PU500-series 400 to 500 W
... We use the EMC product standard ”Low voltage power supplies DC output” EN 61204-3 as base for measurement principles. The Immunity EMC levels are elevated in order to comply to EN 50121-3-2 (IEC 62236-3-2) Railway application: Rolling stock – Apparatus, and EN 50121-4 (IEC 62236-4) Railway applicati ...
... We use the EMC product standard ”Low voltage power supplies DC output” EN 61204-3 as base for measurement principles. The Immunity EMC levels are elevated in order to comply to EN 50121-3-2 (IEC 62236-3-2) Railway application: Rolling stock – Apparatus, and EN 50121-4 (IEC 62236-4) Railway applicati ...
MAX9156 Low-Jitter, Low-Noise LVPECL-to-LVDS Level Translator in an SC70 Package General Description
... Each line of a differential LVPECL link should be terminated through 50Ω to VCC - 2V or be replaced by the Thevinin equivalent. The LVDS output voltage level depends upon the differential characteristic impedance of the interconnect and the value of the termination resistance. The MAX9156 is guarant ...
... Each line of a differential LVPECL link should be terminated through 50Ω to VCC - 2V or be replaced by the Thevinin equivalent. The LVDS output voltage level depends upon the differential characteristic impedance of the interconnect and the value of the termination resistance. The MAX9156 is guarant ...
COULOMB METER - Digital
... By definition, one Coulomb is the quantity of electricity equivalent to 1x amp second (one amp flowing for exactly one second). The amount of charge on an electron inside an atom is 1.602 x 10-19 Coulombs. The Coulomb Meter can measure up to 1,999 nC (nanoCoulombs). Note: 1x nC = 10-9 Coulombs. In t ...
... By definition, one Coulomb is the quantity of electricity equivalent to 1x amp second (one amp flowing for exactly one second). The amount of charge on an electron inside an atom is 1.602 x 10-19 Coulombs. The Coulomb Meter can measure up to 1,999 nC (nanoCoulombs). Note: 1x nC = 10-9 Coulombs. In t ...
Insulator testing set for finding the efficiency in Ozone generator
... insulators namely solid, fluid and gas for choosing the best electric insulators. In order to generate the ozone gas, the insulator must be selected in electrode set. Nowadays, the insulators do not have the optimal test procedure for getting total efficiency. Therefore, in this paper, a design of o ...
... insulators namely solid, fluid and gas for choosing the best electric insulators. In order to generate the ozone gas, the insulator must be selected in electrode set. Nowadays, the insulators do not have the optimal test procedure for getting total efficiency. Therefore, in this paper, a design of o ...
HMC723LC3C 数据资料DataSheet下载
... allows for negative-edge triggered applications. The HMC723LC3C also features an output level control pin, VR, which allows for loss compensation or for signal level optimization. All input signals to the HMC723LC3C are terminated with 50 Ohms to ground on-chip, and maybe either AC or DC coupled. Th ...
... allows for negative-edge triggered applications. The HMC723LC3C also features an output level control pin, VR, which allows for loss compensation or for signal level optimization. All input signals to the HMC723LC3C are terminated with 50 Ohms to ground on-chip, and maybe either AC or DC coupled. Th ...
Rectifiers
... devices are like one-way valves, they allow current to only flow in one direction. If a current tries to flow in the opposite direction, it is stopped by the diode. If you look at an AC waveform, you see a sine-wave shape with one portion of the wave on the positive side of the y-axis and one side ...
... devices are like one-way valves, they allow current to only flow in one direction. If a current tries to flow in the opposite direction, it is stopped by the diode. If you look at an AC waveform, you see a sine-wave shape with one portion of the wave on the positive side of the y-axis and one side ...
OPA551 OPA552 High-Voltage, High-Current OPERATIONAL AMPLIFIERS
... the full operating voltage range. Parameters that vary significantly with operating voltage are shown in the Typical Performance Curves. For applications that do not require symmetrical output voltage swing, power supply voltages do not need to be equal. The OPA551 and OPA552 can operate with as lit ...
... the full operating voltage range. Parameters that vary significantly with operating voltage are shown in the Typical Performance Curves. For applications that do not require symmetrical output voltage swing, power supply voltages do not need to be equal. The OPA551 and OPA552 can operate with as lit ...
PAM2327 Description Pin Assignments
... Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Inc ...
... Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Inc ...
Data Sheet
... is not used, especially in noisy environments. This can most easily be done by connecting a resistor between VIN and the EN pin. The resistor is required, since the internal zener diode, at the EN pin, will conduct for voltages above about 6V. The current in this zener must be limited to less than 1 ...
... is not used, especially in noisy environments. This can most easily be done by connecting a resistor between VIN and the EN pin. The resistor is required, since the internal zener diode, at the EN pin, will conduct for voltages above about 6V. The current in this zener must be limited to less than 1 ...
