• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Standards of Power Quality with reference to the Code of Practice for
Standards of Power Quality with reference to the Code of Practice for

... where Ih is the rms current of the hth harmonic current, and I1 is the rms value of the fundamental current. A typical supply voltage waveform at a consumer’s metering point (or point of common coupling) normally doesn’t exceed 5% THD in Hong Kong but for some high-rise commercial buildings, the vo ...
Power Transformer Attenuates Harmonics
Power Transformer Attenuates Harmonics

... We must look elsewhere for the source, not to the generation of power. The harmonics Fig. 2. Waveforms showing harmonics typical generated downin switching devices. stream can find their way back onto the utility lines and affect all power users on the system, and ultimately adversely affect the ope ...
Calibrating voltage input signal conditioners using the Fluke 787
Calibrating voltage input signal conditioners using the Fluke 787

... mA and 4-20 mA outputs are notori2 + 3.50 = 3.75, or one-half the ous for zero and span control interacdifference between the reading tion. If, when performing step 6 in and the desired value.) the calibrating section on page 2, 2. Set the source current of the your output meter displayed a value Fl ...
Datasheet - IKCM10B60HA
Datasheet - IKCM10B60HA

... rectifier  Rugged SOI gate driver technology with stability against transient and negative voltage  Allowable negative VS potential up to -11V for signal transmission at VBS=15V  Integrated bootstrap functionality  Over current shutdown  Under-voltage lockout at all channels  Low side common e ...
Document
Document

analysis of the interleaved isolated boost
analysis of the interleaved isolated boost

... In this paper, a detailed steady-state analysis of the IBCI has been presented. This allowed the definition of a noniterative design procedure where all circuit parameters can be sized moving from a reduced set of specifications. Incidentally, the structural equivalence of the IBCI and the SAB has b ...
EXPERIMENT 3. SINGLE TUNED AMPLIFIERS Introduction
EXPERIMENT 3. SINGLE TUNED AMPLIFIERS Introduction

... small bandwidth, small gain bandwidth product, and do not provide flatten response. On the other hand, their alignment is more straightforward than double tuned amplifiers. ...
Advanced Control Architectures for Intelligent MicroGrids, Part I
Advanced Control Architectures for Intelligent MicroGrids, Part I

... could be operated without the use of phase-locked loops (PLLs), and that total load real- and reactive-power could be shared based on the converter ratings. Subsequent work [3], [4] extended the droop concept to ensure sharing of harmonic currents of non-linear loads. This was done by extending the ...
File - Senior Design
File - Senior Design

... a digital multimeter After these subsystems were finalized a prototype system was constructed. ...
maximum power point tracking of pv arrays under partial
maximum power point tracking of pv arrays under partial

... There exists a variety of maximum power point tracking (MPPT) techniques, each having its own merits and demerits. Under partialshading conditions, the conventional tracking techniques fail to guarantee successful tracking of the global maximum power, ie the conventional MPPT methods such as perturb ...
RFVC1831 数据资料DataSheet下载
RFVC1831 数据资料DataSheet下载

... RFMD. RFMD reserves the right to change component circuitry, recommended application circuitry and specifications at any time without prior notice. RFMD Green: RoHS compliant per EU Directive 2002/95/EC, halogen free per IEC 61249-2-21, < 1000ppm each of antimony trioxide in polymeric materials and ...
LM217, LM317 1.2 V to 37 V adjustable voltage regulators Description -
LM217, LM317 1.2 V to 37 V adjustable voltage regulators Description -

... programmable regulators are easily obtainable and, by connecting a fixed resistor between the adjustment and output, the device can be used as a precision current regulator. In order to optimize the load regulation, the current set resistor R1 (see Figure 6) should be tied as close as possible to th ...
5.0 TYPES OF ELECTRICAL CIRCUITS Note: The following
5.0 TYPES OF ELECTRICAL CIRCUITS Note: The following

... 5.3.7 Disadvantages of parallel lighting circuits. Some of the major disadvantages of parallel circuits for aerodrome lighting are: (a) The intensity of the lights decreases with line drop along the circuit. This may be misinterpreted if it is noticeable in a pattern of lights; (b) Two conductors ar ...
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I
Aalborg Universitet Advanced Control Architectures for Intelligent MicroGrids, Part I

1.2 V to 37 V adjustable voltage regulators
1.2 V to 37 V adjustable voltage regulators

... programmable regulators are easily obtainable and, by connecting a fixed resistor between the adjustment and output, the device can be used as a precision current regulator. In order to optimize the load regulation, the current set resistor R1 (see Figure 6) should be tied as close as possible to th ...
Instantaneous Active and Reactive Power and Current Strategies for
Instantaneous Active and Reactive Power and Current Strategies for

BFR740L3RH Maximum RF Input Power
BFR740L3RH Maximum RF Input Power

Encoders Frequently Asked Questions
Encoders Frequently Asked Questions

A - University of Wisconsin
A - University of Wisconsin

DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV
DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV

... on SMR devices is accomplished by an external control contact which is connected to the terminals B1/B2. Activation of the timing function on SMRV devices is accomplished by an control voltage which is connected to terminal B1. After first removal of control source (contact on SMR or voltage on SMRV ...
X-ray Tube Operating Range
X-ray Tube Operating Range

CAT4237EVAL2EVB CAT4237 High Voltage White LED Driver Evaluation Board User's Manual
CAT4237EVAL2EVB CAT4237 High Voltage White LED Driver Evaluation Board User's Manual

... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ...
Advances in Natural and Applied Sciences
Advances in Natural and Applied Sciences

... Opertation of negative output relift converter: The NOSLC is a new series of DC-DC converters possessing high-voltage transfer gain, high power Density, high efficiency, reduced ripple voltage and current (Fanglin luo 2003). The relift circuit performs the voltage lift in a higher way compared to th ...
difference amplifiers with a rejection factor greater than one
difference amplifiers with a rejection factor greater than one

... (this can be achieved in various ways). The mentioned value 2 X 104 is in most cases amply sufficient. A measurement problem that arose some time ago nevertheless prompted us to study the question whether difference amplifiers could be developed with an even higher rejection factor. The problem conc ...
Advances in Natural and Applied Sciences
Advances in Natural and Applied Sciences

... pre-determined locations in the s-plane. This method has been used in electric power system for different purposes (El-Sherbiny et al., 1996; Bettayeb and Randhawa, 1999; Lin and Wu, 2011; Li et al., 2012; Mahmud et al., 2014; Schuler et al., 2014). Paper (Mahmud et al., 2014) presents an approach t ...
< 1 ... 714 715 716 717 718 719 720 721 722 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report