• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Philosophy of Topology and Components Selection for
Philosophy of Topology and Components Selection for

... reduction of the product for the customer. In the automotive industry this requirement is much stronger because of the price of troubleshooting is much higher than in the industrial and commercial markets. That’s why more reliable design is preferable. For example: resonant topologies with clamp dio ...
Product Data: CCLD Laser Tacho Probe — MM
Product Data: CCLD Laser Tacho Probe — MM

... For each pass of the target, a negative 0.8 Vp pulse is output, DC biased between +18.0 V and +19.5 V. MM-0360 is capable of measuring down to 0 RPM* when used with measurement system capable of DC coupling of the CCLD power supply such as in the Brüel & Kjær LAN-XI family of data acquisition hardwa ...
CN-0115
CN-0115

... The OP184 is a single op amp that offers a high slew rate, low noise, and rail-to-rail input and output. In the circuit, it is configured in the follower mode. It guarantees that the output voltage, VOUT, is equal to the voltage set in the digital potentiometer by driving the BSS138 NMOS transistor. ...
COOPER LIGHTING - SURE
COOPER LIGHTING - SURE

MS Word
MS Word

... (b) Now suppose we switch transistors where the new transistor has a 50% higher value for kn. By what percentage does drain current ID change as a result? ...
exp06
exp06

... introducing positive feedback. Positive feedback can increase the switching speed of the comparator and provide noise immunity at the same time. • The voltage range over which the signal does not switch is called the hysteresis (In this case, h=2d) Can you explain how this works? ...
Series and Parallel Circuits Computer Lab
Series and Parallel Circuits Computer Lab

... E. Place the non-contact ammeter crosshairs over the moving blue dots. What is the current? __________ F. Right click on the battery to change the voltage. What happens to the readings on the voltmeter and ammeter when you triple the voltage of the battery? What happens to brightness of the light bu ...
Multilevel Inverters with Imbricated Switching Cells, PWM
Multilevel Inverters with Imbricated Switching Cells, PWM

... where fCk and fCk+1 stand for the connection functions for Ak and Ak+1 switches and can only have two values: 0 or 1 (according to the state of the switches) [5]. For instance, if fCk =1 when the Ak switch is off and fCk=0 when the Ak switch is on. For multilevel converters, in order to obtain equal ...
Labf2003_4 - University of Kentucky College of Engineering
Labf2003_4 - University of Kentucky College of Engineering

ground fault neutralizer
ground fault neutralizer

Soundmate Easy
Soundmate Easy

DN505 - Dual Controller Provides 2μs Step
DN505 - Dual Controller Provides 2μs Step

... Figure 1 shows a dual 25A output buck converter synchronized to an external 300kHz clock. The controlled constant on-time valley current mode architecture allows the switch node pulses to temporarily compress when a 5A to 25A load step is applied to the 1.2V rail, resulting in a voltage undershoot o ...
Mobile Radiographic Equipment
Mobile Radiographic Equipment

... - Some x-ray tube require a low voltage - The capacitor discharge equipment units have xray tubes which incorporate a grid to switch ...
Chem 133 - Problem Set #1
Chem 133 - Problem Set #1

... Basically, shielding is wrapping wires that carry an analog signal with a grounded conductor. This will help to reduce environmental noise originating from electromagnetic sources such as 120VAC outlets and radio waves. 19. When is it appropriate to use a ‘running’ or ‘boxcar’ average to reduce nois ...
Geen diatitel
Geen diatitel

DC575 - LTC2410CGN Evaluation Kit Quick Start Guide
DC575 - LTC2410CGN Evaluation Kit Quick Start Guide

A comparative assessment of hysteresis and dead beat controllers
A comparative assessment of hysteresis and dead beat controllers

... from measured load currents are classified into two types of compensation techniques [1–4] namely time domain and the frequency domain. In the time domain, the more commonly applied methods are the instantaneous reactive power theory (PQ-theory) and the synchronous reference frame transformation (SR ...
FPA600 600W Thick Film Heatsink Resistors
FPA600 600W Thick Film Heatsink Resistors

... Other terminal dimensions available, contact ARCOL for more information ...
Lecture 13
Lecture 13

a survey and study of different types of pwm
a survey and study of different types of pwm

The Vital Role of Utilities in Providing Transmission Grid Stability
The Vital Role of Utilities in Providing Transmission Grid Stability

... Envisaged developments will change system dynamics, which will require to be proactively studied and mitigation measures put in place – Inter-connecting SAPP and EAPP – Inter-connecting hEdM North and South – Higher penetration of sonlar and wind generation ...
Name: Date:______ Hour:______ Assignment #______ Power and
Name: Date:______ Hour:______ Assignment #______ Power and

... Power and Energy Calculations Use the following formulas below to solve. ...
DANGER! - Macromatic
DANGER! - Macromatic

... Macromatic has obsoleted the PLP208, PLP240, PLP400 & PLP480 single voltage products and replaced all of them with the PLPU, which works on any line-line voltage from 190-500V. The PLPU functions the same and can be used in place of these older products without any special setup. This change is effe ...
Islatrol Series
Islatrol Series

IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... damage to the power system. Despite the favorable aspects grid-connected DGs can provide to the distribution system, a critical demanding concern is islanding detection and prevention. Islanding is a condition where the DG supplies power and is not under the direct control of the utility. Islanding ...
< 1 ... 1013 1014 1015 1016 1017 1018 1019 1020 1021 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.