• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EE369 POWER SYSTEM ANALYSIS
EE369 POWER SYSTEM ANALYSIS

An Improved Hybrid DSTATCOM Topology to Compensate Reactive
An Improved Hybrid DSTATCOM Topology to Compensate Reactive

... transistor (IGBT) switches. It leads to the increase in the cost, size, weight, and power rating of the VSI. In addition, traditional DSTATCOM topologies use an L-type interfacing filter for shaping of the VSI injected currents However; the LCL filter uses a similar dc-link voltage as that of DSTATC ...
hw2-s04 - Rensselaer Polytechnic Institute
hw2-s04 - Rensselaer Polytechnic Institute

... The above poorly designed lossless transmission line circuit has a length of 300 [m] and the velocity of propagation is 3E8 [m/s]. Assuming a 1E6 [Hz] source frequency and a 10 [V] source amplitude, determine the input voltage, Vin, and load voltage, Vl. Include a phase term relative to the source p ...
Rose LED Project
Rose LED Project

... optimum level, and thus minimizing the system power loss. At the same time, accurate current regulation for each of the 32 LED strings is maintained. The LX24232 includes an on-chip analog to digital converter for drain voltage (VD) measurements, for power supply control, fault detection and protect ...
Experiment No.7 Kirchhoff`s Laws Apparatus Theory
Experiment No.7 Kirchhoff`s Laws Apparatus Theory

... Fig.(1), where the arrows show the directions in which it is given that the currents are flowing. (The number alongside each arrow is the amount of current associated with that arrow.) ...
Intro, SI units
Intro, SI units

... • (otherwise the circuit would explode or freeze) ...
Form 6-LS Recloser Control Distribution Protection
Form 6-LS Recloser Control Distribution Protection

Homework Set 2
Homework Set 2

... The following figure shows a three phase power system with two loads. The  connected generator is producing a line voltage of 480 V, and the line impedance is 0.09+j0.16  . Load 1 is Y connected with a phase impedance of 2.536.87 o  . Load 2 is  connected with a phase impedance of 5  20o  . ...
Sheet 5
Sheet 5

... Suppose an analog-digital converter IC ("chip") inputs a voltage ranging from 0 to 5 volts DC and converts the magnitude of that voltage into an 8-bit binary number. How many discrete "steps" are there in the output as the converter circuit resolves the input voltage from one end of its range (0 vol ...
INGEPAC PQM300 flyer
INGEPAC PQM300 flyer

... INGEPACTM PQM300 is a class B grid voltage quality meter and recorder, in compliance with UNE-EN 50160 and IEC 61000-4-30 standards. These devices are a suitable tool for the control of the service voltage where an exchange of power between two grids is possible, as well as for the monitoring of sta ...
A Quasi-Resonant Soft Switching 48-pulse PWM inverter with closed
A Quasi-Resonant Soft Switching 48-pulse PWM inverter with closed

... Figure 1. The overall system simulated in MATLAB All of the above mentioned FACTS devices are based on semi-conductor switches which inevitably bring along power quality and efficiency problems. In order to improve power quality, which is doubtlessly a very important asset if not the most, multi-pu ...
PDF
PDF

... solenoid-spring operating mechanism. The recloser will be opened and closed by means of energy provided by a motor operating at 240 Vac, 60 Hz and stored in springs for both tripping and closing operations. Bushings will be of “wet” process porcelain and will have a standard creepage distance of 12" ...
ISSUE OF CONCERN
ISSUE OF CONCERN

DEHRADUN INSTITUTE OF TECHNOLOGY Assignment:-3  DEPARTMENT OF ELECTRICAL ENGINEERING
DEHRADUN INSTITUTE OF TECHNOLOGY Assignment:-3 DEPARTMENT OF ELECTRICAL ENGINEERING

... (EA1210: Transformer) ...
Editorial - Korba - World Automation Congress
Editorial - Korba - World Automation Congress

Lab 6 - La Salle University
Lab 6 - La Salle University

Combinations of Capacitors
Combinations of Capacitors

... PHYSICS 202 SPRING 06 LAB 6 ...
Electical Safety Presentation
Electical Safety Presentation

how do metal oxide varistors work
how do metal oxide varistors work

... Metal Oxide Varistor (MOV) technology is the most prevalent technology utilized in electrical transient protection products today. Many industry manufacturers, including Current Technology, integrate various sizes of radial or strap-type MOVs into their products: 20mm, 32mm and 40mm diameter MOVs ar ...
Microelectromechanical Devices
Microelectromechanical Devices

... Idealized Circuit I0 vd ...
ECE 241L_lab5_old
ECE 241L_lab5_old

... Each of the three circuits contains exactly the same elements: an inductor, a capacitor, the input voltage source (which may be a battery), a load resistance, a voltage controlled switch driven by a pulse generator and a diode. Each circuit provides a different function of voltage transformation, wh ...
universitetet i oslo
universitetet i oslo

... How large is the total voltage gain in this circuit (Av = Vut/Vinn) for low frequencies ( 1 - 10 Hz) How large is the the voltage gain – in dB - in the last opamp (U2) for low frequencies (1-10 Hz) ? These opamps have a 1 MHz Gain Bandwidth Product (GBW). At what frequency will the total voltage gai ...
Document
Document

... blink and buzzer to sound. This is the basic principle of the project. This simple circuit can detect any cellphone activities like sending or receiving calls or SMS, or any type of data transmission. ...
CIRED 2003 Barcelona
CIRED 2003 Barcelona

... tolerated. TMF interrupters also produce a significant arc voltage that is useful in this application. The short circuit current interrupting capability of vacuum interrupters has steadily increased since their introduction. Cutler-Hammer’s first vacuum interrupter in 1966 was 182 millimeters in dia ...
EET421 Exp.#2 - Portal UniMAP
EET421 Exp.#2 - Portal UniMAP

... 2) In the first part of this experiment, connect the power diode as the power converter device to a 100 Ohm resistor. After ensure your connection is correct, turn-on the power of the AC supply. 3) On ED-5306, there are 0Vac, 6Vac, 12Vac, 24Vac and 50Vac supply terminals. Please note that DON’T CHOO ...
< 1 ... 1100 1101 1102 1103 1104 1105 1106 1107 1108 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report