MAX9156 Low-Jitter, Low-Noise LVPECL-to-LVDS Level Translator in an SC70 Package General Description
... intended for point-to-point communication over a controlled-impedance medium, as defined by the ANSI/ TIA/EIA-644 and IEEE 1596.3 standards. The LVDS standard uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reduci ...
... intended for point-to-point communication over a controlled-impedance medium, as defined by the ANSI/ TIA/EIA-644 and IEEE 1596.3 standards. The LVDS standard uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reduci ...
RF3194 QUAD-BAND GSM POWER AMP MODULE Features
... impedance presented to the PA varies, so does the output power and current to the power amplifier. If left uncontrolled, power amplifier current can peak at high levels that starve other circuitry, connected to the same supply, of the required voltage to operate. This can result in a reset or shutdo ...
... impedance presented to the PA varies, so does the output power and current to the power amplifier. If left uncontrolled, power amplifier current can peak at high levels that starve other circuitry, connected to the same supply, of the required voltage to operate. This can result in a reset or shutdo ...
Issues, Models and Solutions for Triac Modulated Phase Dimming of
... discharged to approximately Vf (about 1V) to reset the capacitor and to remove the gate drive to the triac. This behavior is accomplished by using E2 to monitor the voltage across the triac and discharge C1 through S1 whenever the triac is on (when voltage is between –3V and 3V). The discharge of th ...
... discharged to approximately Vf (about 1V) to reset the capacitor and to remove the gate drive to the triac. This behavior is accomplished by using E2 to monitor the voltage across the triac and discharge C1 through S1 whenever the triac is on (when voltage is between –3V and 3V). The discharge of th ...
Final Draft Standards Inverters ed 2
... Note: Safety requirements ensure that electrical equipment constructed in accordance with these standards does not endanger the safety of person or property when properly installed, maintained, and used in applications for which it was intended. SECTION ONE - GENERAL REQUIREMENTS 1. SCOPE This stand ...
... Note: Safety requirements ensure that electrical equipment constructed in accordance with these standards does not endanger the safety of person or property when properly installed, maintained, and used in applications for which it was intended. SECTION ONE - GENERAL REQUIREMENTS 1. SCOPE This stand ...
Draft Tariff Language - ReactivePowerRequirements and Financial
... without the need for such a showing in the Phase II Interconnection Study. The Generating Unit will maintain a composite power delivery at continuous rated power output at the high-side of the generator substation at a power factor within the range of 0.95 leading to 0.95 lagging, unless the CAISO h ...
... without the need for such a showing in the Phase II Interconnection Study. The Generating Unit will maintain a composite power delivery at continuous rated power output at the high-side of the generator substation at a power factor within the range of 0.95 leading to 0.95 lagging, unless the CAISO h ...
Frequently Asked Questions Solid-State Relays Frequently Asked
... (Ron) is increased and the current is held at its limit value. The SSR resumes its normal operation when the excessive current is removed. This is not a continuous operation mode but a basic protection against overcurrent transients. For more information see the application note: www.vishay.com/doc? ...
... (Ron) is increased and the current is held at its limit value. The SSR resumes its normal operation when the excessive current is removed. This is not a continuous operation mode but a basic protection against overcurrent transients. For more information see the application note: www.vishay.com/doc? ...
Low-Dropout Regulator with modest ripple and rugged performance
... current (ΔILOAD) define load regulation(LDR) performance Systematic input-offset voltages, which result from asymmetric currents and volt-ages in the feedback error amplifier, further degrade load-regulation performance Even if the LDO were symmetric, its widely variable load would cause conside ...
... current (ΔILOAD) define load regulation(LDR) performance Systematic input-offset voltages, which result from asymmetric currents and volt-ages in the feedback error amplifier, further degrade load-regulation performance Even if the LDO were symmetric, its widely variable load would cause conside ...
Integrating Bourns® Resistive Products to Control Current and
... LED lighting has grown rapidly in popularity over the past several years, and there is no sign that this trend will change. Whether for refrigeration, industrial, automotive, residential, or consumer electronics, there are several points many LED lighting circuits have in common. Guidelines for circ ...
... LED lighting has grown rapidly in popularity over the past several years, and there is no sign that this trend will change. Whether for refrigeration, industrial, automotive, residential, or consumer electronics, there are several points many LED lighting circuits have in common. Guidelines for circ ...
