• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ICL7652 Advanced LinCMOSTM PRECISION
ICL7652 Advanced LinCMOSTM PRECISION

... Chopper-stabilized operational amplifiers offer the best dc performance of any monolithic operational amplifier. This superior performance is the result of using two operational amplifiers -a main amplifier and a nulling amplifier- plus oscillator-controlled logic and two external capacitors to crea ...
ELECTRONIC BALLAST NIK MUHAMMAD FASHAN BIN HUSAIN
ELECTRONIC BALLAST NIK MUHAMMAD FASHAN BIN HUSAIN

... electronic ballast and reduced its cost, some single-stage electronic ballasts have been proposed by integrating PFC circuit into the inverter stage to perform both ...
AD628 High Common-Mode Voltage Programmable Gain
AD628 High Common-Mode Voltage Programmable Gain

... The AD628 is a high common-mode voltage difference amplifier, combined with a user configurable output amplifier (see Figure 28 and Figure 29). Differential mode voltages in excess of 120 V are accurately scaled by a precision 11:1 voltage divider at the input. A reference voltage input is available ...
ACS750xCA-075 - Allegro Microsystems
ACS750xCA-075 - Allegro Microsystems

... been saturated, usually when the device has been subjected to a full-scale or high-current overload condition. The magnetic offset is largely dependent on the material used as a flux concentrator. The larger magnetic offsets are observed at the lower operating temperatures. Accuracy (ETOT). The accu ...
CMOS Schmitt Trigger Test Circuit
CMOS Schmitt Trigger Test Circuit

MAX889 High-Frequency, Regulated, 200mA, Inverting Charge Pump General Description
MAX889 High-Frequency, Regulated, 200mA, Inverting Charge Pump General Description

... in their switching frequencies (f OSC ) — MAX889R/ MAX889S/MAX889T with fOSC = 500kHz/1MHz/2MHz, respectively. Higher frequencies allow the use of smaller components (Table 1). Even smaller capacitor values than those listed in Table 1 are suitable when the devices are loaded at less than their rate ...
MAX8739 TFT, LCD, DC-DC Converter with Operational Amplifiers General Description
MAX8739 TFT, LCD, DC-DC Converter with Operational Amplifiers General Description

... the MAX8739 is from 1.8V to 5.5V. The device also includes a logic-controlled, high-voltage switch with adjustable delay. The step-up DC-DC converter provides the regulated supply voltage for the panel source driver ICs. The converter is a high-frequency (600kHz/1.2MHz) currentmode regulator with an ...
Robust Control of a Doubly Fed Induction Generator (DFIG) Fed by a
Robust Control of a Doubly Fed Induction Generator (DFIG) Fed by a

PTC-04 Datasheet
PTC-04 Datasheet

... The PTC-04 programmer was designed for efficient, precise calibration of the Melexis families of programmable ICs. The programmer is designed to be easily adapted to a standard PC and to an application module to allow calibration of programmable sensor ICs within the operating environment. The PTC-0 ...
G050486-00 - DCC
G050486-00 - DCC

AP8800A Description Pin Assignments
AP8800A Description Pin Assignments

... proportional voltage to the input of the internal comparator. When this voltage reaches an internally set upper threshold, the internal switch is turned off. The inductor current continues to flow through RSET, L1, the LEDs and the schottky diode D1, and back to the supply rail, but it decays, with ...
Godoy, P.A., S. Chung, T.W. Barton, D.J. Perreault, and J.L. Dawson, “A Highly Efficient 1.95-GHz, 18-W Asymmetric Multilevel Outphasing Transmitter for Wideband Applications,” 2011 International Microwave Symposium , pp. 1-4, June 2011.
Godoy, P.A., S. Chung, T.W. Barton, D.J. Perreault, and J.L. Dawson, “A Highly Efficient 1.95-GHz, 18-W Asymmetric Multilevel Outphasing Transmitter for Wideband Applications,” 2011 International Microwave Symposium , pp. 1-4, June 2011.

