• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SFH620AA, SFH620AGB
SFH620AA, SFH620AGB

... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
PROLOG SYNTAX AND MEANING
PROLOG SYNTAX AND MEANING

Transmission-Line Fault Analysis Using
Transmission-Line Fault Analysis Using

... rules even in case of complex networks, cannot classify all types of faults. In [7], a setting-free two-end method compares the direction of the power measured at two ends and detects and classifies the fault using established rules. Though the method is a setting-free one, calculating the average v ...
Definition and Classification of Power System Stability IEEE/CIGRE
Definition and Classification of Power System Stability IEEE/CIGRE

... reach a new equilibrium state with the system integrity preserved i.e., with practically all generators and loads connected through a single contiguous transmission system. Some generators and loads may be disconnected by the isolation of faulted elements or intentional tripping to preserve the cont ...
What is a Switch?
What is a Switch?

... – DC –Direct Current (minimum UL requirements) – Horsepower (for switches designed to control small motor loads) ...
LTC3405A-1.5/LTC3405A-1.8 - 1.5V, 1.8V, 1.5MHz, 300mA
LTC3405A-1.5/LTC3405A-1.8 - 1.5V, 1.8V, 1.5MHz, 300mA

... MAXIMUM OUTPUT CURRENT (mA) ...
fulltext
fulltext

... joining metals. It has extensive applications in household appliances and in automotive industries. The traditional approach in relation to spot welding machines is to use 50 Hz welding transformers. The drawback associated with these transformers is that they are both heavy and bulky. Moreover, the ...
No.17 Single-transistor Reflex Radio
No.17 Single-transistor Reflex Radio

... The superheterodyne receiver is a radio design that was invented by Edwin Armstrong, an American engineer. High-frequency signals cannot be amplified more than once. In order to amplify such signals, Armstrong came up with an idea to use an intermediate-frequency signal amplifier. After high-frequen ...
1 - Monash University Research Repository
1 - Monash University Research Repository

... different positions along feeder section, before and after compensation (K=-0.2, a>c= 5rad/s) ...
Types Of Load Centers
Types Of Load Centers

... Service-entrance conductors must have a readily accessible means of being disconnected from the power supply. NEC® Article 230.71(A) specifies that for each set of service entrance conductors no more than six switches or circuit breakers shall be used to disconnect and isolate the service from all o ...
Signal Integrity Analysis of Package and PCB for High Speed Data
Signal Integrity Analysis of Package and PCB for High Speed Data

DRM039, Single Phase AC Induction Motor Control Reference Design
DRM039, Single Phase AC Induction Motor Control Reference Design

... This application note describes a new control technique of the single-phase a.c. induction motor. It presents a design of a low-cost, high-efficiency drive capable of supplying a single-phase a.c. induction motor with a PWM modulated sinusoidal voltage. The circuit operation is controlled by a tiny ...
RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE
RF7163 QUAD-BAND GSM850/EGSM900/DCS1800/ PCS1900 TRANSMIT MODULE

... builds upon RFMD’s leading power amplifier with PowerStar® integrated power control technology, pHEMT switch technology, and integrated transmit filtering for best-in-class harmonic performance. The results are high performance, reduced solution size, and ease of implementation. The device is design ...
A Comparison of CML and LVDS for High
A Comparison of CML and LVDS for High

The New PL and New PL-P Series of manual and bus
The New PL and New PL-P Series of manual and bus

Copper Development Association
Copper Development Association

... Nuisance tripping can occur in the presence of harmonics for two reasons:  Residual current circuit breakers are electromechanical devices. They may not sum higher frequency components correctly and therefore trip erroneously.  The current flowing in the circuit will be higher than expected due to ...
BDTIC www.BDTIC.com/infineon AN2011-04  MA3L080E07_EVAL Evaluation Adapter Board for EconoPACK
BDTIC www.BDTIC.com/infineon AN2011-04 MA3L080E07_EVAL Evaluation Adapter Board for EconoPACK

... Evaluation Driver Board for 3-Level EconoPACKTM 4 AN2011-03 Due to IGBT short circuit performance a maximum value of VGE ~15V is recommended. ...
Institutionen för systemteknik Department of Electrical Engineering A “Divide-by-Odd Number” Injection-Locked Frequency Divider.
Institutionen för systemteknik Department of Electrical Engineering A “Divide-by-Odd Number” Injection-Locked Frequency Divider.

... First of all I would like to thank Almighty Allah,who gave me strength and knowledge to carry out my masters degree and thesis work. I would like to thank my parents and family who were always there to provide me with moral support and gave me the confidence to accomplish my study tasks. Secondly, I ...
DIGITAL AC POWER MONITOR DSP-  OSI
DIGITAL AC POWER MONITOR DSP- OSI

... All of the remaining commands, unless otherwise noted, are disabled by a hardware lockout. Program parameters are stored in EEPROM non-volatile memory. To enable programming, connect a short length of wire (jumper) between terminal numbers 2 and 3. After setting needed parameters with the following ...
Guide for the Design and Production of LV Power Factor Correction
Guide for the Design and Production of LV Power Factor Correction

ZXTN25100BFH
ZXTN25100BFH

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Railguns
Railguns

... flow and r is a vector from dl to the point at which the field is being evaluated. ...
Synchronization of underdamped Josephson-junction arrays
Synchronization of underdamped Josephson-junction arrays

... number of junctions and will become stable when more junctions are biased. This can be seen in Fig. 3(a). If the bias current is fixed at I/IC = 0.59, corresponding to the horizontal dotted line, a small number of junctions can not be biased on the resonant step, because the steps do not extend up t ...
Section 1 TVS Diode Definition and General Electronics Applications
Section 1 TVS Diode Definition and General Electronics Applications

Relays General information
Relays General information

... electrical contact to effect the operation of other devices in the same or another circuit. Relays are an important factor in today's industrial processes. More than 25 billion relays operate today all over the world as an interface between electrical control circuits and electrical loads. Technical ...
< 1 ... 119 120 121 122 123 124 125 126 127 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report