Impedance Matching
... Reflected power results when the load impedance is not matched to the generator’s requirements. Load power is the amount of power that is actually delivered to the load; in most cases, this is accepted as being equal to the forward power minus the reflected power. Some generators accurately measure ...
... Reflected power results when the load impedance is not matched to the generator’s requirements. Load power is the amount of power that is actually delivered to the load; in most cases, this is accepted as being equal to the forward power minus the reflected power. Some generators accurately measure ...
KA79MXX / LM79MXX 3-Terminal 0.5 A Negative Voltage Regulator KA79MXX /
... 4. To specify an output voltage, substitute voltage value for "XX". 5. CI is required if the regulator is located an appreciable distance from the power supply filter. For value given, capacitor must be solid tantalum. If aluminium electronics are used, 25 μF aluminum electrolytic may be substituted ...
... 4. To specify an output voltage, substitute voltage value for "XX". 5. CI is required if the regulator is located an appreciable distance from the power supply filter. For value given, capacitor must be solid tantalum. If aluminium electronics are used, 25 μF aluminum electrolytic may be substituted ...
ZNBG4003
... 8. Noise voltage measurements are made with FETs and gate and drain capacitors of value 10nF in place. Noise voltages are not measured in production. ...
... 8. Noise voltage measurements are made with FETs and gate and drain capacitors of value 10nF in place. Noise voltages are not measured in production. ...
FFPF60SA60DS STEALTH 8 A, 600 V, STEALTH Dual Series Diode
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
Compact Contactless Power Transfer System for Electric Vehicles
... performed. 2. The capacitances of the resonant capacitors are independent of the output power. 3. If the primary voltage/current is constant, the secondary voltage/current will also be constant regardless of the load change. 4. The theoretical equation for the efficiency can be easily derived. This ...
... performed. 2. The capacitances of the resonant capacitors are independent of the output power. 3. If the primary voltage/current is constant, the secondary voltage/current will also be constant regardless of the load change. 4. The theoretical equation for the efficiency can be easily derived. This ...
SMA SPEEDWIRE/WEBCONNECT Piggy-Back
... (see Section 2.2). For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product. The enclosed documentation is an integral part of this product. • Read and observe the documentation. ...
... (see Section 2.2). For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product. The enclosed documentation is an integral part of this product. • Read and observe the documentation. ...
MAX13041 ±80V Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN
... and allows communication at speeds up to 1Mbps. The extended fault-protected voltage range of ±80V on CAN bus lines allows for use in +12V or +42V automotive, and higher voltage +24V and +36V mid-heavy truck applications. Advanced power management features make the MAX13041 ideal for automotive elec ...
... and allows communication at speeds up to 1Mbps. The extended fault-protected voltage range of ±80V on CAN bus lines allows for use in +12V or +42V automotive, and higher voltage +24V and +36V mid-heavy truck applications. Advanced power management features make the MAX13041 ideal for automotive elec ...
part 2 products - GE Grid Solutions
... starting/stopping the inverter section of the UPS modules in response to changes in load demand. The user shall be able to select the required redundancy level in IEMi mode (either N+1 or N+2). Given this constraint, the UPS system shall operate with a subset of UPSs modules in order to improve syst ...
... starting/stopping the inverter section of the UPS modules in response to changes in load demand. The user shall be able to select the required redundancy level in IEMi mode (either N+1 or N+2). Given this constraint, the UPS system shall operate with a subset of UPSs modules in order to improve syst ...
S280-42-1
... • Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. • Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. • Is trained in the care and use of protective equipment such as flash clothing, safety glasses ...
... • Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. • Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. • Is trained in the care and use of protective equipment such as flash clothing, safety glasses ...
DAC5662A 数据资料 dataSheet 下载
... The DAC5662A has two 12-bit parallel input ports with separate clocks and data latches. For flexibility, the DAC5662A also supports multiplexed data for each DAC on one port when operating in the interleaved mode. The DAC5662A has been specifically designed for a differential transformer coupled out ...
... The DAC5662A has two 12-bit parallel input ports with separate clocks and data latches. For flexibility, the DAC5662A also supports multiplexed data for each DAC on one port when operating in the interleaved mode. The DAC5662A has been specifically designed for a differential transformer coupled out ...
review of ground fault protection methods for
... high-resistance ground faults on these systems is difficult because the protective relay measures the high-resistance ground fault current combined with the unbalance current. Ground faults on these systems may produce high-magnitude currents that require tripping the entire circuit and interrupting ...
... high-resistance ground faults on these systems is difficult because the protective relay measures the high-resistance ground fault current combined with the unbalance current. Ground faults on these systems may produce high-magnitude currents that require tripping the entire circuit and interrupting ...
