Sigma-7 Series AC Servo Drive - Yaskawa
... There is a risk of electric shock. • Observe the precautions and instructions for wiring and trial operation precisely as described in this document. Failures caused by incorrect wiring or incorrect voltage application in the brake circuit may cause the SERVOPACK to fail, damage the equipment, or ca ...
... There is a risk of electric shock. • Observe the precautions and instructions for wiring and trial operation precisely as described in this document. Failures caused by incorrect wiring or incorrect voltage application in the brake circuit may cause the SERVOPACK to fail, damage the equipment, or ca ...
99 User manual v2
... FT-1000) or PROCESSOR OUT (TS-940, TS-950). On SSB, when speech processing is not, adjust the MIC or MIKE controls. 2. The ALPHA 99 “faults” into STBY or OFF when unsafe operating conditions occur. If this occurs, the fault will clear after 30 seconds and if you are certain that you have taken care ...
... FT-1000) or PROCESSOR OUT (TS-940, TS-950). On SSB, when speech processing is not, adjust the MIC or MIKE controls. 2. The ALPHA 99 “faults” into STBY or OFF when unsafe operating conditions occur. If this occurs, the fault will clear after 30 seconds and if you are certain that you have taken care ...
User`s Guide
... 1.Turning on the instrument: Press the power key on the front panel to turn on the power. After displaying “WELCOME” for 2 seconds and model number such as “PROTEK 9340” for 1 second in flashing manner. The instrument will enter into “standard waveforms” function state according the turning-on setti ...
... 1.Turning on the instrument: Press the power key on the front panel to turn on the power. After displaying “WELCOME” for 2 seconds and model number such as “PROTEK 9340” for 1 second in flashing manner. The instrument will enter into “standard waveforms” function state according the turning-on setti ...
7 Series FPGAs PCB Design and Pin Planning Guide
... substrate material (usually FR4, an epoxy/glass composite) with copper plating on both sides has portions of copper etched away to form conductive paths. Layers of plated and etched substrates are glued together in a stack with additional insulator substrates between the etched substrates. Holes are ...
... substrate material (usually FR4, an epoxy/glass composite) with copper plating on both sides has portions of copper etched away to form conductive paths. Layers of plated and etched substrates are glued together in a stack with additional insulator substrates between the etched substrates. Holes are ...
User Manual
... - EN-IEC 62040-1. Uninterruptible power supply (UPS). Part 1-1: General and safety requirements for UPS devices in use in accessible areas by end users. - EN-IEC 60950-1. IT equipment. Safety. Part 1: General requirements. - EN-IEC 62040-2. Uninterruptible power supply (UPS). Part 2: Requirements fo ...
... - EN-IEC 62040-1. Uninterruptible power supply (UPS). Part 1-1: General and safety requirements for UPS devices in use in accessible areas by end users. - EN-IEC 60950-1. IT equipment. Safety. Part 1: General requirements. - EN-IEC 62040-2. Uninterruptible power supply (UPS). Part 2: Requirements fo ...
PDF
... analyzed in [21–27], which is able to effectively obtain PFC while producing high-quality waveforms and complying to regulations on low- and high-frequency distortions of the mains ac power lines. The topology is shown in Figure 1 and is the subject of this paper. It consists of a quasi-lossless syn ...
... analyzed in [21–27], which is able to effectively obtain PFC while producing high-quality waveforms and complying to regulations on low- and high-frequency distortions of the mains ac power lines. The topology is shown in Figure 1 and is the subject of this paper. It consists of a quasi-lossless syn ...
LTM4608A - Low VIN, 8A DC/DC uModule with Tracking, Margining, and Frequency Synchronization
... voltage exits a ±10% window around the regulation point. ...
... voltage exits a ±10% window around the regulation point. ...
AF-300 E11 - GE Industrial Solutions
... induction motor. It should not be used for singlephase motors or other purposes, otherwise fire could occur. ...
... induction motor. It should not be used for singlephase motors or other purposes, otherwise fire could occur. ...
ppt - kaliasgoldmedal
... Different types of Line Commutated Converters • AC to DC Converters (Phase controlled rectifiers) • AC to AC converters (AC voltage controllers) • AC to AC converters (Cyclo converters) at low output frequency. ...
... Different types of Line Commutated Converters • AC to DC Converters (Phase controlled rectifiers) • AC to AC converters (AC voltage controllers) • AC to AC converters (Cyclo converters) at low output frequency. ...
0.5μm InP DHBT Technology for 100GHz+ Mixed Signal Integrated
... spectrum analyzer. V-band or W-band harmonic mixer modules were used on the divider output when testing above 100GHz or 150GHz.The maximum clock rates achievable for the static frequency and dynamic frequency dividers were 114GHz and 170GHz, respectively. The maximum simulated toggle rates of the di ...
