• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
VRP-3000-5000, 230V, 50Hz
VRP-3000-5000, 230V, 50Hz

... The low-weight, high efficiency VRp is easy to install in any environment. The automatic bypass assures that connected equipment will not shut down, even if VRp fails. VRp is compatible with all loads as it does not switch any components in the power path. VRp’s ultra-low impedance assures stability ...
"Improved Start-up Performance for Charge Pumps TPS6030x"
"Improved Start-up Performance for Charge Pumps TPS6030x"

Problem Set 4
Problem Set 4

... Design a dc ammeter with an Ayrton Shunt using a 50 A PMMC meter movement with internal resistance 3 k. The ammeter is to have three ranges: 100 A; 1mA; and 10 mA. (b) Comment on the following statement: “An ammeter using an Ayrton Shunt requires a make-before-break selection switch” ...
LAB 2 Circuit Tools
LAB 2 Circuit Tools

... a red indicator light will light up: green indicates normal (constant voltage) operation and red indicates the current limit has been reached. • Use the coarse and fine adjust knobs to vary the output voltage. What is the maximum voltage? How big is the adjustment range of the fine adjusting knob? • ...
word
word

... (2) Apply a 1kHz sinusoidal signal of about 200mV amplitude (from the function generator) to each input separately with the other grounded and measure the sign and magnitude of the amplification factor. (3) Then connect the same signal to both inputs (i.e. make va = vb = vin) and measure the output ...
lecture7
lecture7

... • The system is linear if it possesses the superposition property. Let y1 (t ) be the response of a continuous - time system to an input x 1 (t ), and let y 2 (t ) be the output correspond ing to the input x 2 (t ). System is linear if : 1) The response to x1 (t )  x2 (t ) is y1 (t )  y2 (t ). 2)T ...
Parallel Circuits Worksheet File
Parallel Circuits Worksheet File

... Circle the best term in the parentheses to correctly complete each statement. 1. A parallel circuit has (only one, more than one) path for current to travel. 2. Two different resistors are connected in parallel. The current through one of the resistors will be (equal to, different from) the current ...
hw9soln
hw9soln

Some physical problems: The driven, damped, harmonic oscillator
Some physical problems: The driven, damped, harmonic oscillator

... 2) Set up the resistor and capacitor in series as shown and measure the magnitude and phase shift of the voltage across the capacitor as a function of frequency from 10Hz to 106 Hz. Take data on a 1-2-5-10 scale in frequency. For each frequency, you should also measure the voltage out of the functio ...
Product Data Sheet: DEHNconnect SD2 DCO SD2 MD HF 5 (917 970)
Product Data Sheet: DEHNconnect SD2 DCO SD2 MD HF 5 (917 970)

Mar 2008 - Tiny, Fast and Efficient Comparator Regenerates Clock Signals up to 3MHz
Mar 2008 - Tiny, Fast and Efficient Comparator Regenerates Clock Signals up to 3MHz

... The LTC6702’s push-pull output stage and its ability to operate with either input above the positive supply rail simplifies logic level translation. Many comparators use an open collector or open drain type output stage to enable ...
14 i Energy Meters (kWh Meters)
14 i Energy Meters (kWh Meters)

... as DC systems. The panel mounting kWh meters are accurate to class 1 to IEC1036 and AC models have a user selectable CT ratio through a rotary switch accessible from a removable cover on the meter. The meters are housed in a compact DIN96 enclosure measuring only 61mm in depth and are available comb ...
Energy Efficient and High Performance Current-Mode Neural
Energy Efficient and High Performance Current-Mode Neural

... The schematic of the SAR logic consists of shift register and code shift register using D-flip flop as shown in figure ix. Initially the reset line goes low. This line controls set line of FF1 and reset lines of all other sequencer flip flops. The same reset signal also controls the reset line of c ...
MASTER INSTRUMENT CORPORATION  SINGLE-PHASE BRIDGE RECTIFIER RB151 THRU RB157
MASTER INSTRUMENT CORPORATION SINGLE-PHASE BRIDGE RECTIFIER RB151 THRU RB157

... l Ideal for printed circuit board l High isolation voltage from case to leads l High temperature soldering guaranteed: 260 oC/10 second, at 5 lbs. (2.3kg) tension. ...
Low Power Low Offset Voltage Single Comparator
Low Power Low Offset Voltage Single Comparator

... Low input offset voltage: 3 mV typ. Input common-mode voltage range includes ...
MMV1S0505SC Datasheet
MMV1S0505SC Datasheet

... Murata Power Solutions MMV1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The MMV1 has been recognized by ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... be connected to VDD very close to the two ICs. In most cases, the final output of the op amp (–VREF) will be heavily decoupled, which means that the op amp selected must be stable with large capacitive loads. A typical decoupling network consists of a 1 µF to 10 µF electrolytic capacitor in paralle ...
uninterruptible power supply
uninterruptible power supply

07-NileshJoshi
07-NileshJoshi

... System is said to be causal if the present value of the output signal depends only on the present and or the past value of the input signal. Such a system is often referred to as being nonanticipatory, as the output doesn’t anticipate future value of the input. The if the resistor and capacitor are ...
The Linear Variable Differential Transformer (LVDT)
The Linear Variable Differential Transformer (LVDT)

... When the armature is moved from one end to the other through the centre position the output voltages changes from maximum to zero and back to maximum again but in the process changes its phase angle by 180 deg’s. This enables the LVDT to produce an output AC signal whose magnitude represents the am ...
UDN2998 - Allegro MicroSystems
UDN2998 - Allegro MicroSystems

... Exact body and lead configuration at vendor’s option within limits shown. Lead gauge plane is 0.762 mm below seating plane. Supplied in standard sticks/tubes of 15 devices. ...
Common Base, Common Emitter, and Common Collector
Common Base, Common Emitter, and Common Collector

... In this experiment, two Common Collector Amplifier circuits were built. The first circuit in Figure 9.11 consisted of a Common Collector Amplifier with an open-circuit as its output. A coupling capacitor was connected to the input. The open-circuit voltage gain, input resistance, and output resistan ...
DESIGN-AND-SIMULATION-OF-DIFFERENT
DESIGN-AND-SIMULATION-OF-DIFFERENT

... Phase Frequency Detector (PFD) is one of the PLL blocks. The main concept of PFD is comparing two input frequencies in terms of both phase and frequency [1]. In a PLL the two frequencies are reference frequency (Fref) and the voltage controlled oscillator (VCO) output after division by N (Fvco). The ...
439QS16GE - Hittite Microwave Corp.
439QS16GE - Hittite Microwave Corp.

LF351 WIDE-BANDWIDTH JFET-INPUT OPERATIONAL AMPLIFIER
LF351 WIDE-BANDWIDTH JFET-INPUT OPERATIONAL AMPLIFIER

... NC – No internal connection ...
< 1 ... 598 599 600 601 602 603 604 605 606 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report