Dynamic Safe-area Protection for Power Transistors Employs Peak
... [1] – [5]. However, thermal coupling between the sensor and the power transistor has not been good enough that temperature sensing alone could provide adequate protection. Located right at the edge of a power array, a conventional thermal sensor detects only 60-percent of the peak junction-to-case t ...
... [1] – [5]. However, thermal coupling between the sensor and the power transistor has not been good enough that temperature sensing alone could provide adequate protection. Located right at the edge of a power array, a conventional thermal sensor detects only 60-percent of the peak junction-to-case t ...
Wireless Inductive Charging for Low Power Devices
... When the resonant frequency of the changing electromagnetic field is relatively low around one megahertz and the transfer distance is only few centimetres that belongs to the near-field power transfer. Higher frequencies in the range of gigahertz employ longer distances which fall in the Far field tra ...
... When the resonant frequency of the changing electromagnetic field is relatively low around one megahertz and the transfer distance is only few centimetres that belongs to the near-field power transfer. Higher frequencies in the range of gigahertz employ longer distances which fall in the Far field tra ...
Keysight Technologies Power Conversion Efficiency Measurement
... Power analyzers for power and efficiency measurements Many power analyzers are designed specifically to provide easy and accurate efficiency measurements. These instruments typically have multiple isolated inputs to measure voltage and current simultaneously on the input and output of a power conver ...
... Power analyzers for power and efficiency measurements Many power analyzers are designed specifically to provide easy and accurate efficiency measurements. These instruments typically have multiple isolated inputs to measure voltage and current simultaneously on the input and output of a power conver ...
LT1533 - Ultralow Noise1A Switching Regulator
... architecture optimized for low noise topologies. The IC includes two 1A power switches along with all necessary oscillator, control and protection circuitry. Unique error amp circuitry can regulate both positive and negative voltages. The internal oscillator may be synchronized to an external clock ...
... architecture optimized for low noise topologies. The IC includes two 1A power switches along with all necessary oscillator, control and protection circuitry. Unique error amp circuitry can regulate both positive and negative voltages. The internal oscillator may be synchronized to an external clock ...
Technical Data
... Control Centers, Panelboards and Busway. The Visor can also be externally mounted to existing distribution equipment. Standard NEMA 1/3R retrofit enclosure. NEMA 4X, Flushmount and NEMA 12 enclosure available as an option. Enclosures with disconnect switch available as an option. The Visor is availa ...
... Control Centers, Panelboards and Busway. The Visor can also be externally mounted to existing distribution equipment. Standard NEMA 1/3R retrofit enclosure. NEMA 4X, Flushmount and NEMA 12 enclosure available as an option. Enclosures with disconnect switch available as an option. The Visor is availa ...
Introduction to Solid State Electronics_independent_study
... positive terminal of the power supply. This causes the ID to flow through the p-n junction, from positive terminal to the negative terminal of the power supply. On the other hand, if we connect the positive and negative terminals of a power supply to the n-type and p-type semiconductors, respectivel ...
... positive terminal of the power supply. This causes the ID to flow through the p-n junction, from positive terminal to the negative terminal of the power supply. On the other hand, if we connect the positive and negative terminals of a power supply to the n-type and p-type semiconductors, respectivel ...
MAX8540/MAX8541 Synchronizable, High-Frequency Current- and Voltage-Mode PWM Controllers for Isolated Supplies General Description
... Maximum duty cycle is adjustable, and the feed-forward function scales the maximum duty cycle with input voltage to limit the maximum volt-seconds applied to the transformer primary. The MAX8540 allows the user to select the value of slope compensation to further optimize magnetics design. The MAX85 ...
... Maximum duty cycle is adjustable, and the feed-forward function scales the maximum duty cycle with input voltage to limit the maximum volt-seconds applied to the transformer primary. The MAX8540 allows the user to select the value of slope compensation to further optimize magnetics design. The MAX85 ...
IGC193T120T8RM IGBT4 Medium Power Chip
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
Installation Instruction Sheet for Vision Site Small LED
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
Low-Cost Programmable Battery Dischargers and Application in
... and new battery technologies, but also on ways of optimal battery use. To get optimal performance and lifetime of a battery pack, it is very useful to know its internal states precisely. For this purpose a wide range of battery models have been developed, simulating different physical phenomena with ...
... and new battery technologies, but also on ways of optimal battery use. To get optimal performance and lifetime of a battery pack, it is very useful to know its internal states precisely. For this purpose a wide range of battery models have been developed, simulating different physical phenomena with ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.