... generated by MATLAB after characterizing the AMO transmitter with a narrowband training signal. The two phase modulators were each implemented by a 16-bit dual-channel DAC evaluation board from Analog Devices (AD9779A). An FPGA provides the digital inputs to the phase modulators and the discrete sup ...
Title : Feasible Performance Evaluations of Digitally
Title : Feasible Performance Evaluations of Digitally

... present or a new state, the corresponding voltage vector is then subtracted from the reference voltage vector. The resultant vector is denoted in Fig. 4 by the medium reference and represents the balance of the reference vector that is required to be supplemented by the medium and low voltage stages ...
How to do calibration and create Golden DFI for Application Report
How to do calibration and create Golden DFI for Application Report

LT1512
LT1512

... The LT1512 is a current mode switcher. This means that switch duty cycle is directly controlled by switch current rather than by output voltage or current. Referring to the Block Diagram, the switch is turned “on” at the start of each oscillator cycle. It is turned “off” when switch current reaches ...
RC Circuits 2.0
RC Circuits 2.0

... This is a very common situation. In electronic devices that require dc voltages, the power supply typically provides only one or a few fixed voltage levels. There may be many parts of the circuitry that require voltage levels other than those few supplied. In your case, how do you get 4 V from the o ...
Novel Three-Phase CM/DM Conducted Emission Separator
Novel Three-Phase CM/DM Conducted Emission Separator

... of parasitic elements on the noise separation is investigated based on the circuit shown in Fig. 5. There, the transformer has been replaced by an equivalent circuit, which accounts for the leakage (Lσ ) and magnetizing (LM ) inductances, as well as for the parasitic capacitances (C1 . . . C6 ) [23] ...
an oscillator witu constant output voltage
an oscillator witu constant output voltage

D N IAGNOSTIC EWS
D N IAGNOSTIC EWS

... For example if the secondary winding has 600 turns and the primary has one turn (the conductor passing through the center of the core is effectively one turn) then the CT has a ratio of 600:1. If the center conductor is carrying 600 amps, the output from the 600 turn secondary winding is 1.0 amp. Mo ...
VACUUM INTERRUPTER IMPULSE VOLTAGE TESTING
VACUUM INTERRUPTER IMPULSE VOLTAGE TESTING

... that can occur in a power system from normal switching operations or from more abnormal natural causes such as lightning. These ratings do not ensure that any possible overvoltage will be withstood, but the requirements do provide that most typical overvoltages that occur in service will be withstoo ...
Three-Phase TTR® Transformer Turns Ratio Test Set
Three-Phase TTR® Transformer Turns Ratio Test Set

... voltage signal applied to the high voltage winding and the voltage signal extracted from the low voltage winding. The phase deviation together with ratio error can be used as a low cost method of verifying accuracy class of all types of PTs and CTs at “zero burden.” The phase deviation between the h ...
Ch 2 Wiring Slides 042909
Ch 2 Wiring Slides 042909

... • AC – Transformer center tap on shore  Also connected to ground rod at transformer  Wire color is Green and uninterrupted wire • Isolation transformers and galvanic isolators are exception and covered in Chapter 4 on AC ...
model sr540 optical chopper
model sr540 optical chopper

DEIC421 - IXYS Power
DEIC421 - IXYS Power

... short minimum pulse widths. The DEIC421 is an improved version of the DEIC420. The DEIC421 has a Kelvin ground connection on the input side to allow the use of a common mode choke to avoid problems with ground bounce. The internal layout of the package has been improved to reduce inductance. The DEI ...
Our Catalog
Our Catalog

... The building blocks of the system are as follows: 1.) Power Module - A 1000 Watt slave power inverter. It requires drive signals from a Master Module or Control Card as described below. This module is the backbone of the inverter system. 2.) Master Module - A 1000 Watt power inverter which contains ...
< 1 ... 426 427 428 429 430 431 432 433 434 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report