60708-124 LARGE PTO -WInpower
... The WINPOWER PTO drive generator will provide, depending on the unit purchased, 120/240V single phase, 120/240V three phase, 120/208 three phase or 277/480 three phase 60Hz electrical service when direct-driven. Tractor or vehicle power take-off shafts, can be used for driving these generators. NOTE ...
... The WINPOWER PTO drive generator will provide, depending on the unit purchased, 120/240V single phase, 120/240V three phase, 120/208 three phase or 277/480 three phase 60Hz electrical service when direct-driven. Tractor or vehicle power take-off shafts, can be used for driving these generators. NOTE ...
Submersible Motors - Stallion Equipment
... thrust. This creates upward thrust on the motor upthrust bearing. This is an acceptable operation for short periods at each start, but running continuously with upthrust may cause excessive wear on the upthrust bearing. With certain restrictions, motors are also suitable for operations in positions ...
... thrust. This creates upward thrust on the motor upthrust bearing. This is an acceptable operation for short periods at each start, but running continuously with upthrust may cause excessive wear on the upthrust bearing. With certain restrictions, motors are also suitable for operations in positions ...
First Principles of a Gas Discharge Tube (GDT) Primary
... solution. The document uses Franklin’s experiment to harness the energy of a lightning storm. The kite was tied to an insulated post where the metallic string going to the kite was connected to a brass ball on the post. A second brass ball was grounded with a 2-inch gap between it and the isolated b ...
... solution. The document uses Franklin’s experiment to harness the energy of a lightning storm. The kite was tied to an insulated post where the metallic string going to the kite was connected to a brass ball on the post. A second brass ball was grounded with a 2-inch gap between it and the isolated b ...
DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
... Note 2: VSS e 0V unless otherwise specified. Note 3: These devices should not be connected to circuits with the power ‘‘ON’’. Note 4: In all cases, there is approximately 5 pF of probe and jig capacitance in the output; however, this capacitance is included in CL wherever it is specified. Note 5: VI ...
... Note 2: VSS e 0V unless otherwise specified. Note 3: These devices should not be connected to circuits with the power ‘‘ON’’. Note 4: In all cases, there is approximately 5 pF of probe and jig capacitance in the output; however, this capacitance is included in CL wherever it is specified. Note 5: VI ...
CE/SC 12
... 12-07 Present state and trends in developing tap changers of the high speed transition resistor type with special regard to operating reliability. 12-08 On load tap changers. Important new developments for improved reliability. Increased ratings and important application problems. 12-09 Criteria for ...
... 12-07 Present state and trends in developing tap changers of the high speed transition resistor type with special regard to operating reliability. 12-08 On load tap changers. Important new developments for improved reliability. Increased ratings and important application problems. 12-09 Criteria for ...
General Description Features
... The MAX6715A–MAX6729A/MAX6797A are ultra-low-voltage microprocessor (μP) supervisory circuits designed to monitor two or three system power-supply voltages. These devices assert a system reset if any monitored supply falls below its factory-trimmed or adjustable threshold and maintain reset for a mi ...
... The MAX6715A–MAX6729A/MAX6797A are ultra-low-voltage microprocessor (μP) supervisory circuits designed to monitor two or three system power-supply voltages. These devices assert a system reset if any monitored supply falls below its factory-trimmed or adjustable threshold and maintain reset for a mi ...
MCP6V61/MCP6V61U Data Sheet
... Current at Output and Supply Pins ...................................................................................................................... ±30 mA Storage Temperature ........................................................................................................................ ...
... Current at Output and Supply Pins ...................................................................................................................... ±30 mA Storage Temperature ........................................................................................................................ ...
Brushless DC Motor Control Made Easy
... the current to the motor will be a series of high current pulses instead of the desired average of the voltage waveform. Averaging is easier to attain at lower frequencies if the parasitic motor inductance is relatively high, but high inductance is an undesirable motor characteristic. The ideal freq ...
... the current to the motor will be a series of high current pulses instead of the desired average of the voltage waveform. Averaging is easier to attain at lower frequencies if the parasitic motor inductance is relatively high, but high inductance is an undesirable motor characteristic. The ideal freq ...
[UPS]. - Alpha Technologies Ltd
... Alpha Technologies warrants its equipment to be free of manufacturing defects in material and workmanship for a period of 24 months from the date of manufacture. The liability of Alpha Technologies under this warranty is solely limited to repairing, replacing, or issuing credit for such equipment (a ...
... Alpha Technologies warrants its equipment to be free of manufacturing defects in material and workmanship for a period of 24 months from the date of manufacture. The liability of Alpha Technologies under this warranty is solely limited to repairing, replacing, or issuing credit for such equipment (a ...
User Manual - Sonel Analysis
... blue - current configuration is compatible with the analyzer, but differs from the one saved to the disk, yellow - the configuration is not compatible with the analyzer, but is compatible with the one saved to disk, red - the current configuration is not compatible with the analyzer and not co ...
