• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Off-Grid Series User Manual
Off-Grid Series User Manual

... or enclosure installations, always vent batteries to the outside. Provide at least one inch of air space between batteries to provide optimum cooling. Never smoke when in the vicinity of batteries. Always connect the cables to the batteries first. Use insulated tools at all times. Always verify prop ...
ZABG4002
ZABG4002

... depletion mode FETs used in common source circuit configuration as shown above. This converter uses two external capacitors, CNB the charge transfer capacitor and CSUB the output reservoir capacitor. The circuit provides a regulated -2.5V supply both for gate driver use and for external use if requi ...
Modeling and Control of VSI type FACTS controllers for
Modeling and Control of VSI type FACTS controllers for

Reduction of Circulating Current Flow in Parallel
Reduction of Circulating Current Flow in Parallel

... The power quality, at all time, is a matter of concern where a number of non-linear, harmonics producing and sophisticated loads are connected in a electrical distribution network. In that case APFsh is finding greater applications for power quality (PQ) improvement in the distributed network. In hi ...
TVSS Series STABILINE Transient Voltage Surge Suppressors ®
TVSS Series STABILINE Transient Voltage Surge Suppressors ®

... recommended for top-level protection? Reliable data sources illustrate that some “non-typical” current magnitudes may be in excess of 200,000 amps. Additionally, lightning strikes often consist of four to six consecutive “hits” and may be as many as 40. Therefore, suppression filter systems must pro ...
Signal Value Breadboard Description VDD 3.3V TOP “+”row Always
Signal Value Breadboard Description VDD 3.3V TOP “+”row Always

... Figure 8: Connection to test the function of the light tracker input. DISCONNECT the 3.3V power supply after test. 5.2 Test Breadboard Based on your circuit above, connect the light tracker to the LONG breadboard according to Figure 8. Note the following: • In the final circuit, VDD from the Basys2 ...
D.C. GENERATOR
D.C. GENERATOR

... The individual forces F on different conductors all act clockwise In effect they produce torque that acts opposite to the direction in which the generator is driven by a driver e.g., a turbine. Therefore, the prime mover or driver tends to slow down and need more torque to keep the generator going o ...
Full-Text - Radioengineering
Full-Text - Radioengineering

... having three inputs and single output, can realize voltagemode low-pass, band-pass, high-pass, band-stop, and allpass filters. The biquad filters have low output impedances that is necessary for cascadability for voltage mode circuits, and no critical component matching conditions are required. For ...
AN-812 APPLICATION NOTE
AN-812 APPLICATION NOTE

... This application note describes the operation of a generalpurpose, microcontroller-based Serial Port Interface (SPI) boot circuit. This is a low cost solution for users who need to modify some of their device’s parameters at power up. This circuit addresses a 3-wire SPI application for programming c ...
Film Capacitors - Power Factor Correction - MKP440-D-15
Film Capacitors - Power Factor Correction - MKP440-D-15

... than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individua ...
Capture Energy by Circuit Breaker Communication
Capture Energy by Circuit Breaker Communication

... information, such as phase currents or diagnosis data, load warnings or diagnosis messages of the circuit breaker are made available via the SmartWire-DT™. All NZM 2/3/4 breakers with an electronic tripping unit can directly be connected to the SmartWire-DT™ via the NZM module. Currents up to 1600 A ...
EEP/402- Power system protection
EEP/402- Power system protection

...  Students will be able to understand the principle of speed control techniques used in various electrical drives.  Students will be able to select proficiently and the proper electrical drive system for particular application.  Students will have ability to analyze the performance of electrical d ...
MAX8576–MAX8579 3V to 28V Input, Low-Cost, Hysteretic Synchronous Step-Down Controllers General Description
MAX8576–MAX8579 3V to 28V Input, Low-Cost, Hysteretic Synchronous Step-Down Controllers General Description

