• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CHEC Generation Guide
CHEC Generation Guide

... concerned. These types include: (a) solid-state or static inverters, (b) induction machines, and (c) synchronous machines. Many smaller renewable energy systems produce grid quality AC power through an inverter and are therefore typically grouped together. Induction and synchronous generators, on th ...
PSPICE University of Pennsylvania Department of Electrical and Systems Engineering
PSPICE University of Pennsylvania Department of Electrical and Systems Engineering

... The AC analysis will apply a sinusoidal voltage whose frequency is swept over a specified range. The simulation calculates the corresponding voltage and current amplitude and phases for each frequency. When the input amplitude is set to 1V, then the output voltage is basically the transfer function. ...
SP3491 数据资料DataSheet下载
SP3491 数据资料DataSheet下载

... The SP3490 and the SP3491 are +3.3V low power full duplex transceivers that meet the specifications of the RS-485 and RS-422 serial protocols. These devices are pin-to-pin compatible with the Sipex SP490 and SP491 devices as well as popular industry standards. The SP3490 and the SP3491 feature Sipex ...
Directivity and VSWR Measurements
Directivity and VSWR Measurements

... is how well the impedance of the load matches to the impedance of the source. This match determines how much power can be delivered and how much will be reflected back to the transmitter as measured by the return loss, or ratio of reflected power to transmitted power. Traditionally this quality of a ...
MAX6709/MAX6714 Low-Voltage, High-Accuracy, Quad Voltage Monitors in µMAX Package General Description
MAX6709/MAX6714 Low-Voltage, High-Accuracy, Quad Voltage Monitors in µMAX Package General Description

... asserts low when VCC drops below its threshold or MR is driven low. Each of the three power-fail inputs connects directly to one of the comparator inputs. When any input is higher than the threshold level, the output is high. The output goes low as the input drops below the threshold voltage. The un ...
1. Introduction - About the journal
1. Introduction - About the journal

... the CFA-based oscillators over their VFA (Voltage Feedback Amplifier) counterparts [11], these oscillators also provide only voltage outputs. CFA-based oscillators with explicit current outputs are proposed in [13] (Fig. 4). However, the load resistance affects the oscillator behavior. The purpose o ...
Immersion Heater controller
Immersion Heater controller

... Component X2 is a Diac (32V), although shown as a Triac on the diagram (look very similar schematically) ...
Volume 45, Number 1, 2011
Volume 45, Number 1, 2011

LTC3672B-2
LTC3672B-2

... set during manufacturing to 1.2V nominal for the buck, 2.8V nominal for LDO1, and 1.8V nominal for LDO2. For versions of the IC with different output regulation voltages, consult the LTC factory. SYNCHRONOUS BUCK REGULATOR The synchronous buck uses a constant-frequency current mode architecture, swi ...
Aalborg Universitet Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed
Aalborg Universitet Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed

DATA  SHEET CGY2014TT GSM/DCS/PCS power amplifier Product specification
DATA SHEET CGY2014TT GSM/DCS/PCS power amplifier Product specification

... Fix the component by first soldering two diagonally-opposite end leads. Use a low voltage (24 V or less) soldering iron applied to the flat part of the lead. Contact time must be limited to 10 seconds at up to 300 °C. ...
MAX9218 27-Bit, 3MHz-to-35MHz DC-Balanced LVDS Deserializer General Description
MAX9218 27-Bit, 3MHz-to-35MHz DC-Balanced LVDS Deserializer General Description

... DC balance. The DC balance allows AC-coupling, providing isolation between the transmitting and receiving ends of the interface. The MAX9218 features a selectable rising or falling output latch edge. ESD tolerance is specified for ISO 10605 with ±10kV contact discharge and ±30kV air discharge. The M ...
MAX5073 2.2MHz, Dual-Output Buck or Boost Converter with Internal Power MOSFETs General Description
MAX5073 2.2MHz, Dual-Output Buck or Boost Converter with Internal Power MOSFETs General Description

... 5.5V to 23V input voltage range. Each output is programmable down to 0.8V in the buck mode and up to 28V in the boost mode with an output voltage accuracy of ±1%. In the buck mode, converter 1 and converter 2 can deliver 2A and 1A, respectively. The output switching frequency of each converter can b ...
DMMS 350+ - Electro Industries
DMMS 350+ - Electro Industries

... other fixed ratio designs shall not be acceptable. 5. Voltage and current connections shall be segregated from each other on the back of the monitor to provide safe connections. C. The Monitor shall have an accuracy of +/- 0.2% or better for volts and amps, and 0.4% for power functions. 1. The Monit ...
FDMF6705 - Extra-Small, High-Performance, High- Frequency DrMOS Module FDMF6705 - Extra-Small High-Perfo Description
FDMF6705 - Extra-Small, High-Performance, High- Frequency DrMOS Module FDMF6705 - Extra-Small High-Perfo Description

... window. When the PWM input signal enters and remains within the 3-state window for a defined hold-off time (tD_HOLD-OFF), both GL and GH are pulled LOW. This feature enables the gate drive to shut down both highand low-side MOSFETs to support features such as phase shedding, which is a common featur ...
Immersion Heater Controller
Immersion Heater Controller

... Component X2 is a Diac (32V), although shown as a Triac on the diagram (look very similar schematically) ...
LT5514
LT5514

... Note 1: Absolute Maximum Ratings are those values beyond which the life of the device may be impaired. Note 2: All voltage values are with respect to ground. Note 3: Default state for open PGA inputs. Note 4: VCC1 and VCC2 (Pins 2 and 19) are internally connected. Note 5: External VOSUP is adjusted ...
Line Differential Protection Under Unusual System Conditions
Line Differential Protection Under Unusual System Conditions

... events, even if these functions are not purposefully inhibited for security reasons. Consider the concept of memory polarization in an impedance element: it works assuming the prefault and fault voltages do not differ considerably in phase. Therefore, it may fail to operate dependably under unstable ...
mae511
mae511

Lab – 1: Linear Solenoid Actuator
Lab – 1: Linear Solenoid Actuator

... The goal of this task is to measure the force profile of the solenoid at a given current. This is done by performing several measurements of the holding force at different plunger positions. Each force measurement is performed by pulling on the Lever Arm (see Figure 4) until the plunger breaks free ...
BCP 54/ 55/ 56 Features Mechanical Data
BCP 54/ 55/ 56 Features Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
1 Static Characteristics I
1 Static Characteristics I

AN-960 APPLICATION NOTE
AN-960 APPLICATION NOTE

... for RS-422. The common-mode voltage range for RS-485 is expanded to −7 V to +12 V. The RS-485 transceivers must withstand this common-mode voltage range while tristated (disconnected from the bus). ...
Deney2
Deney2

... The current(iD) in the diode is determined by the voltage(vD) applied across the diode terminals, and the diode is shown with voltage applied in Fig.1a. The relationship between the current in the diode and the voltage applied to diode is called the i-v characteristics of diode and graph of i-v char ...
Lab: Building Series and Parallel Circuits
Lab: Building Series and Parallel Circuits

... What happens when the second bulb is unfastened (again with the first one reconnected)? ...
< 1 ... 167 168 169 170 171 172 173 174 175 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.