... spectrum analyzer. V-band or W-band harmonic mixer modules were used on the divider output when testing above 100GHz or 150GHz.The maximum clock rates achievable for the static frequency and dynamic frequency dividers were 114GHz and 170GHz, respectively. The maximum simulated toggle rates of the di ...
ZXMS6005DG Product Summary Features and Benefits
... 7. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipation ...
... 7. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipation ...
DRV8880 - Texas Instruments
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absol ...
Quad IEEE 802.3at Power-Over-Ethernet Controller (Rev. B)
... Std 802.3at-2009 (or 802.3at) for Power Sourcing Equipment (PSE). The PSE controller can detect Powered devices (PDs) that have a valid signature, determine the power requirements of the devices according to the classification, and apply power to the devices, limited per 802.3at. Based on an industr ...
... Std 802.3at-2009 (or 802.3at) for Power Sourcing Equipment (PSE). The PSE controller can detect Powered devices (PDs) that have a valid signature, determine the power requirements of the devices according to the classification, and apply power to the devices, limited per 802.3at. Based on an industr ...
MP28164 - Monolithic Power System
... in the secondary period) and an offset voltage is added to the current ramp signal to allow it to reach VC-Buck. SWC turns off when the current ramp signal intersects with VC-Boost in the secondary period, and SWD conducts the inductor current when SWC is off. This is called boost operation. SWA tur ...
... in the secondary period) and an offset voltage is added to the current ramp signal to allow it to reach VC-Buck. SWC turns off when the current ramp signal intersects with VC-Boost in the secondary period, and SWD conducts the inductor current when SWC is off. This is called boost operation. SWA tur ...
Power supplies and transformers Phaseo Creator of energy from 0.3
... deliver a voltage which is precise to 3%, whatever the load and whatever the type of mains supply, within a range of 85 to 264 V for single-phase, or 360 to 550 V for 3-phase. Conforming to IEC standards and UL and CSA certified, they are suitable for universal use. The inclusion of overload and sho ...
... deliver a voltage which is precise to 3%, whatever the load and whatever the type of mains supply, within a range of 85 to 264 V for single-phase, or 360 to 550 V for 3-phase. Conforming to IEC standards and UL and CSA certified, they are suitable for universal use. The inclusion of overload and sho ...
6.2.5 Capacitors
... measured in _______________________. A 1-farad capacitor connected to a 1 volt supply will store 6,280,000,000,000,000,000 (6.28 x 10 18) electrons! Most capacitors have much smaller values. Small capacitors are specified in ______________________ (trillionths of a farad) and larger capacitors are m ...
... measured in _______________________. A 1-farad capacitor connected to a 1 volt supply will store 6,280,000,000,000,000,000 (6.28 x 10 18) electrons! Most capacitors have much smaller values. Small capacitors are specified in ______________________ (trillionths of a farad) and larger capacitors are m ...
HARDWARE MANUAL FX SERIES PROGRAMMABLE CONTROLLERS
... This unit may be used as supplied and will be in compliance with the previously identified standards / directives.However, it is recommended as an additional precaution to reduce conducted mains terminal voltage emissions when power sources are shared, that an external mains filter is used. Mitsubis ...
... This unit may be used as supplied and will be in compliance with the previously identified standards / directives.However, it is recommended as an additional precaution to reduce conducted mains terminal voltage emissions when power sources are shared, that an external mains filter is used. Mitsubis ...
6.2.5 Capacitors
... measured in _______________________. A 1-farad capacitor connected to a 1 volt supply will store 6,280,000,000,000,000,000 (6.28 x 10 18) electrons! Most capacitors have much smaller values. Small capacitors are specified in ______________________ (trillionths of a farad) and larger capacitors are m ...
... measured in _______________________. A 1-farad capacitor connected to a 1 volt supply will store 6,280,000,000,000,000,000 (6.28 x 10 18) electrons! Most capacitors have much smaller values. Small capacitors are specified in ______________________ (trillionths of a farad) and larger capacitors are m ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
... 12(1) A current transformer used in a protection system must be either magnetic or optical, and must not be the limiting element in the transmission facility’s rating. (2) The maximum available current transformer ratio must be sized for the ultimate fault level of the facility as set out in the fun ...
... 12(1) A current transformer used in a protection system must be either magnetic or optical, and must not be the limiting element in the transmission facility’s rating. (2) The maximum available current transformer ratio must be sized for the ultimate fault level of the facility as set out in the fun ...
International
... firmly connected to the electrical ground at the power outlet. Any interruption of the protective ground conductor or disconnection of the protective earth terminal may cause a potential shock hazard that could result in personal injury. Only use provided input AC cord set or one with equivalent rat ...
... firmly connected to the electrical ground at the power outlet. Any interruption of the protective ground conductor or disconnection of the protective earth terminal may cause a potential shock hazard that could result in personal injury. Only use provided input AC cord set or one with equivalent rat ...