... internal LDO regulator allowing the controllers to function from only one 3V to 28V input supply. The MAX8578/MAX8579 do not contain the internal LDO and require a separate supply to power the IC when the input supply is higher than 5.5V. The MAX8576– MAX8579 output voltages are adjustable from 0.6V ...
2.5.2 Class 1E Uninterruptible Power Supply Design Description 1.0
2.5.2 Class 1E Uninterruptible Power Supply Design Description 1.0

... Each EUPS battery is able to provide power for starting and operating design loads for a minimum of two hours when the ac supply to the battery charger is lost. ...
LT1166 - Power Output Stage Automatic Bias
LT1166 - Power Output Stage Automatic Bias

... same voltage on the (–) inputs and these voltages then appear on the sense resistors in series with the power devices. The product of the two currents in the power devices is constant, as one increases the other decreases. The excellent logging nature of Q9 and Q10 allows this relation to hold over ...
BDTIC www.BDTIC.com/infineon F3L030E07-F-W2_EVAL Evaluation Board for Easy2B 3-Level Modules in
BDTIC www.BDTIC.com/infineon F3L030E07-F-W2_EVAL Evaluation Board for Easy2B 3-Level Modules in

... The IGBT DCB temperature can be monitored by proper usage of the NTC resistor built into the module. The evaluation of the temperature information requires an external circuit. Further information on using the NTC including the NTC characteristics is described in application note AN2009-10 [2]. Noti ...
Aalborg Universitet Droop Controlled DC Microgrid
Aalborg Universitet Droop Controlled DC Microgrid

LT1373 - 250kHz Low Supply Current High Efficiency 1.5A
LT1373 - 250kHz Low Supply Current High Efficiency 1.5A

MAX1910/MAX1912 1.5x/2x High-Efficiency White LED Charge
MAX1910/MAX1912 1.5x/2x High-Efficiency White LED Charge

... The MAX1910/MAX1912 include soft-start circuitry to limit inrush current at turn-on. When starting up with the output voltage at zero, the output capacitor charges through a ramped current source, directly from the input with no charge-pump action until the output voltage is near the input voltage. ...
MAX16814 Integrated, 4-Channel, High-Brightness LED Driver with High-Voltage DC-DC Controller EVALUATION KIT AVAILABLE
MAX16814 Integrated, 4-Channel, High-Brightness LED Driver with High-Voltage DC-DC Controller EVALUATION KIT AVAILABLE

... The MAX16814 consists of four identical linear current source channels to drive four strings of HB LEDs. The channel current is adjustable from 20mA to 150mA with an accuracy of ±3% using an external resistor. The external resistor sets all 4-channel currents to the same value. The device allows con ...
Comparison of cost and efficiency of DC versus AC in
Comparison of cost and efficiency of DC versus AC in

... It has been known for a long time that direct current (DC) is potentially more convenient, in terms of efficiency, in the transmission of electrical energy than three-phase current and, a fortiori, singlephase current. Losses that occur in cables are potentially lower for DC than AC, because the cab ...
PowerPoint-Präsentation
PowerPoint-Präsentation

... competition.The ability of the transmission systems to deliver the energy is dependent on several main factors that are constraining the system, including thermal constraints, voltage constraints, and stability constraints. These transmission limitations are usually determined by performing detailed ...
review: design of high radix addition in deep submicron technology
review: design of high radix addition in deep submicron technology

... In [1] the quaternary 16 X 1 multiplexer logic design using transmission gate on 130nm technology with maximum supply voltage of 1.2V. The maximum power consumption of this work was 122uW. The architecture is base on switch like structure of transmission gate but is not immune to noise in circuit. T ...
REFURBISHMENT and VERIFICATION of the HEATHKIT TT
REFURBISHMENT and VERIFICATION of the HEATHKIT TT

Basic Electric Transformers
Basic Electric Transformers

... for all students working in groups of, say, four or five to a team. The students can decide for themselves whether they help assemble the transformer “core” or to help wind the two coils. (Note that all these components can be re-used many times over, so there is no wastage). See Figs 8 – 13. Depend ...
< 1 ... 362 363 364 365 366 367 368 369 370 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report