• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
3.0 electrical specifications
3.0 electrical specifications

1500 Data Sheet
1500 Data Sheet

... near pumps, motors or other operating equipment, the Series 1500 Induction Relay permits use of low-cost light gauge wires for the control circuit to level sensing electrodes. Relays with low voltage secondary coils provide remote control up to 36,000 feet from contact type pilot devices. Available ...
FPF2174 IntelliMAX™ Advanced Load Management Products FP F2
FPF2174 IntelliMAX™ Advanced Load Management Products FP F2

... between VIN and GND. A 4.7 F ceramic capacitor, CIN, placed close to the pins is usually sufficient. Higher values of C IN can be used to further reduce the voltage drop. ...
Motor Control Centers - A117 North American IC Catalog
Motor Control Centers - A117 North American IC Catalog

SP-35XMV DC Ammeter for Battery Powered Systems 3 1/2 Digit 0.48” LCD
SP-35XMV DC Ammeter for Battery Powered Systems 3 1/2 Digit 0.48” LCD

... The SP-35XMV, when used with its companion meter SP-35X, is an elegant solution to the problem of measuring and displaying voltage and current in DC powered systems. To simplify the installation when used together, specify the stackable case option to mount both meters in a single cutout. Our custom ...
Stability analysis of low-dropout linear
Stability analysis of low-dropout linear

... the load current through the regulator (IB = IC /β). This results in a “quiescent” current that is proportional to load current—wasting more power at high loads. Another disadvantage associated with a PNP pass transistor is its tendency to saturate when the device goes into dropout. The resulting dr ...
ECGR 2255 Lab Write-Ups
ECGR 2255 Lab Write-Ups

s lec e - pSenso
s lec e - pSenso

... between power source and supply terminals to facilitate power 'ON' or ‘OFF’ function. However this switch or breaker must be installed in a convenient position normally accessible to the operator. 4. Before disconnecting the secondary of the external current transformer from the equipment, make sure ...
section 16920-1 - OPS Schneider Electric
section 16920-1 - OPS Schneider Electric

... 10) Max current demand, per auxiliary phase 11) Maximum auxiliary power total demand 12) Maximum current value, per phase 13) Global alarm counters, for each latching alarm type 14) Energy values, per branch 15) Max power demand, per branch 16) Max current demand, per branch 17) Max total power, per ...
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER

... Lee Nuclear Station Units 1 and 2 are located in the eastern portion of Cherokee County in north central South Carolina, approximately 35 miles southwest of Charlotte, North Carolina, approximately 25 miles northeast of Spartanburg, South Carolina and approximately 7.5 miles southeast of Gaffney, So ...
AP6503A Description Pin Assignments
AP6503A Description Pin Assignments

... The AP6503A has on-chip thermal protection that prevents damage to the IC when the die temperature exceeds safe margins. It implements a thermal sensing to monitor the operating junction temperature of the IC. Once the die temperature rises to approximately 160°C, the thermal protection feature gets ...
Powering Trends and Issues for IP Telephony over CATV
Powering Trends and Issues for IP Telephony over CATV

... the duration of standby operation, both for network devices such as the optical node, amplifiers, line extenders, and other active devices, and also for the NIUs; (2) a method of powering is needed for the NIUs located at the residence of each telephony customer. Presently with circuit-switched tele ...
Energy Harvesting Devices for High Voltage Transmission Line
Energy Harvesting Devices for High Voltage Transmission Line

... power grid. The solution is to build a real time monitoring system for transmission line maintenance [10-16]. Recently, with the demand for a “Smart Grid”, the new transmission lines planned for the next two decades have made the real time monitoring related research more urgent and meaningful [17]. ...
8. Protected Low Side Drivers - Bridging Theory into Practice
8. Protected Low Side Drivers - Bridging Theory into Practice

SUM 1001
SUM 1001

AD711 Precision, Low Cost, High Speed, BiFET Op Amp (Rev.E)
AD711 Precision, Low Cost, High Speed, BiFET Op Amp (Rev.E)

... individual circuit components; in addition, a careful tradeoff was made: the gain bandwidth product (4 MHz) and slew rate (20 V/ms) were chosen to be high enough to provide very fast settling time but not too high to cause a significant reduction in phase margin (and therefore stability). Thus desig ...
BD63940EFV
BD63940EFV

... Connecting of the power supply in reverse polarity can damage IC. Take precautions when connecting the power supply lines. An external direction diode can be added. (3) Power supply Lines Design PCB layout pattern to provide low impedance GND and supply lines. To obtain a low noise ground and supply ...
Asynchronous machine
Asynchronous machine

... • No-load test at nominal voltage and frequency • Blocked rotor test at nominal current, reduced voltage and frequency • DC-resistance measurement ...
IXDD404 - IXYS Power
IXDD404 - IXYS Power

... larger than the load capacitance. Usually, this would be achieved by placing two different types of bypassing capacitors, with complementary impedance curves, very close to the driver itself. (These capacitors should be carefully selected, low inductance, low resistance, high-pulse current-service c ...
MT-FD 6 - Newmar
MT-FD 6 - Newmar

... 1) DIP Switches Programming is provided though three sets of DIP switch modules. One per each Load Group. Each set is divided into two sections. The first section, made up of switches 5 & 6, is for selecting the power activation MODE to the Load Group. The second section, made up of switches 1 throu ...
TDK5111F 315 MHz ASK/FSK Transmitter in 10-pin Package
TDK5111F 315 MHz ASK/FSK Transmitter in 10-pin Package

... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effective ...
CrktCT -1
CrktCT -1

... Answer: Use P = V2/Rtot For bulbs B and C, Rtot = 2R. Total power in B+C < power in A. CrktCT -10. Two light bulbs A and B are connected in series to a constant voltage source. When a wire is connected across B as shown, the brightness of bulb A ... A: increases B: decreases, but remains glowing C: ...
Three-Phase High-Power and Zero-Current-Switching OBC
Three-Phase High-Power and Zero-Current-Switching OBC

... of the conversion efficiency, soft switching technology is widely used in the DC/DC converter. The most commonly-used topologies are the phase shifted zero-voltage-switching (ZVS) topology [6–10] and the resonant tank with two inductors and a capacitor (LLC) resonant topology [11–13]. The shifted ZV ...
MAX4684/MAX4685 0.5Ω/0.8Ω Low-Voltage, Dual SPDT Analog
MAX4684/MAX4685 0.5Ω/0.8Ω Low-Voltage, Dual SPDT Analog

... current limited. If this sequencing is not possible, and if the analog inputs are not current limited to <20mA, add a small signal diode (D1) as shown in Figure 1. Adding a protection diode reduces the analog range to a diode drop (about 0.7V) below V+ (for D1). RON increases slightly at low supply ...
AMP02 英文数据手册DataSheet 下载
AMP02 英文数据手册DataSheet 下载

... to exceed the dynamic range of the input amplifiers. The amplified differential input signal and the input common-mode voltage must not force the amplifier’s output voltage beyond ± 12 V (VS = ± 15 V) or nonlinear operation will result. ...
< 1 ... 597 598 599 600 601 602 603 604 605 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report