• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SYNCHRONOUS PROGRAMMABLE 4
SYNCHRONOUS PROGRAMMABLE 4

P S C
P S C

Flash ADC Lab
Flash ADC Lab

... Name:________________ ...
Ohm’s Law - City University of New York
Ohm’s Law - City University of New York

Digital Engineering - The Random Information Bureau
Digital Engineering - The Random Information Bureau

Functions Batch Controller–Presetable Counter DigiFlow 514
Functions Batch Controller–Presetable Counter DigiFlow 514

ECE 1020 FINAL PRESENTATION
ECE 1020 FINAL PRESENTATION

... Not realizing that holding the sensor at different angles would impact our values Establishing a constant way to measure the distances and hold the arduino/sensor combination ...
Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

PM3000W
PM3000W

... Advanced Grid Compatibility The PM3000W is an intelligent and highly integrated power converter. It meets the demanding needs of wind power applications and features advanced grid compatibility control. Its a compact package design that yields a very high power density of up to 130 W/in.³ (7.9 W/cm³ ...
UNIVERSITY OF MASSACHUSETTS DARTMOUTH
UNIVERSITY OF MASSACHUSETTS DARTMOUTH

... The principle of Superposition states that the total response of a linear circuit excited by more than one independent source can be represented as the algebraic sum of the responses to each source applied individually. In this experiment, you will determine the voltage across and the current throug ...
ppt
ppt

Theoretical Design
Theoretical Design

... Acquisition Software Project Record). Instead of outputting data on pulse height and width, the circuit only needs to output a “yes or no” signal as to if there was a pulse or not. The circuit is designed to accomplish this by using an op amp comparator to distinguish between the pulse signal in the ...
VM1AT-R1 - Instructions
VM1AT-R1 - Instructions

... changing anything (you may need to retouch the converter’s trimpot to keep the output in the 4.75 to 5.35 V. range).  INPUT LOGIG LEVEL. The nominal input voltage for the Digital Inputs is 24 Vdc. This voltage is reduced to 5V with a resistor divider using a 39K/10K resistors per input. By changing ...
Physics 517/617 Experiment 1 Instrumentation and Resistor Circuits
Physics 517/617 Experiment 1 Instrumentation and Resistor Circuits

You Thought You Knew Analog-----------------------------------
You Thought You Knew Analog-----------------------------------

... often involve distortion that changes in a step-like manner at a certain level. This is because the internal circuits (PMOS and NMOS input differential stages) are switched based on the input voltage in conventional full-swing CMOS opamps. As a result, opamps have been recently introduced that enabl ...
3) Schmitt Trigger (20 Points)
3) Schmitt Trigger (20 Points)

MGJ6 Series www.murata-ps.com 5.2kVDC Isolated 6W SM DC/DC Converters
MGJ6 Series www.murata-ps.com 5.2kVDC Isolated 6W SM DC/DC Converters

... ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrit ...
DC1384 - LTC2452CDDB Evaluation Kit Quick Start Guide
DC1384 - LTC2452CDDB Evaluation Kit Quick Start Guide

... 16 bit high performance differential ∆Σ analog-todigital converter (ADC) with an SPI interface. The input is bipolar with a range of Ref-to Ref+. The modulator’s proprietary sampling technique reduces the average input current to less than 50nA – orders of magnitude lower than typical delta sigma AD ...
skynet electronic specification m/n : snp-z106
skynet electronic specification m/n : snp-z106

... The efficiency is higher than 80% typ . while measuring at nominal line and rated load. 4.2 Hold up time The hold up time is longer than 16mS at 115VAC input and rated load , which is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage. 4.3 Prote ...
Download FPS Datasheet
Download FPS Datasheet

... Long-time overcurrent provides thermal protection for feeder or load Coordination using IEEE and IEC Curves Instantaneous overcurrent to detect catastrophic failure ...
Functions Batch Controller–Presetable Counter DigiFlow 514
Functions Batch Controller–Presetable Counter DigiFlow 514

... Since the DigiFlow 514 scaleable integrates any physical unit which is converted into 4-20mA analog or frequency signal, the user have to enter a dimension text with up to 5 characters length. ...
The circuit in this problem has two resistors, one capacitor,... The power supply is a sinusoidal voltage source with an...
The circuit in this problem has two resistors, one capacitor,... The power supply is a sinusoidal voltage source with an...

... The circuit in this problem has two resistors, one capacitor, and one inductor. The power supply is a sinusoidal voltage source with an amplitude of 4 volts and a frequency of 3,000 radians per second. We want to find the apparent power absorbed by the load in the circuit. If we can find the voltage ...
Chapter 12
Chapter 12

1B22 数据手册DataSheet 下载
1B22 数据手册DataSheet 下载

... The 1B22 is an isolated voltage-to-current converter that incorporates transformer isolation to achieve high performance and automated surface mount manufacturing for low cost and increased reliability. Designed for industrial applications, it is especially suited for harsh environments with extreme ...
Automotive Electronics Product Information Lambda Probe Interface
Automotive Electronics Product Information Lambda Probe Interface

... Nernst cell reference voltage (450mV) Inverting input of pump current amplifier (shunt voltage) Non inverting input of pump current amplifier and output of the pump current control Output of pump current amplifier (-> external filter) Input of lambda output amplifier (after external filter) Output o ...
< 1 ... 597 598 599 600 601 602 603 604 605 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.