rated torque These results show that the decoupling between the stator flux components can be achieved controlling directly the magnitude of the stator flux ...
MAX4789–MAX4794 200mA/250mA/300mA Current-Limit Switches General Description Features
MAX4789–MAX4794 200mA/250mA/300mA Current-Limit Switches General Description Features

... Reverse Current Protection The MAX4789–MAX4794 limit the reverse current (VOUT to VIN) from exceeding the maximum IREV value. The switch is shut off and FLAG is asserted (MAX4789/ MAX4791/MAX4793) if the reverse current-limit condition persists for more than the blanking time. This feature prevents ...
ekonomski fakultet podgorica
ekonomski fakultet podgorica

... output power to the transformer volt-ampere rating required by the secondary winding: ...
Power Factor
Power Factor

... Phase advancers are used to improve the power factor of induction motors. The low power factor of an induction motor is due to the fact that its stator winding draws exciting current which lags be- hind the supply voltage by 90°. If the exciting ampere turns can be provided from some other a.c. sour ...
FSB50550A / FSB50550AT Motion SPM 5 Series ®
FSB50550A / FSB50550AT Motion SPM 5 Series ®

... Figure 3. Recommended MCU Interface and Bootstrap Circuit with Parameters 3rd Notes: 1. Parameters for bootstrap circuit elements are dependent on PWM algorithm. For 15 kHz of switching frequency, typical example of parameters is shown above. 2. RC-coupling (R5 and C5) and C4 at each input of Motion ...
Q2 - Department of Electronic Engineering
Q2 - Department of Electronic Engineering

... handle values other than binary, based on which some future devices could possibly mimic biological functions towards a new generation of brain-like computers. Let us hope that Leon’s baby memristor will grow fast and become commercialized soon, so that the nanoscale electronics can be further enabl ...
ACS754xCB-130 - Allegro Microsystems
ACS754xCB-130 - Allegro Microsystems

... been saturated, usually when the device has been subjected to a full-scale or high-current overload condition. The magnetic offset is largely dependent on the material used as a flux concentrator. The larger magnetic offsets are observed at the lower operating temperatures. Accuracy (ETOT). The accu ...
Electrical Safety - the Mining Quiz List
Electrical Safety - the Mining Quiz List

... 3. The equipment is an aerial lift insulated for the voltage involved, and if the work is performed by a qualified person, the clearance (between the uninsulated portion of the aerial lift and the power line) may be reduced to the distance given in 29 CFR 1910.334 S-5 Below. Voltage Range (Phase-to- ...
Aalborg Universitet Yao, Zhilei; Xu, Jing; Guerrero, Josep M.
Aalborg Universitet Yao, Zhilei; Xu, Jing; Guerrero, Josep M.

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

24V, 3.3VOUT, High Current Synchronous Buck Converter With LDO
24V, 3.3VOUT, High Current Synchronous Buck Converter With LDO

... The NB677 is a fully integrated high frequency synchronous rectified step-down switch mode converter with 3.3V fixed output voltage. It offers very compact solution to achieve 8A continuous output current and 10A peak output current over a wide input supply range with excellent load and line regulat ...
HMC855LC5
HMC855LC5

... the data into other devices. The demux is DC coupled supporting broadband operation. All clock and data inputs to the HMC855LC5 are CML and terminated on-chip with 50 Ohms to the positive supply, GND, and may be DC or AC coupled. The differential outputs are source terminated to 50 Ohms and may also ...
REF3033-Q1 数据资料 dataSheet 下载
REF3033-Q1 数据资料 dataSheet 下载

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
FEATURES GENERAL DESCRIPTION The ADP197CB-EVALZ is used to demonstrate the functio- e
FEATURES GENERAL DESCRIPTION The ADP197CB-EVALZ is used to demonstrate the functio- e

... the equivalent RDSON value. For more accurate measurements, a second voltmeter can be used to monitor the input voltage across the input capacitor. The input supply voltage may need to be adjusted to account for IR drops, especially if large load currents are used. Figure 3 shows a typical curve of ...
Capacitors for Power Factor Correction
Capacitors for Power Factor Correction

... than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individua ...
BDTIC www.BDTIC.com/infineon RF and Protection Devices Low Barrier Schottky Diode BAT62
BDTIC www.BDTIC.com/infineon RF and Protection Devices Low Barrier Schottky Diode BAT62

... Block diagram of a typical power detection network used for mobile phones ................................... 9 Differential peak power detection design consisting of two Schottky diodes (Detector Diode + Reference Diode in one package – BAT62-07L4) being used for temperature compensation .......... ...
AND8273 - Design of a 100 W Active Clamp Forward DC
AND8273 - Design of a 100 W Active Clamp Forward DC

... dc−dc converter. This IC operates from an input supply up to 150 V, thus covering the input voltages usually found in telecom, datacom and 42 V automotive systems. One can also note that the NCP1562 can be used in mains related applications (e.g. desktop, server, flat TVs) as it can be supplied by a ...
Brushless Motors
Brushless Motors

FAN6754WA Highly Integrated Green-Mode PWM Controller FAN6754WA — Highly Integra
FAN6754WA Highly Integrated Green-Mode PWM Controller FAN6754WA — Highly Integra

... Fixed PWM Frequency: 65 kHz Peak-Current-Mode Control ...
DACs
DACs

... o Primary Trade-offs: Need to maximize (VGS - VTH)3 to improve matching => headroom is limited. D & D_b cannot go all the way to positive supply if M1 & M2 are to remain in saturation with maximum output swing. Conclusion: Current-steering DACs have limited output voltage swings, but they can drive ...
ADG752 数据手册DataSheet下载
ADG752 数据手册DataSheet下载

< 1 ... 455 456 457 458 459 460 461 462 463 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report