• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
WP1 INSTALLATION INSTRUCTIONS
WP1 INSTALLATION INSTRUCTIONS

... Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON ...
2005-2 Second Exercise: The circuit breaker in a kitchen ( 6.5 points
2005-2 Second Exercise: The circuit breaker in a kitchen ( 6.5 points

self oscillating dimmable electronic ballast
self oscillating dimmable electronic ballast

... without any sacrifice. The system is now part of the Energy Conservation program over the world and reduction of energy consumption by implementing energy conservation schemes is needed. Incandescent lamps convert just five per cent of energy into light and the remainder into heat where as fluoresce ...
Unit 3 Day 5: EMF & Terminal Voltage, & DC Resistor Circuits
Unit 3 Day 5: EMF & Terminal Voltage, & DC Resistor Circuits

COMBINED SERIES-PARALLEL CIRCUIT EXAMPLE
COMBINED SERIES-PARALLEL CIRCUIT EXAMPLE

... resistor in the combination, as expected (R345 > R3, R4, R5) The combination of parallel resistors resulted in equivalent resistances less than any single resistor in the combination, as expected. The voltage across R5 was less than the voltage supplied by the battery, as expected. ...
Measuring_Voltage_an..
Measuring_Voltage_an..

Ch 18: Electric Current Study Guide
Ch 18: Electric Current Study Guide

... 2. ______________ Electrons flow from ____ to ___ potential. 3. ______________ ____ and generators are devices that pump electrons to an object with a higher concentration of electrons than the original object. 4. ______________ Electric current is measured in ____. 5. ______________ Electron pumps ...
Ballast Basics I - Universal Lighting Technologies
Ballast Basics I - Universal Lighting Technologies

... Fluorescent lamps are significantly more efficient than incandescent lamps, using less energy and lasting significantly longer. This efficiency can be measured in terms of Lumens per Watt (LPW). This is similar to Miles per Gallon with an ...
Basic Ciruits
Basic Ciruits

... 9. If the voltage drop across the power supply is 100 Volts, and three identical resistors are connected in parallel, what’s the voltage drop about a single resistor? a. 100 V b. 0 V c. 33 1/3 V ...
SELC 2000
SELC 2000

... (including CDM) H.I.D. Lamps with a low frequency controlled power waveform. Lamps from 50 Watts to 100 Watts are catered for within the range. Full power output is maintained throughout lamp life even though the mains input voltage could dip 20V or 40V below its nominal. Conventional gear reduces p ...
PowerSpec HDF High Performance Fluorescent Dimming Ballasts
PowerSpec HDF High Performance Fluorescent Dimming Ballasts

... circuitry, surge protection, and testing/calibration. The PowerSpec HDF Ballast achieves its outstanding performance by incorporating a unique electronic feedback circuit. This circuit monitors the lamp performance and continuously corrects the current input and cathode voltage to achieve consistent ...
Ohms Law Presentation File
Ohms Law Presentation File

ECE1250F14_HW2_1p3soln
ECE1250F14_HW2_1p3soln

Fluorescent Lamp Applications
Fluorescent Lamp Applications

Written - Rose
Written - Rose

... resistance circuit. The two resistors can be combine into a since they are in series. For the parallel circuit, the current through one of the resistor is proportional to the total current. The proportionality is the equivalent resistance of the parallel resistors divided by its resistance. The equi ...
reduction of harmonics in electronic ballast using buck boost converter
reduction of harmonics in electronic ballast using buck boost converter

... lumen capacity and efficiency the consumption level is reduced to improve that high power factor LED and CFL bulbs have been introduced. The LED has more advantages with long lifetime, robustness, and small size, but in cost it was economically high and also need more concentration on heat managemen ...
ComboLight New Construction Recessed Trimless - 12V PAR36 - 6 Light
ComboLight New Construction Recessed Trimless - 12V PAR36 - 6 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
ComboLight New Construction Recessed Trimless - 12V PAR36 - 5 Light
ComboLight New Construction Recessed Trimless - 12V PAR36 - 5 Light

... meshplate assembly are all steel construction. Perforated meshplate allows for trimless installation in drywall/plaster ceilings by allowing the ceiling’s mudding compound to be applied right up to the edge of the fixture opening. Includes a beveled “knife-edge” lips to ensure a clean edge. Can acco ...
Current- Voltage Characteristics
Current- Voltage Characteristics

... Current- Voltage Characteristics Apparatus low voltage variable power supply, voltmeter, ammeter, resistor, low voltage globe Action The students measure current through and voltage across the resistor and then the globe for several voltages of the power supply. They should sketch the current as a f ...
Ohm`s Law
Ohm`s Law

Series and Parallel Circuits
Series and Parallel Circuits

14.1 Series Circuits
14.1 Series Circuits

... out when the switch is opened? Explain. 3. What happens to c circuit’s resistance as more resistors are added in series? 4. A series circuit contains a 9-volt battery and three identical bulbs. What is the voltage drop across each bulb? ...
Circuits and Circuit Diagrams
Circuits and Circuit Diagrams

ldi liniarc® direct/indirect
ldi liniarc® direct/indirect

COOPER LIGHTING - SURE-LITES Catalog # Type ®
COOPER LIGHTING - SURE-LITES Catalog # Type ®

... solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state co ...
< 1 ... 932 933 934 935 936 937 938 939 940 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.