MAX3054/MAX3055/MAX3056 ±80V Fault-Protected/Tolerant CAN Transceivers for In-Car Applications General Description
... The MAX3054/MAX3055/MAX3056 are interfaces between the protocol controller and the physical wires of the bus lines in a controller area network (CAN). The devices provide differential transmit capability and switch to single-wire mode if certain fault conditions occur. The MAX3054/MAX3055/MAX3056 gu ...
... The MAX3054/MAX3055/MAX3056 are interfaces between the protocol controller and the physical wires of the bus lines in a controller area network (CAN). The devices provide differential transmit capability and switch to single-wire mode if certain fault conditions occur. The MAX3054/MAX3055/MAX3056 gu ...
MAX13085E +5.0V, ±15kV ESD-Protected, Fail-Safe, Hot-Swap, RS-485/RS-422 Transceiver General Description
... Capability section). The MAX13085E features reduced slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables, allowing error-free data transmission up to 500kbps. The MAX13085E is a half-duplex transceiver and operates from a single +5.0V supply. Drivers are ...
... Capability section). The MAX13085E features reduced slew-rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables, allowing error-free data transmission up to 500kbps. The MAX13085E is a half-duplex transceiver and operates from a single +5.0V supply. Drivers are ...
BD95835EFJ
... Use of the IC in excess of absolute maximum ratings may result in damage to the IC. Assumptions should not be made regarding the state of the IC (e.g., short mode or open mode) when such damage is suffered. If operational values are expected to exceed the maximum ratings for the device, consider add ...
... Use of the IC in excess of absolute maximum ratings may result in damage to the IC. Assumptions should not be made regarding the state of the IC (e.g., short mode or open mode) when such damage is suffered. If operational values are expected to exceed the maximum ratings for the device, consider add ...
LM2599 SIMPLE SWITCHER Power Converter 150 kHz 3A Step
... FIGURE 1. Standard Test Circuits and Layout Guides As in any switching regulator, layout is very important. Rapidly switching currents associated with wiring inductance can generate voltage transients which can cause problems. For minimal inductance and ground loops, the wires indicated by heavy lin ...
... FIGURE 1. Standard Test Circuits and Layout Guides As in any switching regulator, layout is very important. Rapidly switching currents associated with wiring inductance can generate voltage transients which can cause problems. For minimal inductance and ground loops, the wires indicated by heavy lin ...
Transmission-Line Fault Analysis Using
... range of operating conditions (varying system loading, fault resistance, fault inception instance, etc.), ANN-based methods have been successful in detecting and classifying the faults, but they need a huge amount of training cases to achieve good performance. A combination of fuzzy set and wavelet ...
... range of operating conditions (varying system loading, fault resistance, fault inception instance, etc.), ANN-based methods have been successful in detecting and classifying the faults, but they need a huge amount of training cases to achieve good performance. A combination of fuzzy set and wavelet ...
- IEEE Mentor
... compartments that are adjacent to each other but separated by barriers from the transformer and each other. Access is through padlocked hinged doors designed so that unauthorized personnel cannot enter either compartment. Where ventilating openings are provided, tamper-resistant grills are used. Gau ...
... compartments that are adjacent to each other but separated by barriers from the transformer and each other. Access is through padlocked hinged doors designed so that unauthorized personnel cannot enter either compartment. Where ventilating openings are provided, tamper-resistant grills are used. Gau ...
MAX4645/6 DS
... all CMOS devices. Do not exceed the absolute maximum ratings because stresses beyond the listed ratings can cause permanent damage to the devices. Always sequence V+ on first, followed by the logic inputs, NO, or COM. If power-supply sequencing is not possible, add two small signal diodes (D1, D2) i ...
... all CMOS devices. Do not exceed the absolute maximum ratings because stresses beyond the listed ratings can cause permanent damage to the devices. Always sequence V+ on first, followed by the logic inputs, NO, or COM. If power-supply sequencing is not possible, add two small signal diodes (D1, D2) i ...
OPA660 Wide Bandwidth OPERATIONAL TRANSCONDUCTANCE
... The OPA660 is a versatile monolithic component designed for wide-bandwidth systems including high performance video, RF and IF circuitry. It includes a wideband, bipolar integrated voltage-controlled current source and voltage buffer amplifier. The voltage-controlled current source or Operational Tr ...
... The OPA660 is a versatile monolithic component designed for wide-bandwidth systems including high performance video, RF and IF circuitry. It includes a wideband, bipolar integrated voltage-controlled current source and voltage buffer amplifier. The voltage-controlled current source or Operational Tr ...
Electrical power transformer
... The transformer is an electrical component in the distribution of power on the grid and other power systems. This thesis identifies various aspects of the transformer. The first part of the paper provides an overview of the general operation principle of the transformer. In addition, it highlights o ...
