• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Heavy Duty Truck Systems Chapter 11
Heavy Duty Truck Systems Chapter 11

... exceed the DMM’s rated capacity, a current probe can be used. Current probes are not particularly accurate. There are two types: • Current transformers – A current transformer measures AC current only. The output of a current transformer is 1mA per 1A. This means that a current flow of 100A is reduc ...
Novel sampling algorithm for dsp controlled 2 kW PFC converter
Novel sampling algorithm for dsp controlled 2 kW PFC converter

... in switching mode power supplies, such as dc–dc converters, power factor correction (PFC) converters, and high frequency PWM inverters etc. [1]–[4]. Compared to analog control [5], [6] the DSP solution can add a PFC stage to power electronics system without an extra control chip. It is recognized th ...
AN-1895 LM22671 Evaluation Board (Rev. D)
AN-1895 LM22671 Evaluation Board (Rev. D)

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
Resistance measurement
Resistance measurement

Lab #2: DC Circuits
Lab #2: DC Circuits

... straight line, showing that the resistor follows Ohm’s law. 34→ From the slope of the graph, determine the actual value of R6. Compare with the nominal range specified by the manufacturer. Note → The equation V = IR means that V must be expressed in volts, I in amperes, and R in ohms. Mixing units l ...
1 - Electrical and Computer Engineering
1 - Electrical and Computer Engineering

... frequency, DC to DC resonant converter. The goal of the design is to produce an extremely efficient, small, light weight, and cost effective DC to DC converter. These are some of the properties that are made possible by using a ZVT resonant type converter. The converter built in this project has 4 m ...
Chapter 4: Direct-Current Generators ()
Chapter 4: Direct-Current Generators ()

... • As the coil rotates, a voltage in induced between its terminals A and D [ E = Blv (B flux density, l length of the conductor, v, speed of rotation) ] • This voltage appears between the brushes, and therefore across the load • The voltage is maximum when the coil is in its horizontal position • Th ...
Floating-Gate Systems
Floating-Gate Systems

... Programming Board Interface Progr ammin g Bo ard ...
ELECTRICIAN - ELTR
ELECTRICIAN - ELTR

... ABCWUA Position Description ELECTRICIAN Status APPROVED ...
TIP42 SERIES(TIP42/42A/42B/42C) PNP Epitaxial Silicon Transistor
TIP42 SERIES(TIP42/42A/42B/42C) PNP Epitaxial Silicon Transistor

... 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ...
UC3843 - Danyk.cz
UC3843 - Danyk.cz

... Pulse-by-pulse Current Limiting ...
Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Features
Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Features

...  Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)!  Risk of burns: Depending on the operation conditions the enclosure can become very hot.  If the internal fuse blows, most probably the device is defect. In th ...
Tech Sheet - Alberta Governor Service
Tech Sheet - Alberta Governor Service

... monitoring may be configured as phase-phase or phaseneutral. Front panel push-buttons allow direct control of power circuit breakers, setpoint values, and configuration of the unit. A phase sequence detection prevents a breaker closure in case of mismatching phases. The MFR 3 is available for one (M ...
PQ_UNIT III
PQ_UNIT III

... In Fig.3.6, the first arrester is connected from the line to the neutral- ground bond at the service entrance. It limits the line voltage V1 from rising too high relative to the neutral and ground voltage at the panel. When it performs its voltage-limiting action, it provides a low impedance path fo ...
The DatasheetArchive - Datasheet Search Engine
The DatasheetArchive - Datasheet Search Engine

... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
hex buffers/drivers with open-collector high
hex buffers/drivers with open-collector high

... † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to ...
LOGO!Power 12
LOGO!Power 12

FDS4685 40V P-Channel PowerTrench MOSFET
FDS4685 40V P-Channel PowerTrench MOSFET

... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
Stray voltage
Stray voltage

... Wisconsin demonstrated that the sensing voltage, on one of the metal probes of an electronic milk flow sensor at one end of a long milk tube, had to be raised to more than 1000V to induce a cow response. Most electronic sensors use sensing voltages well below 10V. Similar studies have shown that rub ...
Caddock - Overview of Caddock`s High Performance Film Resistors
Caddock - Overview of Caddock`s High Performance Film Resistors

... Type TF Low TC Ultra-Precision Film Resistors Tolerance to 0.01% Resistance Range from 1 Kohm to 125 Megohms, Temperature Coefficient 5, 10 or 15 ppm/°C from -15°C to +105°C Type TK Military Temp Range, Precision Low TC, Radial-Lead Film Resistors Tolerance 0.1% to 0.05%, Resistance Range from 1 Koh ...
BP5062A5
BP5062A5

EEE 116-1418
EEE 116-1418

... STATCOM system has the advantages of fastspeed response to load change, accurate unbalanced load compensation, no auxiliary circuit for dc links, less on-line calculation, specific unequal dc voltage regulation, as well as certain but unequal switching frequencies. Recently, some other interesting t ...
Commonly used electrical symbols
Commonly used electrical symbols

... of communicating the components, electrical relationships, and connections within a circuit or system. Components are normally represented by universally accepted symbols. ...
Worcester Polytechnic Institute
Worcester Polytechnic Institute

Physics of pacing - Cardiac and Stroke Networks in Lancashire
Physics of pacing - Cardiac and Stroke Networks in Lancashire

< 1 ... 491 492 493 494 495 496 497 498 499 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.