• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
POWER QUALITY ANALYSIS BASED ON HARMONIC DISTORTION
POWER QUALITY ANALYSIS BASED ON HARMONIC DISTORTION

5-Channel ESD Protection Array
5-Channel ESD Protection Array

... where IESD is the ESD current pulse, and VSUPPLY is the positive supply voltage. An ESD current pulse can rise from zero to its peak value in a very short time. As an example, a level 4 contact discharge per the IEC61000−4−2 standard results in a current pulse that rises from zero to 30 Amps in 1 ns ...
NCP1251 - ONSemi
NCP1251 - ONSemi

ICE3BRxx65J(Z)(G)
ICE3BRxx65J(Z)(G)

... controller with power MOSFET and startup cell in a DIP or DSO package. The switching frequency is running at 65 KHz and it targets for DVD player, set-top box, portable game console, auxiliary power supply, etc. The ICE3BRxx65J(Z)(G) adopts the BiCMOS technology and provides a wider Vcc operating ra ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1743-1748
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1743-1748

Lecture - Dr. Imtiaz Hussain
Lecture - Dr. Imtiaz Hussain

... The DIAC is a five-layer device trigger diode that conducts current only after its breakdown voltage has been exceeded momentarily. When this occurs, the resistance of the diode abruptly decreases, leading to a sharp decrease in the voltage drop across the diode and, usually, a sharp increase in cur ...
ADP3181 - uri=media.digikey
ADP3181 - uri=media.digikey

... 6-bit VRD/VRM 10 designs, depending on the setting of the CPUID pin. Multiphase operation is important for producing the high currents and low voltages demanded by today’s microprocessors. Handling the high currents in a single-phase converter places high thermal demands on the components in the sys ...
isobar® - Parts Express
isobar® - Parts Express

... on your computer and other electronic equipment. Under low voltage conditions, your equipment's internal power supply and circuitry must compensate by working harder. Repeated exposure to brownouts can overheat these sensitive components, causing total system failure. • Localized brownouts are frequ ...
LTC6905.pdf
LTC6905.pdf

instruction manual
instruction manual

... 2.2.1.4 Used as the CV output, in general the CC adjustment (2) and (17) should be set to maximum, but for this unit, the current-limiting protection point can also be set arbitrarily. Setting procedure: turn on power, rotate counterclockwise the CC adjustment (2) and (17) to minimum, then make the ...
discrete preamplifier for apd readout
discrete preamplifier for apd readout

... The input stage is followed by a broadband (300 MHz), fast (2'000 V/μs) and low power (±1 mA) current feedback operational amplifier of the type AD8011AR from the company Analog Devices. With its typical input voltage noise density of only 2 nV/sqrt(Hz) at 10 kHz, this amplifier suits well for such ...
MAX1996A High-Efficiency, Wide Brightness Range, CCFL Backlight Controller General Description
MAX1996A High-Efficiency, Wide Brightness Range, CCFL Backlight Controller General Description

... The MAX1996A integrated controller is optimized to drive cold-cathode fluorescent lamps (CCFLs) using synchronized full-bridge inverter architecture. Synchronized drive provides near sinusoidal waveforms over the entire input range to maximize the life of CCFLs. The controller also operates over a w ...
PHY 167 - Lehman College
PHY 167 - Lehman College

Aid troubleshooting
Aid troubleshooting

... with all voltage regulators. When a system is first installed, it is recommended that the Shunt Paralleling Procedure be followed to set up the system. This will allow basic check out and performance to be accomplished. System performance across the entire speed and load range will be displayed and ...
DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV
DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV

... on SMR devices is accomplished by an external control contact which is connected to the terminals B1/B2. Activation of the timing function on SMRV devices is accomplished by an control voltage which is connected to terminal B1. After first removal of control source (contact on SMR or voltage on SMRV ...
Berechnung von Netztransienten
Berechnung von Netztransienten

... • Single phase faults in stator windings are in most cases intermittent faults. • The corresponding transient fault currents are by a factor of 60 higher than the small steady state fault current and hence responsible for damages in stator iron and winding. • High resistance grounding (most usual) o ...
pat2817708_fender.pdf
pat2817708_fender.pdf

Effects of High Switching Frequency on Buck Regulators
Effects of High Switching Frequency on Buck Regulators

MAX16955 36V, 1MHz Step-Down Controller with Low Operating Current General Description
MAX16955 36V, 1MHz Step-Down Controller with Low Operating Current General Description

... The MAX16955 is a current-mode, synchronous PWM step-down controller designed to operate with input voltages from 3.5V to 36V while using only 50μA of quiescent current at no load. The switching frequency is adjustable from 220kHz to 1MHz by an external resistor and can be synchronized to an externa ...
74VHC4040 12-Stage Binary Counter 74VHC4040  12-Sta
74VHC4040 12-Stage Binary Counter 74VHC4040 12-Sta

... The VHC4040 is an advanced high-speed CMOS device fabricated with silicon gate CMOS technology. It achieves the high-speed operation similar to equivalent Bipolar Schottky TTL while maintaining the CMOS low power dissipation. The VHC4040 is a 12-stage counter which increments on the negative edge of ...
USE OF APPROVED VOLTAGE INDICATORS
USE OF APPROVED VOLTAGE INDICATORS

... Capacitive Phasing-out Devices comprise two units – an Emitter unit and a Receiver unit. Both units are designed to be attached to Approved insulated rods and are Approved for phasing out overhead conductors only, up to and including 33kV. Neither the Emitter nor the Receiver is Approved as a Voltag ...
1-MHz 45-µA CMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIER OPA2348-Q1 OPA4348-Q1 FEATURES
1-MHz 45-µA CMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIER OPA2348-Q1 OPA4348-Q1 FEATURES

... Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absol ...
Introduction to Sensors - Universal Lighting Technologies
Introduction to Sensors - Universal Lighting Technologies

... Power Pack • Provides class 2 control power to one or more sensors • Has an integral relay to control the lighting load ...
Conquering the Multi Kilowatt Source/Sink Test
Conquering the Multi Kilowatt Source/Sink Test

... A BSS is predominantly a voltage device; both the DC source and the electronic load normally operate in constant voltage (CV) mode. Their voltage is offset to provide a deadband so that they do not overlap in operation, with the electronic load’s voltage being set slightly greater than that of the D ...
G = 0.2, Level Translation, 16-Bit ADC Driver AD8275
G = 0.2, Level Translation, 16-Bit ADC Driver AD8275

... GENERAL DESCRIPTION ...
< 1 ... 300 301 302 303 304 305 306 307 308 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.