... The transformer is an electrical component in the distribution of power on the grid and other power systems. This thesis identifies various aspects of the transformer. The first part of the paper provides an overview of the general operation principle of the transformer. In addition, it highlights o ...
Inspecting Electrical
... Look for signs of corrosion outside and at interior connections Look for circuit breakers that have more than one conductor attached • (Double or triple tapping is normally prohibited) ...
... Look for signs of corrosion outside and at interior connections Look for circuit breakers that have more than one conductor attached • (Double or triple tapping is normally prohibited) ...
Installation and Owner`s Manual Air-cooled, Prepackaged
... ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in operation. Avoid contact with bare wi ...
... ELECTRICAL HAZARDS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in operation. Avoid contact with bare wi ...
max3221-max3243.pdf
... current with Maxim’s revolutionary AutoShutdown™ feature. When the MAX3221/MAX3223/MAX3243 do not sense a valid signal level on their receiver inputs, the on-board power supply and drivers shut down. This occurs if the RS-232 cable is disconnected or if the transmitters of the connected peripheral a ...
... current with Maxim’s revolutionary AutoShutdown™ feature. When the MAX3221/MAX3223/MAX3243 do not sense a valid signal level on their receiver inputs, the on-board power supply and drivers shut down. This occurs if the RS-232 cable is disconnected or if the transmitters of the connected peripheral a ...
SCREEN GRIDS in - Music Electronics Forum
... feedback, and push-pull hum cancellation to produce an acceptable product. Very few amplifiers included regulated power supplies for their Screen-Grids, because of increased manufacturing cost. Although the RCA Receiving Tube Manuals published schematics incorporating Screen-Grid regulation, the mos ...
... feedback, and push-pull hum cancellation to produce an acceptable product. Very few amplifiers included regulated power supplies for their Screen-Grids, because of increased manufacturing cost. Although the RCA Receiving Tube Manuals published schematics incorporating Screen-Grid regulation, the mos ...
2012 Canadian Electrical Code, Part I (CEC) Top
... Description: Traditionally, switches and receptacles are installed in boxes that are installed during the “rough-in” stage of an electrical installation. “Self contained” receptacles and switches are manufactured with an integral box, meaning that a box is not required to be installed during rough-i ...
... Description: Traditionally, switches and receptacles are installed in boxes that are installed during the “rough-in” stage of an electrical installation. “Self contained” receptacles and switches are manufactured with an integral box, meaning that a box is not required to be installed during rough-i ...
Principles of Electronic Communication Systems
... transmit information from one place to another. Light is a type of electromagnetic radiation like radio waves. Today, infrared light is being used increasingly as the carrier for information in communication systems. The transmission medium is either free space or a light-carrying cable called a fib ...
... transmit information from one place to another. Light is a type of electromagnetic radiation like radio waves. Today, infrared light is being used increasingly as the carrier for information in communication systems. The transmission medium is either free space or a light-carrying cable called a fib ...
All Button and OneTouch Control Systems Installation Manual
... 1.7. A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors ...
... 1.7. A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors ...
TPS62660 数据资料 dataSheet 下载
... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolu ...
Liebert RDC™ Remote Distribution Cabinet
... IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSIDE FRONT COVER ...
... IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSIDE FRONT COVER ...
earth leakage relays
... Installation work must be carried out by qualified personnel. BEFORE INSTALLATION, ISOLATE THE SUPPLY. Connect the unit as shown in the diagram below (N.B. certain features may not be required and therefore do not need to be connected). Operational and setting information can be found on the reverse ...
... Installation work must be carried out by qualified personnel. BEFORE INSTALLATION, ISOLATE THE SUPPLY. Connect the unit as shown in the diagram below (N.B. certain features may not be required and therefore do not need to be connected). Operational and setting information can be found on the reverse ...
ZXCT1008 Description Pin Assignments
... B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regul ...
... B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regul ...
A Novel Technique for Driving Capability
... In this range, all MOSFETs are biased in active region and the buffer is operated on class-A. Comparing (11) and (4) illustrates that the output resistance of the proposed buffer is three times smaller than the buffer in Fig.1. In fact, it is not fair to compare like this because power consumption a ...
... In this range, all MOSFETs are biased in active region and the buffer is operated on class-A. Comparing (11) and (4) illustrates that the output resistance of the proposed buffer is three times smaller than the buffer in Fig.1. In fact, it is not fair to compare like this because power consumption a ...
Subthreshold FinFET for Low Power Circuit Operation: A Study of
... building such devices pose several problems. The fabrication process for double gate devices being more complicated than that for planar devices, the chances of non-uniformity across a wafer during fabrication are increased. These increased process variations could adversely affect the electrical ch ...
... building such devices pose several problems. The fabrication process for double gate devices being more complicated than that for planar devices, the chances of non-uniformity across a wafer during fabrication are increased. These increased process variations could adversely affect the electrical ch ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.