• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
V-Pro Instructions
V-Pro Instructions

... This guarantee states Varilight’s entire liability, which does not extend to cover consequential loss or damage or installation costs arising from a defective product. The guarantee does not apply to problems arising from any incompatibility between your lamps and the dimmer switch. This guarantee d ...
Electrical Safety Rules
Electrical Safety Rules

... PREPARED BY: ...
KA79MXX / LM79MXX 3-Terminal 0.5 A Negative Voltage Regulator KA79MXX /
KA79MXX / LM79MXX 3-Terminal 0.5 A Negative Voltage Regulator KA79MXX /

... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
LM4950 7.5W Mono-BTL or 3.1W Stereo Audio
LM4950 7.5W Mono-BTL or 3.1W Stereo Audio

N E P A L   N A T I O N A L   B U I L D I N G C O D E ELECTRICAL
N E P A L N A T I O N A L B U I L D I N G C O D E ELECTRICAL

... as long as breaker installed upstream having breaking capacity greater than or equall to prospective short circuit current at the point of installation exists. c) Discrimination : At the design stage of low voltage installation one must be sure that the co-ordination of automatic protecting devices ...
Shannon Optimization Project
Shannon Optimization Project

... It is not practical to use Shannonization on an arbitrarily large circuit because any particular input soon has little influence on the gates deep in its logic cone. The cofactors are better when they are more independent, so the distance between inputs and multiplexers is better kept to a reasonabl ...
TJA 1050 CAN High-Speed Transceiver
TJA 1050 CAN High-Speed Transceiver

36-V, Precision, Rail-to-Rail Input/Output, Low Offset Voltage Op
36-V, Precision, Rail-to-Rail Input/Output, Low Offset Voltage Op

... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Introduction - Nuclear Community
Introduction - Nuclear Community

μ  PD166020T1F Data Sheet
μ PD166020T1F Data Sheet

... The dynamic clamp circuit works only when the inductive load is switched off. When the inductive load is switched off, the voltage of OUT falls below 0 V. The gate voltage of SW1 is then nearly equal to GND because the IS terminal is connected to GND via an external resister. Next, the voltage at th ...
TPS60300 数据资料 dataSheet 下载
TPS60300 数据资料 dataSheet 下载

... same time, but the total output current of the first voltage doubler must not exceed 40 mA. For example, the load at OUT1 is 20 mA and the load at output 2 is 10 mA. The devices operate in the newly developed LinSkip mode. In this operating mode, the device switches seamlessly from the power saving, ...
ZXTC2063E6 Features Mechanical Data
ZXTC2063E6 Features Mechanical Data

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
alternators
alternators

... controlled in detail. High operating reliability is assured by optimizing the design for use in different operating conditions, together with numerous validations of different alternators in our own laboratories and with field tests ...
TPS43000 数据资料 dataSheet 下载
TPS43000 数据资料 dataSheet 下载

... PFM mode, a shutdown current of less than 1 µA, a sleep-mode current of less than 100 µA and a full operating current of less than 2 mA at 1 MHz, it is ideal for building highly efficient, dc-to-dc converters. The TPS43000 operates over a wide input voltage range of 1.8 V to 9.0 V. Typical power sou ...
The 9th IEEE International Conference on Power Electronics and
The 9th IEEE International Conference on Power Electronics and

HMC-C058
HMC-C058

... (Bias current increases with switching rate to 15 - 20 mA.) ...
Manual PT C. 1000/2000/3000 (EN) - AEG PS
Manual PT C. 1000/2000/3000 (EN) - AEG PS

S270-15-2
S270-15-2

... as reclosers or reclosing circuit-breakers, to automatically isolate faulted sections of electrical distribution systems. The sectionalizer senses current flow above a preset level, and when the source-side protective device opens to deenergize the circuit, the sectionalizer counts the overcurrent i ...
S8VM (15/30/50/100/150/300/600/1,500
S8VM (15/30/50/100/150/300/600/1,500

... 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection function and interrupt the output. When adjusting the output voltage, confirm the actual ou ...
COLLEGE OF ENGINEERING INSTITUTION OF ENGINEERS
COLLEGE OF ENGINEERING INSTITUTION OF ENGINEERS

Relaying Current Transformer Application
Relaying Current Transformer Application

... In an ideal current transformer, the primary ampere-turns are equal to the secondary ampere-turns. However, every core material requires some energy to produce the magnetic flux that induces the secondary voltage necessary to deliver the secondary current. In an actual current transformer, the secon ...
ALS60/61 Series, +85°C
ALS60/61 Series, +85°C

... 2 V. As a result, the capacitor can withstand a voltage reversal of up to 2 V for short periods. Above this voltage, the formation process will commence. Aluminium Electrolytic capacitors can also be manufactured for use in intermittent AC applications by using two anode foils in place of one anode ...
diagnosis and testing - Ford
diagnosis and testing - Ford

... Before Pinpoint Tests NOTE: Prior to entering pinpoint tests, check the powertrain control module (PCM) wiring harness for correct connections, bent or broken pins, corrosion, loose wires, correct routing, correct seals and their condition. Check the PCM, sensors and actuators for damage. Refer to P ...
plan check correction sheet
plan check correction sheet

... permitted in (230.2). Number of Supplies. Where more than one building or other structure is on the same property and under single management, each additional building or structure served that is on the load side of the service disconnecting means shall be supplied by one feeder or branch circuit un ...
Introduction to Technical Mathematics
Introduction to Technical Mathematics

... results, they may "list" the fuse and assign the fuse a class such as RK1, RK5, CC, or J. There are U.L. and C.S.A. standards that define the criteria that a fuse must meet to be considered belonging to a particular class. Classifications for Low Voltage Fuses - A low voltage fuse is a fuse with a v ...
< 1 ... 124 125 126 127 128 129 130 131 132 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report