MAX8759 Low-Cost, SMBus, CCFL Backlight Controller General Description Features
... using a full-bridge resonant inverter. The resonant operation ensures reliable striking and provides near-sinusoidal waveforms over the entire input range. The controller operates over a wide input-voltage range of 4.5V to 28V with high power to light efficiency. The device also includes safety feat ...
... using a full-bridge resonant inverter. The resonant operation ensures reliable striking and provides near-sinusoidal waveforms over the entire input range. The controller operates over a wide input-voltage range of 4.5V to 28V with high power to light efficiency. The device also includes safety feat ...
ILXGHB Series
... Capacitor and starter (HPS models) are mounted on a separate slide-out plate to faciliate field maintenance. 180°C (356°F) Class H insulation system. Crest factor does not exceed 1.8. ILXR Regulated Lag ballast also available. Optional Electronic ballast available for 320-450W PSMH units. ...
... Capacitor and starter (HPS models) are mounted on a separate slide-out plate to faciliate field maintenance. 180°C (356°F) Class H insulation system. Crest factor does not exceed 1.8. ILXR Regulated Lag ballast also available. Optional Electronic ballast available for 320-450W PSMH units. ...
2 - Electrical Contractor Network
... spasms from even a mild shock may lead to a fall from a height or cause heart problems which are not readily noticeable or in certain circumstances cause death by electrocution. The main causes for death or serious injury while welding are as follows: : 1. Poorly maintained or badly connected equipm ...
... spasms from even a mild shock may lead to a fall from a height or cause heart problems which are not readily noticeable or in certain circumstances cause death by electrocution. The main causes for death or serious injury while welding are as follows: : 1. Poorly maintained or badly connected equipm ...
System Requirements for Wind Power Plants
... fault may however take place at high wind speeds. In this case the in-rush current may be significantly higher if the wind-induced torque is not limited by pitching the blades. The capacitors may be connected in one or more steps. Capacitors for connection in one step commonly provide about zero rea ...
... fault may however take place at high wind speeds. In this case the in-rush current may be significantly higher if the wind-induced torque is not limited by pitching the blades. The capacitors may be connected in one or more steps. Capacitors for connection in one step commonly provide about zero rea ...
DATA SHEET Tytan II D0-63-3/V
... all empty housings are supplied with fitted cartridges that can accept fuse plug sets up to 63 A, all variants are supplied without fuses. These can be obtained separately. ...
... all empty housings are supplied with fitted cartridges that can accept fuse plug sets up to 63 A, all variants are supplied without fuses. These can be obtained separately. ...
LT3022/LT3022-1.2 LT3022-1.5/LT3022-1.8
... DFN and MSOP packages. L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Linear Technology Corporation. VLDO is a trademark of Linear Technology Corporation. ...
... DFN and MSOP packages. L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Linear Technology Corporation. VLDO is a trademark of Linear Technology Corporation. ...
ZXLD1350Q Description Pin Assignments Features Typical
... The ZXLD1350Q is a hysteretic mode inductive step-down converter with integrated switch and high side current sense. It operates from an input supply from 7V to 30V driving single or multiple series connected LEDs efficiently external adjustable output current up to 350mA. ...
... The ZXLD1350Q is a hysteretic mode inductive step-down converter with integrated switch and high side current sense. It operates from an input supply from 7V to 30V driving single or multiple series connected LEDs efficiently external adjustable output current up to 350mA. ...
S280-75-2
... The front panel is backed by a printed-circuit tie board which supports and interfaces the plug-in circuit boards with other related circuit components (Figure 3). Program-altering, remote control, indicating, and general convenience accessories can be added to further expand and enhance the applica ...
... The front panel is backed by a printed-circuit tie board which supports and interfaces the plug-in circuit boards with other related circuit components (Figure 3). Program-altering, remote control, indicating, and general convenience accessories can be added to further expand and enhance the applica ...
OCCUPATIONAL HEALTH AND SAFETY ACT - O
... (3) Only a worker who meets the requirements of clause 182 (1) (a) or (b) shall perform the work. (4) The constructor shall, (a) ensure that written measures and procedures for complying with this section are established and implemented, so that workers are adequately protected from electrical shock ...
... (3) Only a worker who meets the requirements of clause 182 (1) (a) or (b) shall perform the work. (4) The constructor shall, (a) ensure that written measures and procedures for complying with this section are established and implemented, so that workers are adequately protected from electrical shock ...
