• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DSL  Primary Switched Battery Charging and Power Supply Unit GL4024
DSL Primary Switched Battery Charging and Power Supply Unit GL4024

cired wide area control strategy for multiple vsc
cired wide area control strategy for multiple vsc

...  It improves system stability significantly due to the decoupling of the AC systems, in other words, fault in one AC system will not affect the rest of the system. However, DC transmission systems are sensitive to small changes in voltage and vulnerable to DC faults. A fault in one of the DC links ...
Stakeholder Comment and Rationale Form  AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft
Stakeholder Comment and Rationale Form AESO AUTHORITATIVE DOCUMENT PROCESS Stakeholder Consultation Draft

... The AESO is seeking comments from stakeholders with regard to the following matters: 1. Are there any subsections where stakeholders feel that language does not clearly articulate the requirement for either the AESO or a market participant? If yes, please indicate the subsections and suggest langua ...
How to diagnose a reverse polarity, bad ground, etc
How to diagnose a reverse polarity, bad ground, etc

... ground circuit. Ground circuits are important in that if there is a problem with the power circuit this ground will safely carry away the power and send it into the ground. Also this ground is important to controls that use igniters that operate on less than full voltage. These controls need a place ...
Dura-Bilt5i MV V
Dura-Bilt5i MV V

... • Ratings based on a variable torque load (industrial fans and pumps). • For constant torque load applications, a de-rate factor should be applied. Consult the TMEIC Application Center. • Altitude above sea level is 0-3300 ft (0-1000 m). 2. An optional bypass cabinet can be integrated into the line ...
Problem Set
Problem Set

TPS61251
TPS61251

monitoring of energy quality for residential consumers
monitoring of energy quality for residential consumers

800 kVA - 1153 Amps per phase
800 kVA - 1153 Amps per phase

... All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitc ...
ExIIrev05ans
ExIIrev05ans

... B: The electric field might be zero, or it might be non-zero and perpendicular to the line ab. D: The electric field can vary along the line ab, but it must have the same value at points a and b. E: You can conclude absolutely nothing about the electric field. Answer: The electric field might be zer ...
II. H∞ output feedback controller design
II. H∞ output feedback controller design

preview - SOL*R
preview - SOL*R

... ROOT MEAN SQUARE OF AC COMPONENT — V ACrms A third type of average is also important. This is the root-mean-square of VAC. This quantity describes the size of oscillations of the waveform without the DC component. VAC is defined as whatever is left after the DC component is removed. ...
Model 480 Universal Voltage Regulator
Model 480 Universal Voltage Regulator

... with all single and three phase systems from 100V to 480V, 50 or 60 Hz by connecting four or five wires. It works with brushless exciters or conventional fields. Field excitation of up to 5 A is provided by means of a phase-controlled SCR. The unit is internally fused and includes a heavy-duty EMI f ...
Assembly Notes
Assembly Notes

... panels can be installed. You may need to push the button tops down firmly so that they can move freely through the panel holes. Slightly trim the three button tops adjacent to the LCD module if you see that they interfere. 1. You will probably need to make a simple probe. This can easily be made wit ...
LVR125S
LVR125S

... fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. 5. In most applications, power must be removed and the fault condition cleared in order to reset a PPTC device; however, under certain unusual conditions, a PPTC device may automatically ...
Applications of Semiconductor devices – Switches.
Applications of Semiconductor devices – Switches.

... An opto-isolator can also be constructed using a small incandescent lamp in place of the LED; such a device, because the lamp has a much slower response time than an LED, will filter out noise or half-wave power in the input signal. In so doing, it will also filter out any audio- or higher-frequenc ...
Arc Fault Circuit Interrupter Explained
Arc Fault Circuit Interrupter Explained

... breaker. Overload fault circuit interrupters (OFCI) are designed to protect against excess current drawn by utilization equipment. OFCIs must be located within receptacles. Both thermal circuit breakers and OFCIs are required to prevent fire ignition from excess current. High line-voltage creates e ...
Potential Dividers
Potential Dividers

... If we move S to the right, VAS rises and forces current back through the galvo and cell, the other way. We now know that V = VAS. ...
HT2413701376
HT2413701376

Automotive Electronics Product Information Lambda Probe Interface
Automotive Electronics Product Information Lambda Probe Interface

Enhanced Output Short Circuit Protection
Enhanced Output Short Circuit Protection

... reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or c ...
Alternating Current - Happy Physics With Mineesh Gulati
Alternating Current - Happy Physics With Mineesh Gulati

... The voltage across a resistor R is in phase with the current. The voltage across an inductor L leads the current by 90°(Φ=+90°), while the voltage across capacitor C lags the current by 90°(Φ=-90°) . The voltage amplitude across each type of device is proportional to the current amplitude I. An ind ...
Syllabus EE 435
Syllabus EE 435

Why are Low Impedance Microphones Better Than High
Why are Low Impedance Microphones Better Than High

... To do this we first need a circuit model (and then math model) of how a microphone works together with the amplifier it plugs into. So, first there is the microphone... whose job it is to generate a wiggling voltage... so it is a time-varying voltage source... and because it is not an ideal source i ...
36 - BSNL Durg SSA(Connecting India)
36 - BSNL Durg SSA(Connecting India)

... The value chosen by most administrations is usually not more than ten ohms, although in some isolated cases higher values are acceptable. ...
< 1 ... 1047 1048 1049 1050 1051 1052 1053 1054 1055 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.