• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Atmel ATA6628/ATA6630 LIN Bus Transceiver with 3.3V (5V) Regulator and Watchdog Features
Atmel ATA6628/ATA6630 LIN Bus Transceiver with 3.3V (5V) Regulator and Watchdog Features

... The internal 3.3V/5V voltage regulator is capable of driving loads up to 85mA. It is able to supply the microcontroller and other ICs on the PCB and is protected against overloads by means of current limitation and overtemperature shut-down. Furthermore, the output voltage is monitored and will caus ...
Enabling Low-Distortion Varactors for Adaptive Transmitters , Student Member, IEEE , Fellow, IEEE
Enabling Low-Distortion Varactors for Adaptive Transmitters , Student Member, IEEE , Fellow, IEEE

UNIVERSITY OF ÇUKUROVA INSTITUTE OF NATURAL AND
UNIVERSITY OF ÇUKUROVA INSTITUTE OF NATURAL AND

... A power quality problem is any voltage, current deviations that results in failure or misoperation of customer equipment. There are two classes of power quality problems according to causes. The first class covers voltage sags/swells and momentary interruptions mostly caused by faults in the power s ...
DATA  SHEET For a complete data sheet, please also download:
DATA SHEET For a complete data sheet, please also download:

... multiplexers/demultiplexers with three select inputs (S0 to S2), two enable inputs (E1 and E2), a latch enable input (LE), eight independent inputs/outputs (Y0 to Y7) and a common input/output (Z). ...
RevG_158_Attach
RevG_158_Attach

... A(NF) designates ac equipment intended for use on aircraft electrical systems where the primary power is from narrow variable frequency (360 to 650 Hz) ac system. A(WF) designates ac equipment intended for use on aircraft electrical systems where the primary power is from wide variable frequency (36 ...
66xxA Series Operating Guide
66xxA Series Operating Guide

Application Note DrBlade™ 2 Selection of Boot Capacitor Value
Application Note DrBlade™ 2 Selection of Boot Capacitor Value

Power Plant “Horror Stories” - Beckwith Electric Co., Inc.
Power Plant “Horror Stories” - Beckwith Electric Co., Inc.

... detected quickly on large generators, this condition can trigger a system voltage collapse. If the excitation current is reduced or lost, the generator absorbs reactive power from the power system, rather than supplying it, and it operates in the underexcited region of the capability curve. If a tot ...
- IEEE Mentor
- IEEE Mentor

... projects, offshore platforms for drilling and production of energy sources, and other remote sites requiring continuous electric energy. The size of the individual generators may range from a few hundred kilowatts up to several megawatts depending on the system demand. The prime movers are typically ...
document
document

... The human touch imitator controls and sets resistance values of the controlled resistors in SCN through channels connected between SCN and it according to screen coordinates of the touch point given by the testbench. Since the moving speed of the touch point is limited to 50 points/s, the imitator i ...
V-Contact VSC Installation and service instructions 7.2/12 kV
V-Contact VSC Installation and service instructions 7.2/12 kV

... (1) This value refers to a discharged capacitor. (2) The value drops to 8 A for voltage values between 24...30V ...
1 - Monash University Research Repository
1 - Monash University Research Repository

... Figure 3.8: Shunt active power filter, (a) System configuration (b) Per phase equivalent circuit Figure 3.9: Series active power filter, (a) System configuration (b) Per phase equivalent circuit Figure 3.10: Shunt hybrid parallel topology with shunt active and shunt ...
AN84 - Linear Technology Magazine Circuit Collection, Volume IV
AN84 - Linear Technology Magazine Circuit Collection, Volume IV

... and to track it up to a maximum of fMAX = 2 • fMIN. A logic signal may also be coupled to PLL LPF to effect a 2:1 frequency shift, provided that the initial frequency has been set to less than 200kHz. ...
Datasheet
Datasheet

PECL Clocks and Termination
PECL Clocks and Termination

... ECL was chosen to operate from ground to a negative supply. Therefore the device leads with the most transients is connected into the ground plane. This resulted in the logic levels which are referenced to ground and became somewhat independent of power supply voltage. Application Note 806 ...
august 1976 - About Rattrig.com
august 1976 - About Rattrig.com

... HIGH VOLTAGE is used in the operation of this equipment. ...
VI Chip® Remote Sense PRM Evaluation Board
VI Chip® Remote Sense PRM Evaluation Board

... This board is designed to accomodate different types of PRMs. Therefore, certain circuitry on the board is not populated and there are additional considerations for using Remote Sense only PRMs. The Remote Sense PRM Evaluation Board does not operate in default switch S10 setting which has all switch ...
Fuse Characteristics, Terms and
Fuse Characteristics, Terms and

Insulation monitoring Vigilohm Merlin Gerin
Insulation monitoring Vigilohm Merlin Gerin

Electrical Safety Rules
Electrical Safety Rules

Aalborg Universitet Design and Control of an Inverter for Photovoltaic Applications
Aalborg Universitet Design and Control of an Inverter for Photovoltaic Applications

A Current Folded Down Conversion Mixer in 0.18µ CMOS Vincent
A Current Folded Down Conversion Mixer in 0.18µ CMOS Vincent

... 3.0 Mixer Theory 3.1 Introduction Mixers are essential to most communications systems as they perform the necessary frequency translation of signals. Most information signals travel at frequencies much larger than that of human speech or digital data in order to maximize bandwidth and minimize prop ...
3 Assignments using Workboard 12-200-B
3 Assignments using Workboard 12-200-B

... Both the 1N4007 and the power diode are made of Silicon and the forward conduction voltage of about 0.6 V is typical of silicon junctions. Also typical of silicon diodes is the very small reverse current. The power diode passes a greater reverse current than 1N4007. This is because it is designed fo ...
Evaluates:  MAX3869 MAX3869 Evaluation Kit General Description Features
Evaluates: MAX3869 MAX3869 Evaluation Kit General Description Features

Aalborg Universitet Real Power Shift
Aalborg Universitet Real Power Shift

... perturbations are injected at predefined intervals even though it is unnecessary during most operating conditions. Also, if islanding occurs during an interval, then it has to wait for next perturbation to be applied before it can be detected, which further elongates the detection time. Applications ...
< 1 ... 12 13 14 15 16 17 18 19 20 ... 947 >

Electrical ballast



An electrical ballast is a device intended to limit the amount of current in an electric circuit. A familiar and widely used example is the inductive ballast used in fluorescent lamps, to limit the current through the tube, which would otherwise rise to destructive levels due to the tube's negative resistance characteristic.Ballasts vary in design complexity. They can be as simple as a series resistor or inductor, capacitors, or a combination thereof or as complex as electronic ballasts used with fluorescent lamps and high-intensity discharge lamps.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report