Voltage and Current harmonics caused by Power Factor
... by adding a capacitor. Capacitors including non-linear load, so that the addition of the capacitor causing an increase in nonlinear loads. Nonlinear load provides output waveform that is not linear, causing the current waveform and the output voltage is not the same as the input waveform (distorted) ...
... by adding a capacitor. Capacitors including non-linear load, so that the addition of the capacitor causing an increase in nonlinear loads. Nonlinear load provides output waveform that is not linear, causing the current waveform and the output voltage is not the same as the input waveform (distorted) ...
High-Voltage, High-Current OPERATIONAL AMPLIFIER DESCRIPTION FEATURES
... behavior remains unchanged throughout the full operating voltage range. Parameters which vary significantly with operating voltage are shown in the typical characteristic curves. Some applications do not require equal positive and negative output voltage swing. Power-supply voltages do not need to b ...
... behavior remains unchanged throughout the full operating voltage range. Parameters which vary significantly with operating voltage are shown in the typical characteristic curves. Some applications do not require equal positive and negative output voltage swing. Power-supply voltages do not need to b ...
University of Northern British Columbia Physics Program Physics 101 Laboratory Manual
... Theory - The theory on which the experiment is based. This usually includes an equation which is to be verified. Be sure to clearly define the variables used and explain the significance of the equation. (In ink) Apparatus - A brief description of the important parts and how they are related. In all ...
... Theory - The theory on which the experiment is based. This usually includes an equation which is to be verified. Be sure to clearly define the variables used and explain the significance of the equation. (In ink) Apparatus - A brief description of the important parts and how they are related. In all ...
11. DC/AC Inverters (optional) - CleanEnergy Solutions International
... The solar (PV) system referred to in this document is perceived to be the dominant type of system in the local market in the next decade or so. Typically called the solar home system (SHS), it operates at a nominal voltage of 12 V DC. An SHS intends to provide the user with a convenient means of sup ...
... The solar (PV) system referred to in this document is perceived to be the dominant type of system in the local market in the next decade or so. Typically called the solar home system (SHS), it operates at a nominal voltage of 12 V DC. An SHS intends to provide the user with a convenient means of sup ...
MAX5402 256-Tap, µPoT, Low-Drift, Digital Potentiometer General Description
... The MAX5402 consists of 255 fixed resistors in series between pins H and L. The potentiometer wiper (pin W) can be programmed to access any one of the 256 different tap points on the resistor string. The MAX5402 has an SPI-compatible 3-wire serial data interface to control the wiper tap position. Th ...
... The MAX5402 consists of 255 fixed resistors in series between pins H and L. The potentiometer wiper (pin W) can be programmed to access any one of the 256 different tap points on the resistor string. The MAX5402 has an SPI-compatible 3-wire serial data interface to control the wiper tap position. Th ...
tayyab here
... which in turn causes losses in the transmission and distribution system. Due to increase in losses in distribution system, the line voltage at remote areas will decreases. Due to advancements in power electronic converters to maintain the load voltage as constant equipment like DVR, D-STATCOM are us ...
... which in turn causes losses in the transmission and distribution system. Due to increase in losses in distribution system, the line voltage at remote areas will decreases. Due to advancements in power electronic converters to maintain the load voltage as constant equipment like DVR, D-STATCOM are us ...
MAX4684/MAX4685 0.5Ω/0.8Ω Low-Voltage, Dual SPDT Analog
... Note 1: Signals on NO_, NC_, and COM_ exceeding V+ or GND are clamped by internal diodes. Limit forward-diode current to maximum current rating. Note 2: This device is constructed using a unique set of packaging techniques that impose a limit on the thermal profile the device can be exposed to durin ...
... Note 1: Signals on NO_, NC_, and COM_ exceeding V+ or GND are clamped by internal diodes. Limit forward-diode current to maximum current rating. Note 2: This device is constructed using a unique set of packaging techniques that impose a limit on the thermal profile the device can be exposed to durin ...
A Second Long Pulse Modulator For TESLA Using IGBTs
... to the interconnection and other inductances. The maximum level that we expect the switch to see is 12.5 kV. Since we use the back-up IGBTs at one half voltage level in normal operation, there are 13.5 devices sharing this voltage, with 925 V per IGBT. If we add to this an expected 80 V imbalance du ...
... to the interconnection and other inductances. The maximum level that we expect the switch to see is 12.5 kV. Since we use the back-up IGBTs at one half voltage level in normal operation, there are 13.5 devices sharing this voltage, with 925 V per IGBT. If we add to this an expected 80 V imbalance du ...
active power filters based on a single current measurement system
... suitable switching rules [9]-[13]. However, with any type of current regulator, two current measurement systems are usually employed to sense the load and filter currents. Furthermore, powerful microprocessors are necessary for the on-line evaluation of the harmonic content of the load current. In t ...
... suitable switching rules [9]-[13]. However, with any type of current regulator, two current measurement systems are usually employed to sense the load and filter currents. Furthermore, powerful microprocessors are necessary for the on-line evaluation of the harmonic content of the load current. In t ...