Project Plan - W.omsar.gov.lb
... Environmental Control: Examines the setting of the Data Center and the means necessary to optimize it. See Section 5.0. Power Source: Identifies the different power configurations and power management tools and helps lay the ground for power planning and design. See Section 6.0. Fire Retardation: He ...
... Environmental Control: Examines the setting of the Data Center and the means necessary to optimize it. See Section 5.0. Power Source: Identifies the different power configurations and power management tools and helps lay the ground for power planning and design. See Section 6.0. Fire Retardation: He ...
Strain Gages and Signal Conditioning
... length. This is why in case of stress concentration small basis is used (0,5-3 mm). In case of linear distribution of stresses larger gauge lengths are used (5-30 mm). Relatively large basis (over 30 mm) is used in case of determining mechanical properties of a body which takes place usually when st ...
... length. This is why in case of stress concentration small basis is used (0,5-3 mm). In case of linear distribution of stresses larger gauge lengths are used (5-30 mm). Relatively large basis (over 30 mm) is used in case of determining mechanical properties of a body which takes place usually when st ...
6A, Current-Sharing Dual LDO
... Notice that, unlike the ideal configuration, both LDOs each have a resistor network to set their output voltage. The reason for this is because the master LDO needs its own network as it will essentially be the point of reference for the slave LDO. As the op amp measures the differential between the ...
... Notice that, unlike the ideal configuration, both LDOs each have a resistor network to set their output voltage. The reason for this is because the master LDO needs its own network as it will essentially be the point of reference for the slave LDO. As the op amp measures the differential between the ...
SP3203E 数据资料DataSheet下载
... generally accepted ESD testing method for semiconductors. This method is also specified in MIL-STD-883, Method 3015.7 for ESD testing. The premise of this ESD test is to simulate the human body’s potential to store electro-static energy and discharge it to an integrated circuit. The simulation is pe ...
... generally accepted ESD testing method for semiconductors. This method is also specified in MIL-STD-883, Method 3015.7 for ESD testing. The premise of this ESD test is to simulate the human body’s potential to store electro-static energy and discharge it to an integrated circuit. The simulation is pe ...
SI unit for EtherNet/IP EX250-SEN1
... ♦Follow the instructions given below when handling reduced-wiring system: Or it will have a risk of being damaged and operating failure. ♦The instructions on selection (installation, wiring, environment of use, adjustment, operation and maintenance) described below must also be followed. ∗Product sp ...
... ♦Follow the instructions given below when handling reduced-wiring system: Or it will have a risk of being damaged and operating failure. ♦The instructions on selection (installation, wiring, environment of use, adjustment, operation and maintenance) described below must also be followed. ∗Product sp ...
modeling and control of the ultracapacitor
... Because of the limited current capability of the dc–dc converter, the bandwidth of the ultracapacitor voltage controller is much lower than that of the dc-bus voltage controller. Therefore, the integral gain kIC0 is low, and (23) can be further simplified as ...
... Because of the limited current capability of the dc–dc converter, the bandwidth of the ultracapacitor voltage controller is much lower than that of the dc-bus voltage controller. Therefore, the integral gain kIC0 is low, and (23) can be further simplified as ...
VOD223T - Vishay
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
NPCC Glossary of Terms - Northeast Power Coordinating Council
... cascading outages will not occur due to operation of protective devices upon the failure of facilities. (Various definitions of equipment ratings are found elsewhere in this glossary.) An Area (when capitalized) refers to one of the following: New England, New York, Ontario, Quebec or the Maritimes ...
... cascading outages will not occur due to operation of protective devices upon the failure of facilities. (Various definitions of equipment ratings are found elsewhere in this glossary.) An Area (when capitalized) refers to one of the following: New England, New York, Ontario, Quebec or the Maritimes ...
26 24 16 Panelboards - UNL CMS
... not incorporate any other components which may degrade performance or reliability of the suppression system. The fusing system shall be capable of allowing the rated maximum surge current to pass through without fuse operation. Systems utilizing a fusing system that opens below the maximum surge cur ...
... not incorporate any other components which may degrade performance or reliability of the suppression system. The fusing system shall be capable of allowing the rated maximum surge current to pass through without fuse operation. Systems utilizing a fusing system that opens below the maximum surge cur ...
Operation manual for BLHeli Atmel Rev13.x
... input signal in environments where the ESC takes its input from a source that would normally drive a brushed motor. The code also supports regular 1-2ms pulse width PPM input or OneShot125 (125-250us), at a rate up to around 500Hz. The input signal is automatically detected by the ESC upon power up ...
... input signal in environments where the ESC takes its input from a source that would normally drive a brushed motor. The code also supports regular 1-2ms pulse width PPM input or OneShot125 (125-250us), at a rate up to around 500Hz. The input signal is automatically detected by the ESC upon power up ...