Megatest 5000 V Megohmmeter Product Manual
... installations or equipment complies with the relevant regulations. Measurements taken in the "PROGR" mode make it possible to increase the voltage slowly. This way the efficiency of an insulator can be checked out, the insulation resistance should stay more or less the same even when the voltage is ...
... installations or equipment complies with the relevant regulations. Measurements taken in the "PROGR" mode make it possible to increase the voltage slowly. This way the efficiency of an insulator can be checked out, the insulation resistance should stay more or less the same even when the voltage is ...
LTC4002- 2-Cell Standalone Li-Ion Switch Mode Battery Charger
... current drops below the End-of-Charge threshold for more than 120µs, the N-channel MOSFET turns off and a 25µA current source is connected from the CHRG pin to GND. When the timer runs out or the input supply is removed, the 25µA current source is turned off and the CHRG pin becomes high impedance. ...
... current drops below the End-of-Charge threshold for more than 120µs, the N-channel MOSFET turns off and a 25µA current source is connected from the CHRG pin to GND. When the timer runs out or the input supply is removed, the 25µA current source is turned off and the CHRG pin becomes high impedance. ...
OPA2604AUG4中文资料
... Op amp noise is described by two parameters—noise voltageand noise current. The voltage noise determines the noiseperformance with low source impedance. Low noise bipolar-input op amps such as the OPA27 and OPA37 provide verylow voltage noise. But if source impedance is greater than afew thousand oh ...
... Op amp noise is described by two parameters—noise voltageand noise current. The voltage noise determines the noiseperformance with low source impedance. Low noise bipolar-input op amps such as the OPA27 and OPA37 provide verylow voltage noise. But if source impedance is greater than afew thousand oh ...
(ii) Three-phase transformer
... The basic principle behind working of a transformer is the phenomenon of mutual induction between two windings linked by common magnetic flux. Basically a transformer consists of two inductive coils; primary winding and secondary winding. The coils are electrically separated but magnetically linked ...
... The basic principle behind working of a transformer is the phenomenon of mutual induction between two windings linked by common magnetic flux. Basically a transformer consists of two inductive coils; primary winding and secondary winding. The coils are electrically separated but magnetically linked ...
5. Circuit breakers protecting final-distribution
... space and all live components inside. The impact strength as per IEC 62262 shall be IK08. Large enclosures (24 modules wide) shall be fitted with metal reinforcements to increase the rigidity of equipped enclosures for shipping, handling, installation, etc. For enclosures supplying the following par ...
... space and all live components inside. The impact strength as per IEC 62262 shall be IK08. Large enclosures (24 modules wide) shall be fitted with metal reinforcements to increase the rigidity of equipped enclosures for shipping, handling, installation, etc. For enclosures supplying the following par ...
MAX17410 Dual-Phase, Quick-PWM Controller for IMVP6+ CPU Core Power Supplies General Description
... notebook IMVP6+ CPUs. True out-of-phase operation reduces input ripple current requirements and output voltage ripple while easing component selection and layout difficulties. The Quick-PWM control scheme provides instantaneous response to fast load current steps. Active voltage positioning reduces ...
... notebook IMVP6+ CPUs. True out-of-phase operation reduces input ripple current requirements and output voltage ripple while easing component selection and layout difficulties. The Quick-PWM control scheme provides instantaneous response to fast load current steps. Active voltage positioning reduces ...
P83884
... CAUTION: Check the installation instructions of the manufacturers of other equipment used in the system for any guidelines or restrictions on wiring and/or locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for exampl ...
... CAUTION: Check the installation instructions of the manufacturers of other equipment used in the system for any guidelines or restrictions on wiring and/or locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for exampl ...
3 nV/√Hz, Low Power Instrumentation Amplifier AD8421
... 200 fA/√Hz current noise with only 2 mA quiescent current, making it an ideal choice for measuring low level signals. For applications with high source impedance, the AD8421 employs innovative process technology and design techniques to provide noise performance that is limited only by the sensor. T ...
... 200 fA/√Hz current noise with only 2 mA quiescent current, making it an ideal choice for measuring low level signals. For applications with high source impedance, the AD8421 employs innovative process technology and design techniques to provide noise performance that is limited only by the sensor. T ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.