• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Macro-model Based SPICE Simulation of DC/DC Switching Regulators C. Bunlaksananusorn
Macro-model Based SPICE Simulation of DC/DC Switching Regulators C. Bunlaksananusorn

... Letting the controlled source Eg be equal to V(1-Vin), Req or negative voltage, depending on whether Vc is greater or smaller than Vsaw, is clamped to one and zero respectively becomes by a voltage clamp circuit. Rc and Cc are a very small resistor and capacitor added only to aid simulation (1 − Vin ...
EMC Filters Attenuation Measuring Method
EMC Filters Attenuation Measuring Method

... frequency. Purely resistive circuits such as filament lamps or heaters, when powered from the mains, draw a current that is directly proportional to the applied voltage, and do not create any extra harmonic components. By contrast, non-linear circuits do draw a non-sinusoidal current, despite the ap ...
FPGA based speed control of PMBLDC motor using
FPGA based speed control of PMBLDC motor using

... Fig. 2 Power Circuit topology of a three-phase VSI. The confusion arises because a brushless dc motor does not directly operate of a dc voltage source A PMBLDC motor has a rotor with permanent magnets and a stator with windings. It is essentially a dc motor turned inside out. The brushes and commuta ...
CD35455460
CD35455460

... Figure.1 Three phase two level voltage source inverter Space Vector Modulation (SVM) [1] was originally developed as vector approach to Pulse Width Modulation for three phase inverters. It is a more sophisticated technique for generating sine wave that provides higher voltages with lower total harmo ...
BUT11/ 11A NPN Silicon Transistor Absolute Maximum Ratings
BUT11/ 11A NPN Silicon Transistor Absolute Maximum Ratings

... device or system whose failure to perform can be or (b) support or sustain life, or (c) whose failure to perform reasonably expected to cause the failure of the life support when properly used in accordance with instructions for use device or system, or to affect its safety or effectiveness. provide ...
Calculating power factor
Calculating power factor

... phase angle of near zero. This is no coincidence. Note that the lagging current, IL of the inductor would have caused the total current to have a lagging phase somewhere between (Itotal) and IL. However, the leading capacitor current, IC, compensates for the lagging inductor current. The result is a ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... the shoot-through zero state whereas it is equivalent to open circuit when it is in the traditional zero state. When the two inductors ( L1 and L2 ) are small and approach zero, the Z-Source network reduces to two capacitors ( C1 and C2 ) in parallel and becomes a traditional VSI. Therefore, a VSI’s ...
EE 1231216
EE 1231216

Procedure and Questions
Procedure and Questions

... measured component values. You may assume the capacitor is effectively a short circuit at 10 kHz. Find the percent difference between the predicted and measured input resistance values. ...
Rack Mount Card Cage
Rack Mount Card Cage

... 7 (2-slot) modules. All modules located within the chassis rack are hot-swappable, so that modules can be removed or replaced without powering down the rack. ...
Does R6 need to be a 1210
Does R6 need to be a 1210

... R9 = R10 = 32.4k ohm (value selected for quick startup) Maximum AC input voltage = 253V Maximum peak voltage (Vpk) = maximum possible = 253(√2) = 357.8V Maximum voltage across R9 or R10 = 357.8/2) = 178.9V Minimum package size to handle the voltage is 1206 (from Vishay D/CRCW e3 datasheet) Maximum c ...
Lab 2 - Faculty
Lab 2 - Faculty

... PART V – Questions 1. How is a milliammeter connected to measure current? 2. What precautions must be observed when measuring current? 3. An ohmmeter must never be used to measure resistance in a circuit that is carrying current. ...
G205 Design of Buck Converter For Photovoltaic System Applications
G205 Design of Buck Converter For Photovoltaic System Applications

... potential of solar energy as an alternative energy to replace fossil energy is increasingly scarce and expensive. Utilization of solar energy need photovoltaic that will convert solar energy into DC electricity. Advantages of photovoltaic are unlimited energy source, non- pollution, environmentally ...
CKX150 Specifications
CKX150 Specifications

Super Switch - Nishant Power Solutions
Super Switch - Nishant Power Solutions

... Guaranteed transfer to alternate source within -10to -15%of vnaminal · Maximum continuous status 25A, 50HZ · Load power factor range Up to 3.5 · In-Phase transfer window Adjustable from 7.5 +/· source voltage distortion Up to 10% THD · Overload capability 125% of continuous current for 2 hrs, 1000% ...
DMS-20RM Series - Murata Power Solutions
DMS-20RM Series - Murata Power Solutions

... 1. Measurement Type: DMS-20RM series ac voltmeters employ a precision rms-to-dc converter and a high-precision voltage reference to measure and display the rms value of complex ac waveforms. Please note, the rear-mounted potential transformer is used to isolate the input signal being measured (TB2) ...
Single Stage 800 mA Converter with High Power Factor
Single Stage 800 mA Converter with High Power Factor

... isolated power stage is that the feedback loop must have narrow bandwidth (< 40 Hz) otherwise the power factor would be low (capacitor C8 sets the bandwidth). As a consequence, the 120 Hz line ripple is propagated to the output and can only be filtered by the output capacitance. In this example 2,00 ...
In radio and television broadcasting (as well as in amateur radio) the
In radio and television broadcasting (as well as in amateur radio) the

Doubly Fed Induction Generator for Wind Energy Conversion
Doubly Fed Induction Generator for Wind Energy Conversion

... both active and reactive powers has achieved by RSC control. DFIG has also been verified at wind turbine stalling condition for compensating harmonics and reactive power of local loads. Proposed DFIG-based WECS with an integrated active filter has been simulated using MATLAB/Simulink environment, an ...
RESONANT TRANSFORMER
RESONANT TRANSFORMER

... disappears and the voltage across the test object collapse. This reduces chances of partial failure leading to complete failure i.e. no repeated flashovers occur in case of partial failures of the test object and insulation recovery. • Disadvantages of Resonant transformer: (1) Choke: The requiremen ...
UNISONIC TECHNOLOGIES CO., LTD TL084
UNISONIC TECHNOLOGIES CO., LTD TL084

... Gain-of-10 Inverting Amplifier ...
Introduction to Digital Multimeters
Introduction to Digital Multimeters

... resistance is called a multimeter, As voltage is always relative between two points, a voltage-measuring meter ("voltmeter") must be connected to two points in a circuit in order to obtain a good reading. Be careful not to touch the bare probe tips together while measuring voltage, as this will crea ...
Slides, chapter 20 - University of Colorado Boulder
Slides, chapter 20 - University of Colorado Boulder

Alternating Current - Goodheart
Alternating Current - Goodheart

... the United States is based upon the 60 Hz frequency standard. ...
2014 RA420 PEMC2014 135-Ozsoy
2014 RA420 PEMC2014 135-Ozsoy

... because of several advantages summarized in introduction. Robustness of the system is essential due to direct connection of stator windings to the grid. This study demonstrated a novel current controller which is robust against machine parameter variations. Experimental results obviously show decoup ...
< 1 ... 998 999 1000 1001 1002 1003 1004 1005 1006 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.