... blue - current configuration is compatible with the analyzer, but differs from the one saved to the disk, yellow - the configuration is not compatible with the analyzer, but is compatible with the one saved to disk, red - the current configuration is not compatible with the analyzer and not co ...
- IEEE Mentor
... projects, offshore platforms for drilling and production of energy sources, and other remote sites requiring continuous electric energy. The size of the individual generators may range from a few hundred kilowatts up to several megawatts depending on the system demand. The prime movers are typically ...
... projects, offshore platforms for drilling and production of energy sources, and other remote sites requiring continuous electric energy. The size of the individual generators may range from a few hundred kilowatts up to several megawatts depending on the system demand. The prime movers are typically ...
NBSG16M - 2.5 V/3.3 V Multilevel Input to CML Clock/Data Receiver
... LVCMOS, CML, or LVDS. The CML output structure contains internal 50 W source termination resistor to VCC. The device generates 400 mV output amplitude with 50 W receiver resistor to VCC. The VBB pin is internally generated voltage supply available to this device only. For all single-ended input cond ...
... LVCMOS, CML, or LVDS. The CML output structure contains internal 50 W source termination resistor to VCC. The device generates 400 mV output amplitude with 50 W receiver resistor to VCC. The VBB pin is internally generated voltage supply available to this device only. For all single-ended input cond ...
Alpha Continuity: 6K / 10K
... The material contained in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Alpha Technologies assumes no liability resulting from errors or omissions in this document, or ...
... The material contained in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Alpha Technologies assumes no liability resulting from errors or omissions in this document, or ...
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST
... the prime mover. This PTO drive generator will provide, 120/ 240V single phase, 60Hz electrical service when properly driven. NOTE: The prime mover which drives the generator must be capable of delivering approximately 2 HP per 1000 watts output from the generator. Observe input RPM specifications. ...
... the prime mover. This PTO drive generator will provide, 120/ 240V single phase, 60Hz electrical service when properly driven. NOTE: The prime mover which drives the generator must be capable of delivering approximately 2 HP per 1000 watts output from the generator. Observe input RPM specifications. ...
MOSFET CURRENT SOURCE GATE DRIVERS AND VOLTAGE REGULATOR MODULES
... proposed in this thesis. The first contribution is an accurate analytical loss model of a power MOSFET with a Current-Source Driver (CSD). The impact of the parasitic components is investigated. Based on the proposed loss model, a general method to optimize the CSD is presented. With the proposed op ...
... proposed in this thesis. The first contribution is an accurate analytical loss model of a power MOSFET with a Current-Source Driver (CSD). The impact of the parasitic components is investigated. Based on the proposed loss model, a general method to optimize the CSD is presented. With the proposed op ...
Negative Rail Input, Rail-to-Rail Out, Precision, 850
... Specifications are from the input Vocm pin to the differential output average voltage. This slew rate is the average of the rising and falling time estimated from the large-signal bandwidth as: (VP / √2) · 2π · f–3dB. Input offset voltage drift, input bias current drift, input offset current drift, ...
... Specifications are from the input Vocm pin to the differential output average voltage. This slew rate is the average of the rising and falling time estimated from the large-signal bandwidth as: (VP / √2) · 2π · f–3dB. Input offset voltage drift, input bias current drift, input offset current drift, ...
- White Rose eTheses Online
... For the MPPT algorithm to work effectively, precise voltage and current measurements must be obtained from PV panel which can be difficult to achieve in a practical system due to measurement noise. This thesis therefore examines the effect of this noise on the performance of the MPPT algorithm and p ...
... For the MPPT algorithm to work effectively, precise voltage and current measurements must be obtained from PV panel which can be difficult to achieve in a practical system due to measurement noise. This thesis therefore examines the effect of this noise on the performance of the MPPT algorithm and p ...
CE/SC 12
... 12-07 Present state and trends in developing tap changers of the high speed transition resistor type with special regard to operating reliability. 12-08 On load tap changers. Important new developments for improved reliability. Increased ratings and important application problems. 12-09 Criteria for ...
... 12-07 Present state and trends in developing tap changers of the high speed transition resistor type with special regard to operating reliability. 12-08 On load tap changers. Important new developments for improved reliability. Increased ratings and important application problems. 12-09 Criteria for ...
A Better Antenna Balun
... The horizontal line near the bottom of the chart is the upper bound of the current balun’s operating region, showing that the current balun is effective when R2 < 0.1 |ZW|, irrespective of the value of R1. (Although the current balun is able to drive highimpedance loads that are situated near the X- ...
... The horizontal line near the bottom of the chart is the upper bound of the current balun’s operating region, showing that the current balun is effective when R2 < 0.1 |ZW|, irrespective of the value of R1. (Although the current balun is able to drive highimpedance loads that are situated near the X- ...
Power inverter
A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC).The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source.A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry.Static inverters do not use moving parts in the conversion process.