• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The development of a miniaturized hydration sensor
The development of a miniaturized hydration sensor

... detection  of  changes  in  the  concentration  of  different  molecules  in  the  human  body  which are indicators of changes in the human body electrochemical balance, helping to  monitor different pathologies. Making use of the membrane’s physical (porous size and  density),  chemical  and  elec ...
LABORATORY MANUAL Electronics II  EEL 4309
LABORATORY MANUAL Electronics II EEL 4309

... Avoid contact with conductors in energized electrical circuits. The typical cannot let-go (the current in which a person cannot let go) current is about 6-30 ma (OSHA). Muscle contractions can prevent the person from moving away the energized circuit. Possible death can occur as low 50 ma. For a per ...
Introduction to Circuit Protection, Control, and Measurement
Introduction to Circuit Protection, Control, and Measurement

UT64CAN333x CAN FD Transceivers
UT64CAN333x CAN FD Transceivers

... devices is the same; however, the common mode output voltage will vary between the 5 V and 3.3 V devices. Since the common mode output voltage may vary slightly, Cobham recommends that system level testing be performed to understand and maximize the performance of operations when using mixed supply ...
Sealed Lead-Acid Batteries Technical Handbook 2000
Sealed Lead-Acid Batteries Technical Handbook 2000

... recommended cut-off voltage may generate heat, resulting in the deformation of the battery or in condensation around the battery cover caused when moisture within the battery evaporates. In addition, the efficiency of the battery would eventually decrease. Overdischarging a battery may result in red ...
INSTRUCTION MANUAL DISTANCE RELAY GRZ100
INSTRUCTION MANUAL DISTANCE RELAY GRZ100

... There are various causes for measuring errors in a distance relay. In the case of a fault with resistance, the reactance component seen by the relay at the power sending terminal is smaller than the actual value and it tends to overreach. On the contrary, the reactance component seen by the relay at ...
INSTRUCTION MANUAL DISTANCE RELAY GRZ100
INSTRUCTION MANUAL DISTANCE RELAY GRZ100

... There are various causes for measuring errors in a distance relay. In the case of a fault with resistance, the reactance component seen by the relay at the power sending terminal is smaller than the actual value and it tends to overreach. On the contrary, the reactance component seen by the relay at ...
Trans-Impedance Amplifier (TIA)
Trans-Impedance Amplifier (TIA)

Instructions for Installation, Operation and Maintenance of the Cutler
Instructions for Installation, Operation and Maintenance of the Cutler

... Inverse Time Overcurrent Phase, I4T Curves (SC-5390-92B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inverse Time Overcurrent Phase, I2T Curves (SC-5391-92B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inverse Time Overcurrent Phase, IT Curves (SC-5392-92B) . ...
Fault Location Algorithms for Electrical Power Transmission Lines
Fault Location Algorithms for Electrical Power Transmission Lines

... delivering electricity to consumers at their homes, offices and industries. It is important to ensure a smooth operation of transmission lines to deliver a minimally interrupted power supply making necessary for reliable operation of electrical power lines. This need has given rise to Fault Location ...
- Premier University of Technology
- Premier University of Technology

Probing 6 hints webcast
Probing 6 hints webcast

... Now that you figure out how to lower the oscilloscope’s vertical noise with one of the techniques above, let’s take a look at how to improve accuracy and sensitivity of a clamp-on current probe. There are two useful tips for using this type of current probe: To ensure accurate measurement of low-lev ...
Western Power`s Technical Rules
Western Power`s Technical Rules

... the requirements for the operation of the transmission and distribution systems (including the operation of the transmission and distribution systems in emergency situations or where there is a possibility of a person suffering injury but excluding the operation of those parts of the transmission sy ...
ICD PDN Planner Help Guide
ICD PDN Planner Help Guide

VAMP 321 Arc-fault Detection System for
VAMP 321 Arc-fault Detection System for

... Connecting the VAMP 321 I/O units ................................................... 72 Connecting the secondary circuits of the current transformers (VAM 4C / VAM 4CD only) ........................................................ 72 Connecting the trip circuits of the circuit breakers ............ ...
Liebert NXC  from 10 to 20kVA
Liebert NXC from 10 to 20kVA

...  Compatible with two modes: 3-phase and single-phase outputs. The system wiring must be checked and the panel setting must be conducted manually  Up to 4 units maybe connected in parallel, in order to form a n+1 redundant parallel system  High-frequency, double conversion topology, with high inpu ...
25 Watt - EPtronics
25 Watt - EPtronics

... of LED power supplies. We develop and continuously grow our line of LED drivers based on field applications and input from customers including many leaders in the LED lighting industries. As one of the few power conversion companies in the world with an exclusively dedicated focus in LED illuminatio ...
characterization, modeling, and design of esd
characterization, modeling, and design of esd

Ultra Linear Low-Loss Varactor Diode Configurations for Adaptive RF Systems
Ultra Linear Low-Loss Varactor Diode Configurations for Adaptive RF Systems

... best to use small diodes in the center-tap connection. Above the corner frequency (in this case approximately 40 MHz), defined by (11), fifth-order distortion constrains the linearity. Note that the corner frequency is ten times larger than the single resistor (100 k ) is ten times smaller, which ca ...
PQMII Power Quality Meter Instruction Manual
PQMII Power Quality Meter Instruction Manual

Instruction Book M-3410A Intertie/Generator Protection Relay
Instruction Book M-3410A Intertie/Generator Protection Relay

... Target/Status Indicators and Controls The RELAY OK LED reveals proper cycling of the microprocessor. The DIAGNOSTIC LED provides indication of the error code (when flashing). The OSC TRIGGER LED indicates that the oscillograph has been triggered. The remaining eleven LEDs are used to indicate which ...
LTM4601A/LTM4601A-1 – 12A µModule Regulators with PLL
LTM4601A/LTM4601A-1 – 12A µModule Regulators with PLL

... cycling endurance. Operating over an input voltage range of 4.5V to 20V, the LTM4601A supports an output voltage range of 0.6V to 5V as well as output voltage tracking and margining. The high efficiency design delivers 12A continuous current (14A peak). Only bulk input and output capacitors are need ...
INVESTIGATION OF HIGH-PERFORMANCE DC-DC CONVERTERS FOR PLUG-
INVESTIGATION OF HIGH-PERFORMANCE DC-DC CONVERTERS FOR PLUG-

... and they have been appropriately cited. Some sections of the chapter are also modified from previously written introductory material from my master’s thesis entitled “Soft-Switched DC-to-DC Converters for Power Conditioning of Electrolyzer in a Renewable Energy System” (2006) completed at the Univer ...
3-phase BLDC Motor Control with Sensorless Back-EMF
3-phase BLDC Motor Control with Sensorless Back-EMF

... The branch voltage uVC can be calculated when considering the above conditions: ...
Low Power Consumption (cont.)
Low Power Consumption (cont.)

...  To unfailingly reset the LSI, the RES# pin should be held low for the specified power supply stabilization time at a power-on  When the RES# pin is driven high from low, the internal reset is canceled after the post-RES# cancellation wait time ...
< 1 ... 8 9 10 11 12 13 14 15 16 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.